• 제목/요약/키워드: dissipation test

검색결과 752건 처리시간 0.027초

드롭 착지와 착지 후 점프 시 충격흡수 기전의 차이 분석 (Analysis of the Differences of the Shock Absorption Strategy between Drop-Landing and Countermovement-Jump)

  • 조준행;김경훈;고영철
    • 한국운동역학회지
    • /
    • 제22권4호
    • /
    • pp.379-386
    • /
    • 2012
  • The aim of this study was to investigate and identify the differences in lower extremity energy dissipation strategies between drop-landing and countermovement-jump maneuvers. Fourteen recreational athletes(Age : $23.3{\pm}2.1years$, Height : $172.3{\pm}4.0cm$, Weight : $69.2{\pm}4.7kg$) were recruited and instructed to perform drop-landing from 45 cm height and countermovement-jump from 45 cm to 20 cm height. The landing phase was taken as the time between initial contact and peak knee flexion. A motion-capture system consisting of eight infra-red cameras was employed to collect kinematics data at a sampling rate of 200 Hz and a force-plate was used to collect GRF data at a sampling rate of 2000 Hz. Paired t-test was performed to determine the difference in kinematics and kinetics variables between each task. During the countermovement-jump task, all of lower extremity joint ROM and the hip joint eccentric moment were decreased and the ankle joint plantarflexion moment was increased than drop-landing task. In the eccentric work during countermovement-jump task, the ankle joint displayed greater while knee and hip joint showed lesser than drop-landing. Therefore, the knee joint acted as the key energy dissipater during drop-landing while the ankle joint contributed the most energy dissipation during countermovement-jump. Our findings collectively indicated that different energy dissipation strategies were adopted for drop-landing and countermovement-jump.

Seismic behavior of reinforced concrete T-shaped columns under compression-bending-shear and torsion

  • Ping, Chen Zong;Weiwei, Su;Yang, Yang
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.431-444
    • /
    • 2021
  • T-shaped column is usually used as side column in buildings, which is one of the weak members in structural system. This paper presented a quasi-static cyclic loading experiment of six specimens of reinforced concrete (RC) T-shaped columns under compression-flexure-shear-torsion combined loadings to investigate the effect in the ratio of torsion to moment (T/M) and axial compression ratio (n) and height-thickness ratio of flange plate (φ) on their seismic performance. Based on the test results, the failure characteristics, hysteretic curves, ductility, energy dissipation, stiffness degradation and strength degradation were analyzed. The results show that the failure characteristics of RC T-shaped columns mainly depend on the ratio of torsion to moment, which can be divided into bending failure, bending-torsion failure and shear-torsion failure. With the increase of T/M ratio, the torsion ductility coefficient increased, and in a suitable range, the torsion and horizontal displacement ductility coefficient of RC T-shaped columns could be effectively improved with the increase of axial compression ratio and the decrease of height-thickness ratio of flange plate. Besides, the energy dissipation capacity of the specimens mainly depended on the bending and shear energy dissipation capacity. On the other hand, the increase of axial compression ratio and the ratio of torsion to moment could accelerate the torsional and bending stiffness degradation of RC T-shaped columns. Moreover, the degradation coefficient of torsion strength was between 0.80 and 0.98, and that of bending strength was between 0.75 and 1.00.

생산단계에서 소비단계 생식 쑥갓의 azoxystrobin 잔류량에 따른 위해성 평가 (Risk Assessment of Azoxystrobin Residues in Fresh Crown Daisy from Farm to Fork)

  • 반선우;오아연;장희라
    • 한국환경농학회지
    • /
    • 제42권2호
    • /
    • pp.131-138
    • /
    • 2023
  • The biological half-life and dissipation rate of azoxystrobin in crown daisy were calculated to establish the pre-harvest residue limits (PHRLs). The pesticide residues were calculated after washing with five different processes to propose an effective process in the household and conducted a risk assessment to confirm dietary safety. Azoxystrobin was sprayed according to the critical good agricultural practices (cGAP) in two different field trials, and the samples were harvested 7 times. The limit of quantitation was 0.02 mg/kg, and the mean recoveries of azoxystrobin were within the range of 70~120% with below 20% coefficient variation at the concentration of 0.02 and 0.2 mg/kg . The biological half-lives were 7.4 and 4.7 days, and the dissipation rate constants were 0.0872 and 0.1217 in fields 1 and 2, respectively. The average removal rates were 58.13~78.13% by the different washing processes, and there were significant differences between the washing processes (one-way ANOVA analysis and post-hoc Duncan test, p-value<0.05). The residues of azoxystrobin in crown daisy were safe levels from farm to fork after application with the critical good agricultural practice (cGAP) registered in Korea.

