• Title/Summary/Keyword: discrepancy

Search Result 1,899, Processing Time 0.028 seconds

Enhanced-Precision LHSMC of Electrical Circuit Considering Low Discrepancy

  • Park, Eun-Suk;Oh, Deok-Keun;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.101-113
    • /
    • 2015
  • The Monte-Carlo (MC) technique is very efficient solution for statistical problem. Various MC methods can easily be applied to statistical circuit performance analysis. Recently, as the number of process parameters and their impact, has increasingly affected circuit performance, a sufficient sample size is required in order to consider high dimensionality, profound nonlinearity, and stringent accuracy requirements. Also, it is important to identify the performance of circuit as soon as possible. In this paper, Fast MC method is proposed for efficient analysis of circuit performance. The proposed method analyzes performance using enhanced-precision Latin Hypercube Sampling Monte Carlo (LHSMC). To increase the accuracy of the analysis, we calculate the effective dimension for the low discrepancy value on critical parameters. This will guarantee a robust input vector for the critical parameters. Using a 90nm process parameter and OP-AMP, we verified the accuracy and reliability of the proposed method in comparison with the standard MC, LHS and Quasi Monte Carlo (QMC).

Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study

  • Woo, Hyun-Wook;Cho, Sung-Am;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.128-131
    • /
    • 2018
  • PURPOSE. This study aimed to evaluate the marginal discrepancy of full-arch frameworks in implant-supported prostheses fabricated using pre-sintered soft alloy (PSA). MATERIALS AND METHODS. Full-arch metal frameworks were fabricated on the edentulous implant model using casting alloy (CA), fully-sintered hard alloy (FHA), and PSA (n = 4 in each group). To evaluate the misfit of the framework to the abutments, the absolute marginal discrepancy (AMD) values of the frameworks were measured in cross-sectional images that had been drawn as part of the triple-scan protocol. The AMD values were compared among the tested alloy groups using the Kruskal-Wallis test, with a post hoc Mann-Whitney U test (${\alpha}=.05$). RESULTS. The FHA and PSA groups showed lower marginal discrepancies than the CA group (P<.001). However, the FHA group did not differ significantly from the PSA group. CONCLUSION. Soft alloy milling is comparable to hard alloy milling, and it is more precise than casting in terms of the marginal fit of implant-supported, full-arch prostheses.

The Effects of Internal-External Locus of Control on Level of Aspiration in Korean Children (아동(兒童)의 내(內)·외통제신념(外統制信念)이 포부수준(抱負水準)에 미치는 영향(影響))

  • Joen, Kyoung Mie
    • Korean Journal of Child Studies
    • /
    • v.4
    • /
    • pp.53-61
    • /
    • 1983
  • The purpose of this study was to investigate the effects of internal-external locus of control on level of aspiration in Korean Children. The locus of control was measured by means of the Nowicki & Strickland's "A Locus of Control Scale for Children (1973)". The level of aspiration was measured by "Throw Balls into the Basket Game" Sixty internal controlled children(30 girls and 30 boys) and 60 external controlled children(30 girls and 30 boys) were selected among 853 children in fifth grade. For the data analysis, two - way analysis of variance and t-test were applied, Pearson correlation coefficient was computed. The results of this study were as follows; 1. Goal discrepancy score were significantly higher in the internal controlled children than in the external controlled children. 2. Shift value were significantly higher in the external controlled children than in the internal controlled children. 3. School achievement were significantly higher in the internal controlled children than in the external controlled children. 4. There was no significant difference in the school achievement between the children who showed high goal discrepancy score and the children who showed low one. 5. There was no significant difference in the locus of control between girls and boys. 6. Goal discrepancy score were significantly higher in boys than in girls, but there was no significant difference in the shift value between girls and boys.

  • PDF

A Case Study on Complying Requirements of the Description of the Goods in Documentary Credit Transactions (화환신용장거래에서 물품명세의 일치성요건에 관한 사례연구)

  • Kim, Jong-Chill
    • International Commerce and Information Review
    • /
    • v.10 no.3
    • /
    • pp.239-261
    • /
    • 2008
  • Documentary credit transactions are judged by the principle of strict compliance. The compliance of the tendered documents with the credit's teams ensures the proper completion of the underlying transaction. But if the documents tendered by beneficiary differ, a discrepancy of documents occurs. Such a discrepancy raises difficult problems for the bank to which the documents are tendered. It has to decide whether to reject or accept them or to accept them under a protective mechanism. Therefore, this study is to examine the case study of complying presentation of the description of the goods in documentary credit through the Korean Supreme Court Cases. The objectives of this paper are as follow : 1. To examine two point of views on document compliance such as strict compliance and substantial compliance. 2. To analyze Korean Case Law which challenges the legal conclusions, standard for examination of documents and New ISBP. 3. To draw out the criterion for conformity and discrepancy of description in invoices and WC and to provide the guidelines for determining the nature and extent of an issuing bank's duty of documentary compliance. 4. Finally to suggest some implications through the Korean case law. By using the examination standards for description of goods suggested in Korean Case Law and New ISBP, the traders will be able to prepare documentation more perfectly and document checkers will be able to examine the negotiation documents more easily.

