• Title/Summary/Keyword: discharge resistance

Search Result 499, Processing Time 0.029 seconds

A study on High Voltage Squarewave Pulse Generator (고전압 구형파 펄스 발생기에 관한 연구)

  • Kim, Young-Bae;Ryu, Hong-Je;Kim, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1022-1025
    • /
    • 2008
  • This paper presents the generation of the high voltage squarewave pulse using distributed RLC circuit. The demonstrated test was performed with the distributed RLC circuit which consists of the resistance, the inductance and the capacitance. Pspice simulation was also conducted about the experiment circuit. The result of the experiment was in good agreement with the result of the simulation. Theoretical analysis of the initial peak value at the squraewave pulse was derived from the results of the experiment and simulation. Additionally, the characteristics of the time delay was analyzed about the spherical gap switch and the surface discharge gap switch, respectively. It is concluded that the surface discharge gap switch is better than the spherical gap switch to reduce the time delay.

Improvement of Electrochemical Reaction Kinetics in Lithium Manganese Oxide Thin Films (리튬 망간산화물 박막에서의 전극 반응의 개선)

  • Park Young-Shin;Kim Chan-Soo;Joo Seung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.96-99
    • /
    • 2000
  • In order to improve the rate capability of lithium manganese oxide thin film, we prepared the patterned cathode films by conventional lithography and etching techniques. From the investigation of discharge current density effects on discharge curves of cathode films, the rate capability was greatly improved due to increase of lithium intercalation kinetics fur charge transfer.

Application of Three-Dimensional Model to Evaluate Stream Discharge Capacity due to Vegetation (식생분포에 따른 하도의 통수능 검토를 위한 3차원 모형의 적용)

  • Noh, Joon Woo;Lee, Jin Young;Ahn, Ki Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.37-48
    • /
    • 2011
  • Recently, the social and environmental functions of nature river are important due to the increase of expectation for river restoration. So it should be considered the effect of vegetation affecting the conveyance capacity and hydraulic resistance. However, it has not yet proposed a objective standard and modeling method to estimate the effect of conveyance capacity according to vegetaion distribution in the watercourse such as water level or velocity. Therefore, this study simulates the variations of water level and velocity using 3-dimensional hydrodynamic model, EFDC, to consider a conveyance capacity in downstream of the Soyang Reservoir. The simulation results were validated using statistical index such as F-test and T-test. As results, the water level rises about 0.01 to 0.47m and velocity difference are about -0.95m/s to 0.23m/s.

Theoretical Modeling of Pulsed Plasma Thruster Performance with Teflon Ablation

  • Cho, Mingyoung;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.138-143
    • /
    • 2017
  • A performance analysis for a pulsed plasma thruster(PPT) has been conducted to predict the thrust and current change. Two models were implemented - a one-dimensional lumped circuit analysis model and the Teflon ablation model provided by Michael Keidar. The circuit model incorporating resistance and inductance models was adapted to predict the magnitude of the discharge current. Numerical simulations like current discharge rates with different voltages were reasonably well compared with experimental data. The effects of Teflon ablation on thruster characteristics were investigated.

A Design of BJT-based ESD Protection Device combining SCR for High Voltage Power Clamps

  • Jung, Jin-Woo;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • This paper presents a novel bipolar junction transistor (BJT) based electrostatic discharge (ESD) protection device. This protection device was designed for 20V power clamps and fabricated by a process with Bipolar-CMOS-DMOS (BCD) $0.18{\mu}m$. The current-voltage characteristics of this protection device was verified by the transmission line pulse (TLP) system and the DC BV characteristic was verified by using a semiconductor parameter analyzer. From the experimental results, the proposed device has a trigger voltage of 29.1V, holding voltage of 22.4V and low on-resistance of approximately $1.6{\Omega}$. In addition, the test of ESD robustness showed that the ESD successfully passed through human body model (HBM) 8kV. In this paper, the operational mechanism of this protection device was investigated by structural analysis of the proposed device. In addition, the proposed device were obtained as stack structures and verified.

Propagation Characteristics of Surge Generated due to Internal Arc Discharge in Superconducting Magnet (초전도 마그네트 시스템 내부 아크방전에 의한 발생 서어지의 전파특성)

  • Choi, Byoung-Ju;Suehiro, Junya;Hara, Masanori
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1904-1906
    • /
    • 1996
  • Transient voltage distribution tests are carried out to evaluate effects of a high frequency oscillating voltage generated in a superconducting magnet as a result of the arc discharge extinction. Especially, the effects of temperature and conduction state of the magnet conductor on surge behavior are carefully investigated. Based on the results of simulation tests, it is shown that internal voltage waveforms are influenced by its transmission along the superconducting wire and reflection at the terminal and that attenuation process of the waveforms depends considerably on the conductor resistance which decreases with lowering the temperature.

  • PDF

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

Characteristics of MCMB Anode Mixed with KCF (MCMB 및 KCF 혼합부극의 특성 연구)

  • Jeong, Jae-Kook;Jin, Bong-Soo;Moon, Seong-In;Yoon, Mun-Soo;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.513-516
    • /
    • 2001
  • In this study, the properties of MCMB anode Mixed with KCF were evaluated, KCF material was used as not only conducting agent but also active material, The Electirc conductivity of MCMB and KCF were 23.7S/cm and 45.8S/cm. Characteristics of anode with different KCF contents were the best effect at 2wt%. The 1st Ah efficiency of cells were increased with increment of KCF contents. The internal resistance and the rate capability were $1.59{\Omega}$ and 135mAh/g at 2C, The discharge capacity was gradually faded with the charge-discharge cycling to about 50th cycles.

  • PDF

The dependence of the electrical characteristics of MgO on temperature in an AC PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.714-716
    • /
    • 2005
  • We studied the dependence of the electrical characteristics of MgO protecting layer on temperature in an AC PDP cell. Careful measurements of the surface resistance of MgO were performed for the temperature range from room temperature to $100^{\circ}C$ with and without the VUV illumination. Experimental results show that the resistivity is affected by not only the temperature but also VUV irradiation. The measurement of wall charge distribution and the address discharge delay time as to the temperature show that the resistivity change of MgO may affect the wall voltage and consequently the discharge delay time.

  • PDF

The Effect of Metallic Barrier on the Surface creeping Flash-over Voltage along the Insulation Materials (절연물의 연면섬락 전압에 미치는 금속 격벽의 영향)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.14 no.2
    • /
    • pp.8-13
    • /
    • 1965
  • It is expected that the impurities contained in a solid state insulation material will affect a considerable influence on its break-down voltage, dielectric loss, and insulation resistance. In this thesis, as a preliminary experimental research for the investigation described above, the effect of metalic barrier between the electrodes on the creepin flash over discharge voltage along the surface of a solid insulation material has been investigated, and got some interesting results. It was found that generaly the flash over voltage rises when a metalic barrier is located between the electrodes. The results of this investigation will be taken into account as an important components on the insulation design to prevent the creeping flash over discharge in insulators, bushings, and so on.

  • PDF