부착 긴장재를 가진 조립식 교각 설계변수의 구조성능에 미치는 영향 (Effects of Design Parameters on Structural Performance of Precast Piers with Bonded Prestressing Steels)

  • 심창수;윤재영
    • 대한토목학회논문집
    • /
    • 제30권1A호
    • /
    • pp.15-26
    • /
    • 2010
  • 부착 긴장재를 이용한 프리스트레스를 도입하는 조립식 교각의 구조 성능을 평가하기 위한 준정적 실험을 수행하였다. 프리캐스트 교각의 이음부를 가로질러 축방향으로 연속배치되는 강재로 강봉과 일반철근, 매입강관과 강연선의 조합을 선택하였다. 주요 설계 변수는 강재량, 프리스트레스의 수준, 단면 상세로 하였다. 이음부 벌어짐 이후에 연속 강재가 하중을 모두 부담하여 응력의 증감을 일으키는데 강재비가 높을수록 휨강도가 높게 나타나고 에너지 소산능력도 현저하게 증가하였다. 매입강재를 갖는 프리캐스트 교각은 최대하중 이후의 거동이 안정적으로 나타나 높은 변위연성도를 나타내었고 프리스트레스 증가에 따른 에너지 소산능력의 증가도 나타내었다. 프리스트레스의 수준이 높을수록 초기 변형 회복능력이 양호하게 나타났고 횡철근의 응력증가도 크게 나타났다. 조립식 교각의 최대하중 도달 이후의 강도 저하가 급격하게 발생하지 않도록 긴장재와 일반강재의 조합을 결정하여야 한다.

인버터 구동형 저압 유동전동기의 절연특성 분석 (Analysis of Insulation Characteristics of Low-Voltage Induction Motors Fed by Pulse-Controlled Inverters)

  • 박도영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2000
  • In this paper the insulation characteristics test results of 25 low-voltage induction motors($3\phi$, 5HP, 380V) are presented. Five different types of insulation techniques are applied to 25 motors. The maximum partial discharge (PD) magnitude ($\textrm{Q}_{m}$) discharge inception voltage (DIV) dissipation factor tip-up ($\Delta$tan$\delta$) and rate of change in AC current($\Delta$I) are measured by PD and AC current tests. Also the insulation breakdown tests by high voltage pulse are performed and the corresponding breakdown voltage are obtained.

  • PDF

상재하중에 의한 연약점토의 일차원 압밀에 관한 원심모형실험 (Centrifuge Model Experiments on One-dimensional Consolidation of Soft Clay with Surcharges)

  • 유남재;이명욱;이종호
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.103-110
    • /
    • 1997
  • This thesis is to investigate the one-dimensional consolidation behavior of soft marine clay with uniform surcharges by perfoming numerical and experimental works. Parametric experimental works of centrifuge model test were carried out changing test conditions of gravitational level in centrifuge, magnitude of surcharges and construction sequence of applying surcharges. Results of centrifuge model experiments were analyzed by using the numerical technique of explicit finite difference method based on the finite strain consolidation theory, being known to be appropriate to analyze the consolidational behavior of soft clay with a very high initial void ratio using the Lagrangian and the material coordinate systems. Test results were in relatively good agreements with analyzed results in terms of excess pore pressure dissipation and consolidation settlement with time and final void ratio distribution.

  • PDF

동적혼성 모델을 이용한 난류채널의 온도장 해석 (On the Large Eddy Simulation of Temperature Field Using Dynamic Mixed Model in a Turbulent Channel)

  • 이건호;나양
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1255-1263
    • /
    • 2004
  • An a priori test has been conducted for the dynamic mixed model which was generalized for the prediction of passive scalar field in a turbulent channel flow The results from a priori tests indicated that dynamic mixed model is capable of predicting both subgrid-scale heat flux and dissipation rather accurately. The success is attributed to the explicitly calculated resolved term incorporated into the model. The actual test of the model in a LES a posteriori showed that dynamic mixed model is superior to the widely used dynamic Smagorinsky model in the prediction of temperature statistics.

반복하중을 받는 철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 구조성능 평가 및 개선 (Improvement and Evaluation of Structural performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame under Load Reversals)

  • 신종학;하기주;김광연;이희종;남왕교
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.541-546
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation of and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-l~3), cumulated energy dissipation capacities wear increased by 1.35~l.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.

  • PDF

철근콘크리트 프레임면내 조적벽체의 내진성능개선 기술 개발 (Development of Technique for Improvement of Earthquake-Resistant Performance of Reinforced Concrete Infilled Masonry Frame)

  • 신종학;하기주;최민권;권중배;남왕교
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1143-1148
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as hysteretic behavior, maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infiiled wall were constructed and tested in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled walls with restraining factors of frame, maximum horizontal capacities were increased by 1.26~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-1), cumulated energy dissipation capacities wear increased by 1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.

  • PDF

On the Large Eddy Simulation of Scalar Transport with Prandtl Number up to 10 Using Dynamic Mixed Model

  • Na Yang
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.913-923
    • /
    • 2005
  • The dynamic mixed model (DMM) combined with a box filter of Zang et. al. (1993) has been generalized for passive scalar transport and applied to large eddy simulation of turbulent channel flows with Prandtl number up to 10. Results from a priori test showed that DMM is capable of predicting both subgrid-scale (SGS) scalar flux and dissipation rather accurately for the Prandtl numbers considered. This would suggest that the favorable feature of DMM, originally developed for the velocity field, works equally well for scalar transport problem. The validity of the DMM has also been tested a posteriori. The results of the large eddy simulation showed that DMM is superior to the dynamic Smagorinsky model in the prediction of scalar field and the model performance of DMM depends to a lesser degree on the ratio of test to grid filter widths, unlike in the a priori test.