• Title/Summary/Keyword: distribution System

Search Result 15,353, Processing Time 0.046 seconds

Reliability Calculation of Distribution System including Photovoltaics Generation (태양광 발전이 도입된 배전계통에서 날씨효과를 고려한 신뢰도 산정)

  • Bae, In-Su;Lee, Il-Ryong;Lee, Jun-Kyoung;Shim, Hun;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.100-102
    • /
    • 2003
  • This paper describes a time-sequential simulation technique for the reliability evaluation of a distribution system including Photovoltaics(PV) Generation. A three-state model of a PV is presented, considering variable radiation and the forced outage rate. A test distribution system is utilized to illustrate the proposed model. The effects on the distribution system reliability of the PV parameters are examined and illustrated.

  • PDF

Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line (초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

Analysis of Recloser-Fuse Coordination in Distribution System with SFCL (배전계통에 초전도 전류계한기 적용 시 Recloser-Fuse 협조 분석)

  • Kim, Myoung-Hoo;Kim, Jin-Seok;You, Il-Kyoung;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Ahn, Jae-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.432-435
    • /
    • 2009
  • This paper shows us the basic protective devices to protect against fault current such as recloser and fuse. Also recloser has been coordinated with fuse in distribution system to protect against fault current efficiently. However, in distribution system with SFCL, recloser-fuse coordination could be different to now and fault current couldn't be clear, if occurred. Therefore, this paper analysed recloser-fuse coordination in distribution system with SFCL using PSCAD/EMTDC

  • PDF

Back Tracing Calculation Method for the Leakage Detection in Water Distribution System (상수관망에서 누수탐지를 위한 역추적계산법)

  • Kwon, Hyuk Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

A Study on the Internet Spatial Data Electronic Distribution System (인터넷 공간데이타 전자유통 시스템에 관한 연구)

  • 이기영;서의석;이용수
    • Journal of the Korea Society of Computer and Information
    • /
    • v.5 no.3
    • /
    • pp.40-45
    • /
    • 2000
  • Recently. the advent of WWW increased the population of internet users and many institutions are carrying out technical development research to implement spatial data distribution environment via internet because importance of Web Geographic Information System(WGIS) is being increased highly. To be accessed WGIS data, we need Spatial Data Electronic Distribution System(SDEDS) which registers and sell spatial data in WWW. In this paper, we Propose and design effective SDEDS to expel spatial data electronic distribution system which is connected WWW. Therefore, we show how to implement and functions of each module.

  • PDF

A Study on Energy Savings of a DC-based Variable Speed Power Generation System (직류기반 가변속 발전 시스템을 이용한 에너지 절감에 관한 연구)

  • Kido Park;Gilltae Roh;Kyunghwa Kim;Changjae Moon;Jongsu Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.666-671
    • /
    • 2023
  • As international environmental regulations on ship emissions are gradually strengthened, interest in electric propulsion and hybrid propulsion ships is increasing, and various solutions are being developed and applied to these ships, especially stabilization of the power system and system efficiency. The direct current distribution system is being applied as a way to increase the power. In addition, verification and testing of safety and performance of marine DC distribution systems is required. As a result of establishing a DC distribution test bed, verifying the performance of the DC distribution (variable speed power generation) system, and analyzing fuel consumption, this study applied a variable speed power generation system that is applied to DC power distribution for ships, and converted the power output from the generator into a rectifier. A system was developed to convert direct current power to connect to the system and monitor and control these devices. Through tests using this DC distribution system, the maximum voltage was 751.5V and the minimum voltage was 731.4V, and the voltage fluctuation rate was 2.7%, confirming that the voltage is stably supplied within 3%, and a variable speed power generation system was installed according to load fluctuations. When applied, it was confirmed through testing that fuel consumption could be reduced by more than 20% depending on the section compared to the existing constant speed power generation system.

