• 제목/요약/키워드: display controller

검색결과 335건 처리시간 0.027초

Construction and Operation of High-$T_c$ Scanning SQUID Microscope

  • Baeka, B.;Kim, Ho-chul;Khim, Z.G.;Lee, S.M.;Moon, S.H.;Oh, B.
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.20-25
    • /
    • 1999
  • We constructed a high-$T_c$ scanning SQUID microscope (SSM) operating in the liquid nitrogen. We used a washer-type YBCO SQUID with inner and outer dimensions of $12{\mu}m$ and $36{\mu}m$, respectively, which was grown on the $SrTiO^3$ bicrystal substrate. The sample, rather than SQUID, was scanned using two stepping motors. We also developed readout electronics, stepping motor controller, and the software for system control and data display. We took images of various samples using our SSM and found that the spatial resolution is about $40{\mu}m$ and noise level is lower than $10^{-7}T/{\surd}Hz$ at 100 Hz and higher at lower frequencies. The noise level was much higher than that of a typical SQUID due to the other coupling from the electric parts. We present a simple argument on the inductive coupling between the sample and the SQUID which should be under-stood for the proper interpretation of the obtained images. By comparing the measured data with the simulation results the gap between the SQUID and the sample is estimated to be $40{\mu}m$.

  • PDF

Engineered Tunnel Barrier Ploy-TFT Memory for System on Panel

  • 유희욱;이영희;정홍배;조원주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.128-128
    • /
    • 2011
  • Polysilicon thin-film transistors (poly-Si TFTs)는 능동행렬 액정 표시 소자(AMLCD : Active Matrix Liquid Crystal Display)와 DRAM과 같은 메모리 분야에 폭넓게 적용이 가능하기 때문에 많은 연구가 진행되고 있다. 최근 poly-Si TFTs의 우수한 특성으로 인하여 주변 driving circuits에 직접화가 가능하게 되었다. 또한 디스플레이 LCD 패널에 controller와 메모리와 같은 다 기능의 장치을 직접화 하여 비용의 절감과 소자의 소형화가 가능한 SOP (System on panels)에 연구 또한 진행 되고 있다. 이미 잘 알려진 바와 같이 비휘발성 메모리는 낮은 소비전력과 비휘발성이라는 특성 때문에 이동식 디바이스에 데이터 저장 장치로 많이 사용되고 있다. 하지만 플로팅 타입의 비휘발성 메모리는 제작공정의 문제로 인하여 SOP의 적용에 어려움을 가지고 있다. SONOS 타입의 메모리는 빠른 쓰기/지우기 효율과 긴 데이터 유지 특성을 가지고 있으나 소자의 스케일링 따른 누설전류의 증가와 10년의 데이터 보존 특성을 만족 시킬 수 가 없는 문제가 발생한다. 본 연구에서는 SOP 적용을 위하여 ELA 방법을 통하여 결정화한 poly-Si TFT memory를 SiO2/Si3N4/SiO2 Tunnel barrier와 High-k HfO2과 Al2O3을 Trapping layer와 Blocking layer로 적용, 비휘발성 메모리을 제작하여 전기적 특성을 알아보았다.

  • PDF

금속 부품의 결함 판단을 위한 고유 주파수 분석 시스템 개발 (Development of the Natural Frequency Analysis System to Examine the Defects of Metal Parts)

  • 이충석;김진영;강준희
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.169-174
    • /
    • 2015
  • In this study, we developed a system to detect the various defects in the metallic objects using the phenomenon that the defects cause the changes of the natural resonant frequencies. Our system consists of a FFT Amp, an Auto Impact Hammer, a Hammer controller and a PC. Auto Impact Hammer creates vibrations in the metallic objects when tapped on the surface. These vibrational signals are converted to the voltage signals by an acceleration sensor attached to the metallic part surface. These analog voltage signals were fed into an ADC (analog-digital converter) and an FFT (fast fourier transform) conversion in the FFT Amp to obtain the digital data in the frequency domain. Labview graphical program was used to process the digital data from th FFT amp to display the spectrum. We compared those spectra with the standard spectrum to find the shifts in the resonant frequencies of the metal parts, and thus detecting the defects. We used PCB's acceleration sensor and TI's TMS320F28335 DSP (digital signal processor) to obtain the resolution of 2.93 Hz and to analyze the frequencies up to 44 kHz.

MgO 증착을 위한 유도결합 플라즈마 마그네트론 스퍼터링에서 실시간 공정 진단 (A Real-Time Diagnostic Study of MgO Thin Film Deposition Process by ICP Magnetron Sputtering Method)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제38권2호
    • /
    • pp.73-78
    • /
    • 2005
  • A real-time monitoring of ICP(inductively coupled plasma) assisted magnetron sputtering of MgO was carried out using a QMS(quadrupole mass spectrometer), an OES(optical emission spectrometer), and a digital oscilloscope with a high voltage probe and a current monitor. At the time of ICP ignition, the most distinct impurity was OH emission (308.9 nm) which was dissociated from water molecules. For reactive deposition oxygen was added to Ar and the OH emission intensity was reduced abruptly When the discharge voltage was regulated by a PID controller from 240V(metallic mode) to 120V(oxide mode), the emission intensity from Mg (285.2 nm) changed proportionally to the discharge voltage, but the intensity of Ar I(811.6 nm) was constant. At 100V of discharge voltage, Mg sputtering was almost stopped. Emissions from Ar I(420.1 nm) and Mg I were dropped down to 1/10, but Ar I(811.6 nm) didn't change. And the emission from atomic oxygen (O I, 777.3 nm) was increased to 10 times. These results are compatible with those from QMS study.

