• Title/Summary/Keyword: discharge signal

Search Result 409, Processing Time 0.028 seconds

A Study of Partial Discharge RF Sensor for wide band with Cavity (캐버티를 갖는 광대역 부분방전 RF 센서 연구)

  • Rhee, Seung-Yeop;Cho, Ki-Ryang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.227-232
    • /
    • 2021
  • In this paper, the narrow-band characteristic, which is the disadvantage of the existing the PD sensor, was improved by transforming the sensor shape into a trapezoidal shape to improve the characteristics of the dipole-shaped conventional PD(Patial Discharge) sensor. In addition, by applying a cavity structure, which is a structure that can fundamentally block the electromagnetic wave signal from the outside as it is used for an external sensor, it is a partial discharge sensor that takes advantage of the structural advantages of low cost and convenience of installation. As a result of the experiment, it was shown that there is a broadband characteristic of about 70.5%(1.59~3.32GHz) at the center frequency of 2.45GHz, and the broadband characteristic was confirmed.

Large Signal Determination of Non-Linear Output Capacitance of Gallium-Nitride Field Effect Transistors from Switch-Off Voltage Transients - A Numerical Method

  • Pentz, David;Joannou, Andrea
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1912-1919
    • /
    • 2018
  • The output capacitance of power semiconductor devices is important in determining the switching losses and in the operation of some resonant converter topologies. Thus, it is important to be able to accurately determine the output capacitance of a particular device operating at elevated power levels so that the contribution of the output capacitance discharge to switch-on losses can be determined under these conditions. Power semiconductor switch manufacturers usually measure device output capacitance using small-signal methods that may be insufficient for power switching applications. This paper shows how first principle methods are applied in a novel way to obtain more relevant large signal output capacitances of Gallium-Nitride (GaN) FETs using the drain-source voltage transient during device switch-off numerically. A non-linear capacitance for an increase in voltage is determined with good correlation. Simulations are verified using experimental results from two different devices. It is shown that the large signal output capacitance as a function of the drain-source voltage is higher than the small signal values published in the data sheets for each of the devices. It can also be seen that the loss contribution of the output capacitance discharging in the channel during switch-on correlates well with other methods proposed in the literature, which confirms that the proposed method has merit.

A Study on Warnning Criteria Investigation of Automated Rainfall Warning System -Focused on Realationship of Water Level, Discharge and Precipitation - (자동우량경보시설 경보발령기준 검토 연구 - 수위, 유출량, 강수량의 관계를 중심으로 -)

  • Ahn, Jae-Chan;Lee, Jong-Seol;Chol, Woo-Chung;Lee, Byong-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.101-109
    • /
    • 2008
  • Automated rainfall warning system is a facility to prevent casualties who were recreating in the down stream region with operating lead broadcasting or signaling warning automatically when torrential rainfall occurs in mountainous area. But standard of conventional warning does not consider the characteristics of basin, and warning signal. Evacuation signal 1 and evacuation signal 2 are uniformly signaled when the 10minute moving total of observed rainfall is higher than 4 mm, 6 mm, and 8 mm respectively. therefore, local governments and relative agencies had re-established the standard of warning by analyzing the risk water level, critical discharge and reference rainfall, which are considering the characteristics of basin. In this study the standard of conventional and re-established warning of weolseong basin, which is available to acquire a real rainfall. There are analyzed by considering the risk water level, critcal discharge and reference rainfall. Also this study compares rainfall of conventional and re-established warning standard and indentifies problems by analyzing adequacy of rainfall estimation for warning and proposes alternative. The standard of conventional warning which investigates with the converted rainfall(unit of a minute) issued too many alarm. The re-established standard upward has the necessity which will be regulated about the alarm announcement number of times. Considers the safety, upward regulation of alarm standard rainfall is a necessity which will be prudent.

