• Title/Summary/Keyword: dissipation test

Search Result 752, Processing Time 0.022 seconds

Effect of cumulative seismic damage to steel tube-reinforced concrete composite columns

  • Ji, Xiaodong;Zhang, Mingliang;Kang, Hongzhen;Qian, Jiaru;Hu, Hongsong
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.179-199
    • /
    • 2014
  • The steel tube-reinforced concrete (ST-RC) composite column is a novel type of composite column, consisting of a steel tube embedded in reinforced concrete. The objective of this paper is to investigate the effect of cumulative damage on the seismic behavior of ST-RC columns through experimental testing. Six large-scale ST-RC column specimens were subjected to high axial forces and cyclic lateral loading. The specimens included two groups, where Group I had a higher amount of transverse reinforcement than Group II. The test results indicate that all specimens failed in a flexural mode, characterized by buckling and yielding of longitudinal rebars, failure of transverse rebars, compressive crushing of concrete, and steel tube buckling at the base of the columns. The number of loading cycles was found to have minimal effect on the strength capacity of the specimens. The number of loading cycles had limited effect on the deformation capacity for the Group I specimens, while an obvious effect on the deformation capacity for the Group II specimens was observed. The Group I specimen showed significantly larger deformation and energy dissipation capacities than the corresponding Group II specimen, for the case where the lateral cyclic loads were repeated ten cycles at each drift level. The ultimate displacement of the Group I specimen was 25% larger than that of the Group II counterpart, and the cumulative energy dissipated by the former was 2.8 times that of the latter. Based on the test results, recommendations are made for the amount of transverse reinforcement required in seismic design of ST-RC columns for ensuring adequate deformation capacity.

Characteristics of the Natural Fiber Drain Board for Environmentally Friendly Soil Improvement Method (자연친화형 연약지반개량공법을 위한 천연섬유배수재의 특성 연구)

  • Kim, Ju Hyong;Cho, Sam-Deok;Jang, Yeon-Su;Kim, Soo Sam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • The recent environmental protection issue has diminished the supply of sand for soft ground improvements so much that the prices of sand have shown a sudden rise. Plastic material is one of substitutes for sand material, but plastic is nonperishable and doubtable if it has potential environmental hormone disrupting substances. Moderate-priced natural fiber drain board made with coconut coir and jute filter are in the spotlight recently as an alternative material for sand and plastic drain board etc. Natural fiber drain has not only competitive price but also a characteristic of assimilation into the soils after finishing of its own function. Discharge capacity of the fiber drain board evaluated by triaxial type discharge capacity test was relatively lower than that of plastic drain board. Nevertheless, settlement and pore pressure dissipation behaviors of the fiber drain board and the plastic drain board which were installed in the clayey soil during the composite discharge capacity test were almost similar. It was also found that biodegradation of the fiber drain board was in progress until 18 month after installation in the clayey soil, but they had still enough engineering properties to use at field.

Comparison between Soil Drainage Experiment and Finite Element Analysis for Air Diffusion in Multiphase Porous Media (다공성 매질내의 공기압 확산에 대한 실내 배수시험과 유한요소해석 비교분석)

  • Kim, You-Seong;Kim, Jae-Hong;Kim, Tae-Heon;Lee, Jin-Kwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.77-85
    • /
    • 2014
  • The paper presents comparison between numerical and experimental results to verify finite element algorithm of air diffusion in three-phase porous media. The theory of two-phase flow in partially saturated soil is a fundamental study to predict the safety for $CO_2$ sequestration. Geotechnical engineering problems exposed to atmospheric pressure generally assume that air pressure is equal to zero in three-phase porous media, but the geotechnical engineering problem at a depth of about over 1 km needs to be considered in connection with deformable solid skeleton due to air pressure. Therefore, the objective of this study is to validate the numerical algorithm by comparing with results obtained from measurement of air diffusion and dissipation through drainage test.

Seismic Performance of Non-ductile Reinforced Concrete Frames with Precast ECC Wall Panels (프리캐스트 ECC 벽판으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진성능)

  • Kim, Ji-Hyeon;Jo, Seong-Pill;Seo, Soo-Yeon;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.105-112
    • /
    • 2019
  • This study was conducted to examine experimentally the seismic performance of non-ductile reinforced concrete (RC) frames retrofitted with precast(PC) engineered cementitious composite (ECC) wall panels. The seismic performance was investigated through cyclic load tests on RC frame with different aspect ratio (hw/lw = 2 and 3) and installation position (center and both side of RC frame) of the PC ECC wall panels. Test results indicated that the seismic strengthening method using PC ECC wall panels is effective to improve significantly the strength, stiffness and energy dissipation capacity of non-ductile RC frame. Based on test results, it can be recommended to install PC ECC wall panel at the center of RC frame for improving the strength and to install slender wall panels at both side of RC frame for increasing ductility.

Seismic Performance of Beam-Column Connections for Special Moment Frame Using 600 MPa Flexural Reinforcement (600 MPa 휨 철근을 사용한 특수 모멘트 골조의 보-기둥 접합부의 내진성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Choi, Won-Seok;Chung, Lan;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.591-601
    • /
    • 2011
  • An experimental study was performed to evaluate the seismic performance of beam-column connections using 600 MPa re-bars for beam flexural reinforcement. Three full scale specimens of interior beam-column connection and two specimens of exterior beam-column connection were tested under cyclic loading. The specimens were designed to satisfy the requirements of Special Moment Frame according to current design code. The structural performance of the specimens with 600 MPa re-bar were compared with that of the specimen with 400 MPa re-bars. The test results showed that bond-slip increased in the beam-column joint. However, the load-carrying capacity, deformation capacity, and energy dissipation capacity of the specimens with 600 MPa re-bar were comparable to those of the specimens with 400 MPa re-bars.