배전원격관리를 위한 차세대 디지털 적산전력계 개발 (Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems)

  • 고윤석;윤상문;서성진;강태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

환자모니터링시스템의 개발 : 전체구조 및 기본사양 (Development of a Patient Monitoring System Overall Architecture and Specifications)

  • 우응제;박승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

Prototype Milli Gauss Meter Using Giant Magnetoimpedance Effect in Self Biased Amorphous Ribbon

  • Kollu, Pratap;Yoon, Seok-Soo;Kim, Gun-Woo;Angani, C.S.;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.194-198
    • /
    • 2010
  • In our present work, we developed a GMI (giant magnetoimpedance) sensor system to detect magnetic fields in the milli gauss range based on the asymmetric magnetoimpedance (AGMI) effect in Co-based amorphous ribbon with self bias field produced by field-annealing in open air. The system comprises magnetoimpedance sensor probe, signal conditioning circuits, A/D converter, USB controller, notebook computer, and program for measurement and display. Sensor probe was constructed by wire-bonding the cobalt based amorphous ribbon with dimensions $10\;mm\;{\times}\;1\;mm\;{\times}\;20\;{\mu}m$ on a printed circuit board. Negative feedback was used to remove the hysteresis and temperature dependence and to increase the linearity of the system. Sensitivity of the milli gauss meter was 0.3 V/Oe and the magnetic field resolution and environmental noise level were less than 0.01 Oe and 2 mOe, respectively, in an unshielded room.

MCU에 내장된 플레쉬 메모리 오동작 테스트 가능한 ROM Writer 개발 (Development of a ROM Writer for Shmoo Test of a Flash Memory Integrated into the MCU)

  • 김태선;박차훈
    • 한국산업정보학회논문지
    • /
    • 제20권4호
    • /
    • pp.103-109
    • /
    • 2015
  • 본 논문은 MCU에 내장된 플레쉬 메모리의 오동작 테스트를 shmoo 테스트 기법을 사용하고, 이 기능을 내장한 롬라이트 개발에 관한 논문이다. shmoo 테스트는 다양한 입력조건에 대한 응답을 도표로 나타내고 분석하는 기법으로, 마이크로프로세서, ASIC 및 메모리와 같은 집적회로 또는 컴퓨터 시스템의 성능분석의 기법으로 사용된다. 개발된 롬라이터는 Shmoo 검사를 수행하고 Flash 32K의 쓰기를 수행하였을 때 6.4s 정도의 시간이 소요되었으며, 이는 현재 사용하고 있는 ROM Writer의 속도에 비해 약 20% 정도 향상되었다.

몰입 로봇 수술을 위한 새로운 단일렌즈 3D 내시경과 시점 조절 시스템 (A Novel Single Lens 3D Endoscope and Endoscopic View Controller for Immersive Robotic Surgery System)

  • 유성근;박상일;윤소정;엄유미
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2015년도 하계학술대회
    • /
    • pp.524-526
    • /
    • 2015
  • 본 논문은 자유 시점조절과 깊이감 조절이 가능한 단일렌즈 양안시 3D 내시경과 Head-mounted display 를 사용한 새로운 로봇수술 시스템을 제안한다. 최근 들어서 여러 양안식 입체영상장치가 의료 영역에 적용되고 있다. 그러나 3D 의료 장비들은 zooming 과 자유로운 시점조절, 그리고 접사를 하는 데에 한계가 존재한다. 입체영상 장비에서 필연적으로 발생하는 이러한 문제점들은 3D 영화를 찍기 위해서 사용되는 것과 같은 2 대의 카메라와 2 개의 렌즈를 사용하는 데에서 원인을 찾을 수 있다. 이러한 문제점들은 Da Vinci 로봇 수술 시스템과 같은 가장 최신의 시스템에서도 해결되지 못하였다. 본 논문에서 제안하는 새로운 시스템은 지금까지 제시된 문제점들을 해결하고, 현재 존재하는 로봇 수술 시스템에 몰입 입체영상 수술이나 증강 현실 수술을 가능하게 하기 위한 목적으로 제안되었다.

  • PDF

LCD 구동 시스템에서 전력 소비 및 전자기 장애를 줄이기 위한 데이타 코딩 방법 (Data Coding Scheme to Reduce Power Consumption and EMI in LCD Driving Systems)

  • 최철호;최명렬
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제6권6호
    • /
    • pp.628-634
    • /
    • 2000
  • 본 논문에서는 LCD(Liquid Crystal Display) 컨트롤러와 LCD 구동 칩 사이의 신호 전송에서 전력 소비 및 전자기 장애(EMI)를 줄이기 위한 데이타 코딩 방법을 제안하였다. 제안한 방식은 컴퓨터의 일반적인 텍스트 화면에 대한 데이타 천이(transition)를 감소시키는 방식으로 하드웨어 구조가 간단하여 실시간 처리가 요구되는 LCD 구동 시스템에 적용하기 용이하다. 제안한 방식의 성능 분석을 위해 컴퓨터를 이용한 시뮬레이션을 수행하였으며 기존의 코딩 방식과의 성능 비교 및 평가를 하였다. 시뮬레이션을 통해 제안한 방식이 기존 방식에 비하여 텍스트 화면과 그림 화면에 대해서 switching activity를 현저히 줄일 수 있음을 확인하였다.

  • PDF