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

A Study on the Performance Evaluation of a Voice Coil Actuator for Electro-Discharge Micro-Drilling Machine (보이스코일 액츄에이터로 이송되는 미세구멍 가공용 방전 가공기의 작동특성 연구)

  • Yang, Seung-Jin;Baek, Hyeong-Chang;Kim, Byeong-Hui;Jang, In-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.152-158
    • /
    • 2001
  • In this paper, we have developed an electro discharge machine for micro drilling driven by a voice coil actuator. Because the voltage signal of the electro-discharging circuit shows a lot of peaks and valleys, the active type low-pass filtering technique is adopted to get the average of the signal. Since the motion of the voice coil is precisely controlled by the error value between the object voltage value and the measured one, it is possible to prevent the mechanical contact between the rotating electrode and the workpiece and to maintain the appropriate machining conditions during the process. The electro-chemical machining technology was also adopted to make small diameter electrodes. Pure water is used as a dielectric. The machining procedure is performed to verify the feasibility of the developed system. It takes about 10 seconds to drill the ${\phi}m$100${\mu}m$ hole to the 100${\mu}m$ thickness stainless steel plate. The machining time depends on the values of the resister and the capacitor. There may exist the optimal values of time constant and the tendency is displayed In the appendix.

  • PDF

A Study on the Predictive Diagnosis of the Cable Joint Using Ultrasonic Technique (초음파 측정기법을 사용한 케이블 접속부 예방진단 연구)

  • 곽희로;이동준;박동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.78-84
    • /
    • 2000
  • In this paper, the diagnosis technique was proposed by measuring and analyzing ultrasonic signals caused by partial discharge on the interface of cable joint. The measured ultrasonic signal was filtered by wavelet transform, and then the dominant signal of filtered signal was analyzed by fast fourier transform(FFT). As a result, it was confirmed that different characteristics were obtained with the moisture and the metal powder on the interface of cable joint and with voltage increment.

  • PDF

PD Measure and UV Detection in according to Withstand Voltage Characteristics of Polymer Insulator (폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Jong-Seo;Jung, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.76-77
    • /
    • 2008
  • The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7mV at 30kV to about 3mV at 70kV. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.

  • PDF

A Study on Diagnosis of Transformers Aging Sate Using Wavelet Transform and Neural Network (이산웨이블렛 변환과 신경망을 이용한 변압기 열화상태 진단에 관한 연구)

  • 박재준;송영철;전병훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.1
    • /
    • pp.84-92
    • /
    • 2001
  • In this papers, we proposed the new method in order to diagnosis aging state of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion skewness, kurtosis) about each acoustic emission signal. Also, these coefficients are used to identify normal and fault signal of internal partial discharge in transformer. As improved method for classification use neural network. Extracted statistical parameters are input into an back-propagation neural network. The number of neurons of hidden layer are obtained through Result of Cross-Validation. The network, after training, can decide whether the test signal is early aging state, alst aging state or normal state. In quantity analysis, capability of proposed method is superior to compared that of classical method.

  • PDF

The Analysis of PD Signal using Neural Network (신경회로망을 이용한 부분방전 신호의 패턴분석)

  • 김종서;박용필;천민우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.567-571
    • /
    • 2004
  • Recently, GIS(Gas Insulated Switchgear) has been recognizing of importance on development of diagnosis technique which is happened problem on confidence for a long time use. Therefore, the measurement and analysis of PD with prior phenomenon of insulation breakdown is used many method of diagnosis for GIS. In this paper, we simulate trouble condition in DS and analysis trouble signal to use electrical and mechanical methods, interpretation of detected signal has analysed with to use ø-q-n pattern and neural network. For this analysis, we have used the induction and AE(acoustic emission) sensors. For the simulation experiment, we make DS for 170 KV GIS and analyze the classification and characteristics of detected signals with the application of neural network algorithm.

Diagnosis for Degradation of Transformer Oil by an Optical Fiber Sensor (광섬유 센서를 이용한 변압기 절연유의 열화 진단)

  • Yi, Sue-Muk;Kim, Tae-Young;Suh, Kwang-S.;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1563-1565
    • /
    • 2000
  • This paper presents the preliminary results on the application of optical fiber sensor(OFS) for the diagnosis of degradation in the transformer oil. An OFS system using a Mach-Zehnder interferometry technique was built to detect attenuation of acoustic signal produced by discharging. With increasing the number of discharging in the insulation oil, the attenuation of acoustic signal became greater. A strong correlation between electrical and acoustic signal intensities from discharge generated in the transformer oil was confirmed by the results reported here.

  • PDF