• Title/Summary/Keyword: discharge signal

Search Result 409, Processing Time 0.035 seconds

Diagonoses of Power Transformer Using Acoustic Emission Techniques (음향기술을 이용한 전력용 변압기 예방진단)

  • Hwang, S.J.;Kwak, H.R.;Jeon, H.J.;Kim, J.C.;Park, J.W.;Choi, S.A.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.938-941
    • /
    • 1992
  • This paper presents an acoustic emission(AE) technique using ultrasonic sensors to diagonize power transformers. Conventional methods detect and measure the electrical signal of the partial discharge(PD) of transformers in operation. The proposed techniques measures the acoustic signal generated by the partial discharge, and counts the number of the waveforms above a threshold to diagonize transformers. Experiments showed that the proposed method improved diagonosis capability over the conventional PD method.

  • PDF

Localization of partial discharge in power transformer by detecting UHF PD signal (UHF 부분방전 신호를 이용한 전력용 변압기 내부의 부분방전 위치 추정)

  • Ju, Hyung-Jun;Goo, Seun-Gun;Han, Ki-Sun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.147-148
    • /
    • 2008
  • In this paper two kinds of techniques were compared for localization of PD(partial discharge) in power transformer and more useful method was suggested. Both of them, the time of arrival and the energy content method, were tested in 154kV single phase experimental transformer using UHF signal measurement. The former was using the difference of arrival time of recorded signals from four UHF sensors, the latter was based on the energy content in frequency spectra of signals detected at all sensors.

  • PDF

The Optimal Frequency Domain Choice to Measure Partial Discharge in Rotator Machine (회전기 부분방전신호 측정을 위한 최적 주파수 영역 선정)

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2052-2053
    • /
    • 2007
  • Recently, the importance of supplying the reliable electric power is increasing. Breaking insulation of stator winding is major cause of fault in rotator machine. On-line PD detecting is useful technique to diagnose rotator machine. However, interpretation of its results in time domain is very complex because of the mixed results with PD(Partial Discharge) and noise signal. Therefore, the results were analyzed in frequency domain by FFT (Fast Fourier Transform) to detect precise PD signals. The purpose of this paper is to describe the optimal frequency range to discriminate the PD and noise signal.

  • PDF

Characteristics of Partial Discharges Signals Utilizing Method of Wavelet Transform Denoising Process (웨이브렛 변환의 노이즈 제거기법에 의한 부분방전신호 특성)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.62-68
    • /
    • 2001
  • In this paper, As the wavelet transform has the properties of multi-resolution analysis and time-frequency domain localization, application of wavelet transform is used at partial discharge(PD) signal detected by electrical detection method to extract PD signal's various frequency component and its time domain. therefore we can analyzed PD signal's time-frequency domain simultaneously. On the other hand, using wavelet transform denoising process, included noise signal in detected PD signal is well eliminated. we can propose the true shine of PD signal.

  • PDF

The Noise Pattern Analysis at Partial Discharge Signal of High Voltage Rotator (고압 회전계 부분방전 신호의 노이즈 특성 분석)

  • Shin, Hee-Sang;Cho, Sung-Min;Kang, Chul;Kim, Jae-Chul;Kang, Dong-Sik;Cho, Kook-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.287-290
    • /
    • 2007
  • This study examines the characteristics of noise occerred at a hydroelectric power plant by using the on-line partial discharge measured by eletrical detecting method under the high voltage rotating machines. In addition, it analyzes the noise pattern into frequency and its scale component by using the FTT technique.

  • PDF

Filter Design for High-Frequency Partial Discharge (고주파 부분 방전을 위한 필터 설계)

  • Oh, Yong;Gil, Hyoung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.239-242
    • /
    • 2008
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke probe and oscilloscope (TDS-3054, Tektronix).

  • PDF

Recognition of Partial Discharge Patterns using Classifiers and the Neural Network (신경회로망과 Classifier를 이용한 부분방전패턴의 인식)

  • 이준호;이진우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.132-135
    • /
    • 1999
  • In this work, two approaches were proposed for the recognition of partial discharge patterns. The first approach was neural network with backpropagation algorithm, and the second approach was angle calculation between two operator vectors. PD signal were detected using three electrode systems; IEC(b), needle-plane and CIGRE method II electrode system. Both of neural network and angle comparison method showed good recognition performance for the patte군 similar to the trained patterns. And the number of operators to be used had a great influence on the recognition performance to the untrained patterns.

  • PDF

Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears (가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발)

  • Choi, Jae-Ok;Kim, Young-No;Lee, Young-Sang;Gang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Koo, Jae-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1963-1966
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.