• Title/Summary/Keyword: dispersion method

Search Result 1,631, Processing Time 0.033 seconds

The Fabrication of Gas Sensors using MWCNTs (다중벽 카본 나노 튜브를 이용한 가스센서의 제작)

  • Jang, Kyung-Uk;Kim, Myung-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1089-1094
    • /
    • 2009
  • Carbon nanotubes (CNTs) have excellent electrical, chemical stability, mechanical and thermal properties. In this paper, networks of Multi-walled carbon nanotube (MWCNT) materials were investigated as resistive gas sensors for ethanol ($C_2H_5OH$) detection. Sensor films were fabricated by air spray method for the multi-walled CNTs solution on glass substrates. Sensors were characterized by resistance measurements in the sensing system, in order to find the optimum detection properties for the ethanol gas molecular. The film that was sprayed with the MWCNT dispersion for 60 see, was 300 nm thick. And the electric resistivity is $2{\times}10^{-2}\;{\Omega\cdot}cm$. Also, the sensitivity and the linearity of MWVNT sensor for ethanol gas are 0.389 %/sec and 17.541 %/FS, respectively. The MWCNT film was excellent in the response for the ethanol gas molecules and its reaction speed was very fast, which could be using as ethanol gas sensor. The conductance of the fabricated sensors decreases when the sensors are exposed to ethanol gas.

A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network (웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구)

  • Park, Jae-Jun;Jeon, Hyun-Gu;Jeon, Byung-Hoon;Kim, Sung-Hong;Kwon, Dong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

Thermal Property of CNT/Cu Nanocomposite (Carbon Nanotube/Cu 나노복합체의 열적특성)

  • Hong, Youn-Jeong;Kim, Hye-Jin;Jung, Chung-Hun;Lee, Kyu-Mann
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.89-90
    • /
    • 2006
  • The CNTs are of great interest because of their unique complete properties of matter, especially, the large thermal conductivity (Thermal conductivity of CNTs ~ >2000W /mK vs. Thermal conductivity of Aluminum ~ >204W/mK). However, owing to the strong agglomeration cause by the vander wall's force, the CNTs are limited to applicate. In this study. we suggest a new method for CNTs dispersion. which are developed by the mechanical and chemical method. and then Cu was coated. This new process produces CNTs/Cu nanocomposite powders. The CNTs are homogeneously located within the Cu powders by chemical reaction. And the thermal properties of the CNTs/Cu nanocomposite were investigated.

  • PDF

Adaptive Searching Estimation in Stratified Spatial Sample design (적합탐색 관찰을 이용한 층화 공간표본설계에서의 추정)

  • 변종석
    • The Korean Journal of Applied Statistics
    • /
    • v.13 no.2
    • /
    • pp.353-369
    • /
    • 2000
  • We systematized an stratified spatial sample design(SSSD) that uses the adequate stratification criteria such as the shapeness or the dispersion of an interesting region in a spatial population. And we proposed an adaptive searching estimation method in the SSSD to estimate the area of region of interest in two-dimensional surfaces. When wc adopt the proposed adaptive searching estimation method in SSSD, the observing sample size is more decreased than a classical sample design that all the designed sample size is observed. Nevertheless it has been shown that we can produce the moderate result but the efficiency is a slight reduced.

  • PDF

Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD) (HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kwon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

Analysis of Nonclassical Fullerene C24 Regioisomers Encapsulating H2O using Hybrid Density Functional Methods B3LYP and M06-2X

  • Lee, Seol;Lee, Ji Young;Lee, Kee Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.899-904
    • /
    • 2014
  • The atomic structures and electronic properties of six classical and nonclassical $H_2O$@$C_{24}$ fullerene regioisomers are systematically studied using the hybrid density functional B3LYP method and M06-2X method with empirical dispersion in conjunction with the 6-31G(d,p) basis sets. The charge transfer, frontier orbitals, dipole moment, energy gap between the HOMO and LUMO, and volume change of the $C_{24}$ cage are analyzed upon encapsulation of a $H_2O$ molecule in each $C_{24}$ regioisomer. All encapsulation processes are endothermic and the relative stabilities of six $C_{24}$ fullerene regioisomers change upon encapsulation of $H_2O$.