A Study on the Coordination Control Algorithm of Step Voltage Regulator and Battery Energy Storage System for Voltage Regulation in Distribution System (배전계통의 전압안정화를 위한 선로전압조정장치와 전지전력저장장치의 협조제어 알고리즘에 관한 연구)

  • Kim, Byung-Ki;Wang, Jong-Yong;Park, Jea-Bum;Choi, Sung-Sik;Ryu, Kyung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.269-278
    • /
    • 2016
  • In order to maintain customer voltages within allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) installed in distribution system is very important, considering the scheduled delay time(30 sec) of SVR. However, the compensation of BESS(Battery Energy Storage System) during the delay time of SVR is being required because the customer voltages in distribution system interconnected with PV(Photovoltaic) system have a difficultly to be kept within allowable limit. Therefore, this paper presents the optimal voltage stabilization method in distribution system by using coordination operation algorithm between BESS and SVR. It is confirmed that customer voltage in distribution system can be maintained within allowable limit($220{\pm}13V$).

PC Cluster Based Parallel Genetic Algorithm-Tabu Search for Service Restoration of Distribution Systems (PC 클러스터 기반 병렬 유전 알고리즘-타부 탐색을 이용한 배전계통 고장 복구)

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.375-387
    • /
    • 2005
  • This paper presents an application of parallel Genetic Algorithm-Tabu Search (GA-TS) algorithm to search an optimal solution of a service restoration in distribution systems. The main objective of service restoration of distribution systems is, when a fault or overload occurs, to restore as much load as possible by transferring the do-energized load in the out of service area via network reconfiguration to the appropriate adjacent feeders at minimum operational cost without violating operating constraints, which is a combinatorial optimization problem. This problem has many constraints with many local minima to solve the optimal switch position. This paper develops parallel GA-TS algorithm for service restoration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solutions of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper $10\%$ of the population to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC cluster system consists of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the validity of the proposed method, proposed algorithm has been tested with a practical distribution system in Korea. From the simulation results, we can find that the proposed algorithm is efficient for the distribution system service restoration in terms of the solution quality, speedup, efficiency and computation time.

Manufacture of Water-Resistant Corrugated Fiberboard Boxes for Agricultural Products in the Cold Chain System (IV) - Measurement and analysis of storage condition, distribution route, and packaging method for selected agricultural products - (농산물 저온유통용 내수골판지 상자의 제조(제4보) - 대상농산물별 저온유통조건, 유통경로 및 포장규격 조사 분석 -)

  • Lee Myoung-Hoon;Jo Jung-Yeon;Min Choon-Ki;Shin Jun-Seop
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.62-69
    • /
    • 2006
  • This study was carried out to measure and analyze the storage condition, distribution route, and packaging method of four selected agricultural products(small tomato, cabbage, peach, and carrot) in the cold chain system. It was shown that dew-forming phenomenon by fruits and vegetables deteriorates the agricultural product quality and physical properties of corrugated fiberboard box during the cold chain system. The compressive strength deterioration in corrugated fiberboard boxes was much greater for single wall(SW) corrugated fiberboard containers than for double wall(DW) in low temperature-high humidity condition. To reduce the deterioration of box and dew-forming phenomenon, water-repellency treatment should be over $R_6$. However, water-resistant treatment of corrugated fiberboard containers would be effective under high relative humidity conditions more than 75% RH. It was suggested that functional corrugated fiberboard box packaging would be an optimum method to reduce the deterioration of agricultural products quality by. It was also achieved controlling the relative humidity and temperature during the storage and physical distribution process.

An Experimental Study on Droplet Size according to Discharge Coefficient of Sprinkler Head (스프링클러 헤드의 방수상수에 따른 물방울 크기에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • The sprinkler system is a basic fire extinguishing system that uses water as an extinguishing agent. In order to evaluate the fire extinguishing performance of the sprinkler system, information such as the discharge angle, discharge speed, discharge pressure, flow rate, and water droplet size of the installed head are required. However, there is a lack of research on droplets size compared to other requirements. In this study, to evaluate the extinguishing characteristics of sprinkler system, the droplet size distribution was measured for various types of sprinkler heads actually used. The size of the droplet was measured using laser diffraction method. The 50% cumulative volume distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the Rosin-Rammler index value are presented. As a result of the fire simulation with FDS, it was confirmed that the performance difference occurs according to the water droplet size distribution even when the same amount of water is used. Therefore, the extinguishing performance of the sprinkler system should be evaluated considering the droplet size distribution according to the sprinkler head type.