  • PDF

Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown (도재용 코발트-크롬 금속관의 변연적합도 비교)

  • Jeon, Byung-Wook;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

Marginal dicrepancy and topography of the artificial crown on the extracted abutment (발치된 치아에 부착된 수복물의 변연 적합 및 형태)

  • Lee, Jeong-Hoon;Choi, Min-Ho;Kim, Min-Ho;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.313-320
    • /
    • 2002
  • The purpose of the present study was to evaluate the marginal discrepancy and topography of artificial crown on teeth extracted due to severe periodontal disease. Twenty specimens were invested into metamethylacrylate resin and cutted into vertical slices along with the long axis of tooth. The selected marginal discrepancy between the outer edge of the crown and the finishing line of abutment was examined by stereo- microscope(Olympus, PM-VSP-3, Japan) at magnification of up to 10, and the topography of finishing margin on crown was observed by stereomicroscopeat magnification of up to $70{\times}$. The results were as follows. (1) The mean marginal discrepancy between extracted tooth and artificial crown were $50.82{\mu}m$. (2) There was a considerable difference in the microstructure of finishing margins among specimens. Microscopic Structure on finishing margin showed indefinite line, poor fit (open, underextended and overextended), distorted margin, and surface roughness. This study suggested that there could be necessary to consider the response of periodontium to the emergence profile of natural tooth and precision of marginal geometry while establishing treatment planning for the reconsruction of the artificial crown.

Boundary Layer Flow Under a Sluice Gate (수직수문하의 경계층흐름)

  • 이정열
    • Water for future
    • /
    • v.27 no.3
    • /
    • pp.95-105
    • /
    • 1994
  • The boundary layer flow under a sluice gate is numerically solved by the random vortex sheet method combined with the vortex-in-cell method in a boundary-fitted coordinate system. The numerical solution shows that the boundary layer developed along the vertical sluice gate wall is the primary cause for the discrepancy in the contraction ratio between the laboratory experiments and inviscid theory; the bottom boundary layer plays much a smaller role in the discrepancy. By dimensional analysis it is concluded that the discrepancy is inversely proportional to the 3/4th power of the gate opening, as analyzed by Benjamin(1956). The results of the numerical simulation and dimensional analysis show a good agreement with experimental results obtained by Benjamin(1956).

  • PDF

Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length (감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 -)

  • Kwon, Young-Ho;Kim, Jae-Do;Chung, So-Hak;Cho, Yool
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • In 1996, a nine-year-old girl was treated with recycling autograft after wide resection of the distal femoral osteosarcoma. The leg lengthening and revision with growing tumor prosthesis were performed due to limb leg discrepancy and epiphyseal problem. However, deep infection developed after operation, and a temporary spacer with cement and Ender nail was inserted. After infection was controlled completely, the final leg lengthening was performed with mono-external fixator for limb length discrepancy (10 cm). Lastly, Tumor prosthesis was reinserted to preserve the joint function.

  • PDF

Characteristics of Pelvic Ranges According to Artificial Leg Length Discrepancy During Gait: Three-Dimensional Analysis in Healthy Individuals (보행 중 인위적 다리길이 차이에 따른 3차원적 골반 가동범위의 특성)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Purpose : The purpose of this study was to analyze the dynamic range of motion (ROM) of pelvic and translation of center of mass (COM) when wearing different shoe insole lifts according to leg length discrepancy (LLD) during free speed gait. Methods : Thirty-five healthy adults were participated in this study. Kinematic data were collected using a Vicon motion capture system. Reflective and cluster 40 markers attached to participants lower extremities and were asked to walk in a 6 m gait way under three different shoe lift conditions (without any insole, 1 cm insole, and 2 cm insole). The pelvic ROM and COM translation in three planes were sorted using a Nexus software, and a Visual3D motion analysis software was used to coordinate all kinematic data. Results : There were significantly increased maximal pelvic elevation and total pelvic range in coronal plane when wearing a standard shoe with 2 cm insole lift during gait (p<.05). When wearing a standard shoe with 2 cm insole lift, the total range of the pelvic segment were significantly different in all three motion planes (p<.05). Conclusion : Although LLD of less than 2 cm develops abnormal movement pattern of the pelvis and may cause of musculoskeletal diseases such as low back pain, hip and knee joint osteoarthritis, therefore intensive various physical therapy interventions for LLD are needed.

Relationship between 3D Ground Reaction Force and Leg Length Discrepancy during Gait among Standing Workers

  • Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • Purpose: The aim of this research was to verify the relationship between three-dimensional (3D) ground reaction force (GRF) and severity of leg length discrepancy (LLD) while walking at a normal speed. It used a 3D motion analysis system with force platforms in standing workers with LLD. Methods: Subjects comprising 45 standing workers with LLD were selected. Two force platforms were used to acquire 3D GRF data based on a motion analysis system during gait. Vicon Nexus and Visual3D v6 Professional software were used to analyze kinetic GRF data. The subjects were asked to walk on a walkway with 40 infrared reflective markers attached to their lower extremities to collect 3D GRF data. Results: The results indicated the maximal force in the posterior and lateral direction of the long limb occurring in the early stance phase during gait had significant positive correlation with LLD severity (r = 0.664~0.738, p <0.01). In addition, the maximal force medial direction of the long limb occurring in the late stance phase showed a highly positive correlation with the LLD measurement (r = 0.527, p <0.01). Conclusion: Our results indicate that greater measured LLD severity results in more plantar pressure occurring in the foot area during heel contact to loading response of the stance phase and the stance push-off period during gait.