Analysis of the optimum optical signal power and the longest transmission length in nonlinear optical transmission systems (비선형 광통신 시스템에서 최대 전송거리 및 최적 광신호 세기 도출에 관한 연구)

  • Kim, Sung-Man
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.567-571
    • /
    • 2012
  • To design the long-haul optical communication system, we need to decide the type of optical fiber and optical amplifier, span length of optical amplifier, dispersion compensation method, optical signal power, etc. Therefore, we need to predict the performance of optical communication system when we change one of the system parameters. In this paper, we investigate the method of predicting the maximum transmission length of the designed optical communication system and finding the optimum optical signal power to obtain the maximum transmission length.

Uncertainty Evaluation of the Estimated Release Rate for the Atmospheric Pollutant Using Monte Carlo Method (Monte Carlo 방법을 이용한 대기오염 배출률 예측의 불확실성 평가)

  • Jeong, Hyo-Joon;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Han, Moon-Hee
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.319-324
    • /
    • 2006
  • Release rate is one of the important items for the environmental impact assessment caused by radioactive materials in case of an accidental release from the nuclear facilities. In this study, the uncertainty of the estimated release rate is evaluated using Monte Carlo method. Gaussian plume model and linear programming are used for estimating the release rate of a source material. Tracer experiment is performed at the Yeoung-Kwang nuclear site to understand the dispersion characteristics. The optimized release rate was 1.56 times rather than the released source as a result of the linear programming to minimize the sum of square errors between the observed concentrations of the experiment and the calculated ones using Gaussian plume model. In the mean time, 95% confidence interval of the estimated release rate was from 1.41 to 2.53 times compared with the released rate as a result of the Monte Carlo simulation considering input variations of the Gaussian plume model. We confirm that this kind of the uncertainty evaluation for the source rate can support decision making appropriately in case of the radiological emergencies.

Development of Petroleum-Based Carbon Composite Materials Containing Graphite/silicon Particles and Their Application to Lithium Ion Battery Anodes

  • Noh, Soon-Young;Kim, Young-Hoon;Lee, Chul-Wee;Yoon, Song-Hun
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.116-123
    • /
    • 2011
  • Herein, a novel preparation method of highly homogeneous carbon-silicon composite materials was presented. In contrast to conventional solvent evaporation method, a milled silicon-graphite or its oxidized material were directly reacted with petroleum-derived pitch precursor. After thermal reaction under high pressure, pitch-graphite-silicon composite was prepared. Carbon-graphite-silicon composite were prepared by an air-oxidization and following carbonization. From energy dispersive spectroscopy, it was observed that small Si particles were highly embedded within carbon, which was confirmed by disappearance of Si peaks in Raman spectra. Furthermore, X-ray diffraction and Raman spectra revealed that carbon crystallinity decreased when the strongly oxidized silicon-graphite was added, which was probably due to oxygen-induced cross-linking. From the anode application in lithium ion batteries, carbon-graphite-silicon composite anode displayed a high capacity ($565\;mAh\;g^{-1}$), a good initial efficiency (68%) and an good cyclability (88% retention at 50 cycles), which were attributed to the high dispersion of Si particles within cabon. In case of the strongly oxidized silicongraphite addtion, a decrease of reversible capacity was observed due to its low crystallinity.

Calibration of a Korean Weapon Systems Wargame Model (한국적 무기체계의 워게임 모델 교정에 관한 연구)

  • Jung, Kun-Ho;Yum, Bong-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Some of the wargame simulators currently used in the Korean Army were developed by other countries, and do not adequately reflect the Korean Peninsula terrain and weapon systems. This implies that these war game simulators need to be calibrated with respect to the input parameters for properly assessing the effectiveness of the Korean weapon systems. In this paper, AWAM, a wargame simulator, is calibrated in terms of the time-based fighting power(FP). The FP data obtained from the Korea Combat Training Center(KCTC) are used as a reference, and the differences between the AWAM and KCTC FP data are calculated at certain points in time. Then, the Taguchi robust design method is adopted using the probabilities of hitting for the K-2 rifle as controllable input parameters. Two performance characteristics are used. One is the difference between the AWAM and KCTC FP data and the other is the score derived by grouping the difference data. For each case, optimal settings of the probabilities of hitting are determined such that the mean of each characteristic is close to 0 with its dispersion being as small as possible.