Consolidation Characteristics of Soft Ground with Artesian Pressure (피압에 따른 연약지반의 압밀 거동)

  • Yun, Daeho;Kim, Jaehong;Kim, Yuntae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • Vertical drain has usually been used to accelerate the consolidation of soft clay deposits with high moisture content. Busan thick clay deposits are subjected to artesian pressure from an aquifer in sand and gravel layers. However, effect of artesian pressure existing in drainage-installed soft ground on consolidation behaviors is not well known. This paper investigates the consolidation behavior of drainage-installed soft ground at the Nakdong river estuary with artesian pressure and without artesian pressure. A series of one-dimensional large size column test was carried out to find out the consolidation characteristics of clay. Test results indicated that total settlement of clay with artesian pressure was higher than that without artesian pressure because effective stress decreased due to upward flow. Dissipation rate of excess pore water pressure delayed and excess pore water pressure did not fully dissipate in clay layer with artesian pressure. Undrained shear strength of clay ground with artesian pressure was lower than that without artesian pressure.

A Consideration on Deformation Characteristics of Normally-Consolidated Clays by Various Stress Paths (다양한 응력경로에 따른 정규압밀 점성토의 변형특성 고찰)

  • 김창엽;정충기
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.161-173
    • /
    • 1999
  • Settlement analysis based on oedometer test results with or without Skempton-Bjerrum's modification method ( widely used for practical purposes when estimating consolidation settlements of soft clay deposits) has shortcomings that it cannot simulate real stress states and deformation behaviors of soils in case that in-situ loading and deformation conditions are not 1-dimensional. In this study, the stress path method, reflecting various probable stress paths, was employed to normally - consolidated kaolinite samples by using automated triaxial testing device which can control stress paths automatically. From this experimental study, elastic, consolidation, secondary compression and pore pressure development - dissipation behaviors under various stress paths were analyzed and deformation characteristics of soft clays, which can be the basis of rational estimation of settlements, were studied. Also by comparing results of stress path tests with those of 1-dimensional consolidation tests, limitations and problems of conventional methods were clarified.

  • PDF

COSMIC RAY SPECTRUM IN SUPERNOVA REMNANT SHOCKS

  • Kang, Hye-Sung
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.25-39
    • /
    • 2010
  • We perform kinetic simulations of diffusive shock acceleration (DSA) in Type Ia supernova remnants (SNRs) expanding into a uniform interstellar medium (ISM). Bohm-like diffusion due to self-excited $Alfv\acute{e}n$ waves is assumed, and simple models for $Alfv\acute{e}nic$ drift and dissipation are adopted. Phenomenological models for thermal leakage injection are considered as well. We find that the preshock gas temperature is the primary parameter that governs the cosmic ray (CR) acceleration efficiency and energy spectrum, while the CR injection rate is a secondary parameter. For SNRs in the warm ISM of $T_0\lesssim10^5K$, if the injection fraction is $\xi\gtrsim10^{-4}K$, the DSA is efficient enough to convert more than 20% of the SN explosion energy into CRs and the accelerated CR spectrum exhibits a concave curvature flattening to $E^{-1.6}$, which is characteristic of CR modified shocks. Such a flat source spectrum near the knee energy, however, may not be reconciled with the CR spectrum observed at Earth. On the other hand, SNRs in the hot ISM of$T_{0}\approx10^{6}K$ with a small injection fraction, $\xi$<$10^{-4}$, are inefficient accelerators with less than 10% of the explosion energy getting converted to CRs. Also the shock structure is almost test-particle like and the ensuing CR spectrum can be steeper than $E^{-2}$. With amplified magnetic field strength of order of $30{\mu}G$ $Alfv\acute{e}n$ waves generated by the streaming instability may drift upstream fast enough to make the modified test-particle power-law as steep as $E^{-2.3}$, which is more consistent with the observed CR spectrum.

Multi-Scale Heterogeneous Fracture Modeling of Asphalt Mixture Using Microfabric Distinct Element Approach

  • Kim Hyun-Wook;Buttler William G.
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.139-152
    • /
    • 2006
  • Many experimental and numerical approaches have been developed to evaluate paving materials and to predict pavement response and distress. Micromechanical simulation modeling is a technology that can reduce the number of physical tests required in material formulation and design and that can provide more details, e.g., the internal stress and strain state, and energy evolution and dissipation in simulated specimens with realistic microstructural features. A clustered distinct element modeling (DEM) approach was implemented In the two-dimensional particle flow software package (PFC-2D) to study the complex behavior observed in asphalt mixture fracturing. The relationship between continuous and discontinuous material properties was defined based on the potential energy approach. The theoretical relationship was validated with the uniform axial compression and cantilever beam model using two-dimensional plane strain and plane stress models. A bilinear cohesive displacement-softening model was implemented as an intrinsic interface and applied for both homogeneous and heterogeneous fracture modeling in order to simulate behavior in the fracture process zone and to simulate crack propagation. A disk-shaped compact tension test (DC(T)) with heterogeneous microstructure was simulated and compared with the experimental fracture test results to study Mode I fracture. The realistic arbitrary crack propagation including crack deflection, microcracking, crack face sliding, crack branching, and crack tip blunting could be represented in the fracture models. This micromechanical modeling approach represents the early developmental stages towards a 'virtual asphalt laboratory,' where simulations of laboratory tests and eventually field response and distress predictions can be made to enhance our understanding of pavement distress mechanisms, such its thermal fracture, reflective cracking, and fatigue crack growth.

  • PDF

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.