• 제목/요약/키워드: discharge cleaning

검색결과 92건 처리시간 0.025초

지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발 (Development of an ionic wind dust collector towards coronavirus reduction in subway stations)

  • 신동호;김영훈;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구 (A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation)

  • 최용준;최지혁;신용현;조형락;손진식;이상호
    • 멤브레인
    • /
    • 제26권1호
    • /
    • pp.70-75
    • /
    • 2016
  • 본 연구에서는 하수처리수를 원수로 사용하여 직접 접촉식 막증발법을 적용하여 원수 온도와 원수 유량 변화에 따른 하수처리수의 COD, TN, TP, TOC의 제거율 변화와 여과플럭스의 변화를 측정하였다. 또한 하수처리수에 의한 분리막의 오염 가역성을 평가하기 위해 1차 증류수만을 사용하여 물리세정을 수행한 후 플럭스의 회복률을 측정하였다. 실험결과 원수의 온도 및 유량에 관계없이 원수가 3배 농축될 때까지 여과를 진행하였음에도 불구하고 하수처리수의 주요 오염물질인 COD, TN, TP, TOC에 대한 제거율이 92% 이상으로 높게 나타났다. 또한 비교적 낮은 온도인 $50^{\circ}C$$60^{\circ}C$에서 원수의 유량에 따라 최소 13.8 LMH에서 20.3 LMH로 높은 여과플럭스를 나타냈다. 그리고 높은 농축계수까지 여과 실험을 진행했음에도 불구하고 낮은 여과플럭스의 감소를 나타냈으며 1차 증류수를 이용한 짧은 시간 동안의 물리세정만으로 최소 90% 이상의 높은 여과 플럭스 회복율을 나타냈다. 따라서 하수처리수 재이용을 위한 공정으로 막증발법의 적용이 충분히 가능할 것으로 판단된다.

생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구 (A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste)

  • 고성규;조용균;이영신
    • 유기물자원화
    • /
    • 제20권4호
    • /
    • pp.97-105
    • /
    • 2012
  • 본 연구는 음식물류 폐기물의 처리과정에서 발생하는 음식물류 폐수를 생활폐기물 소각시설에서 생활폐기물과 음식물류폐수를 혼합하여 소각처리 방법과 소각시 음식물류 폐수를 이용한 질소산화물 제거 및 배출가스의 영향등을 조사하였다. 해양투기용으로 발생된 음식물류폐기물 폐수는 성상이 94-96%의 함수율을 갖고 있다. 음식물류폐기물 폐수를 주입하였을 때 소각로 출구 온도는 $897^{\circ}C$이였으며, 평상시는 $925^{\circ}C$로 약 $28^{\circ}C$도 떨어졌다. 음식물류폐기물 폐수를 각각 $200{\ell}/hr$, $300{\ell}/hr$ 투입시 질소산화물의 평균배출농도는 각각 50ppm, 46ppm 이었다. 연관식 폐열보일러는 음식물류 폐수의 투입량이 많을수록 튜브 막힘 현상이 있었으며, 막힘 튜브는 압축공기를 이용한 튜브 청소로 원상태를 유지 할 수 있어 연속적 소각에는 방해가 되지 않았다. 유기성 폐기물인 음식물류 폐수의 자원화 처리방법과 더불어 기존 소각시설을 이용한 소각처리가 육상처리의 한 방법으로 자리매김 할 수 있으며, 소각시 배출가스의 질소산화물이 제거됨으로써 질소산화물 제거용 암모니아, 요소수 등 화학약품비용 절감하는 효과도 있는 것으로 나타났다.

선박용 디젤엔진의 NOx를 저감하기 위한 습식 배기가스 처리기술 적용에 관한 실험적 연구 (Experimental study of NOx reduction in marine diesel engines by using wet-type exhaust gas cleaning system)

  • 류영현;김태우;김정식;남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.216-221
    • /
    • 2017
  • 디젤엔진은 내연기관 중에 제동 열효율이 가장 높은 엔진이기 때문에 큰 동력을 필요로 하는 대형트럭과 같은 중 대형 운송 차량 및 선박 등의 수송분야 및 발전시스템 등의 다양한 분야에서 사용되어지고 있다. 하지만, 디젤엔진은 연소과정에서 질소산화물(이하 NOx) 발생량이 많은 단점을 가지고 있다. 따라서 본 연구에서는 선박용 디젤엔진의 NOx를 저감하기 위해서 습식 배기가스 처리 기술인 무격막식 해수 전기분해 방식을 이용하여 NOx 저감을 시도하였다. 실제 해수를 사용하여 디젤엔진에서 배출되는 유해가스에 전기 분해된 해수인 전해수를 분사하여 보았다. 전해수의 pH 농도 및 유효염소농도, 온도에 따른 NO 산화율 및 NOx 감소량을 조사하였다. 본 실험을 통해서 전해수의 pH가 약산성 영역일 경우가 중성일 경우보다 산화탑에서의 NO 산화율이 상승하였고, 유효염소농도가 높을수록 NO 산화율이 증가하는 것을 확인할 수 있었다. 또한, 전해수 온도는 NO 산화율에 영향이 없음을 추가적으로 확인할 수 있었으며 디젤엔진에서 생성된 배기배출물에 전해수를 분사함으로써 NOx가 저감됨을 확인할 수 있었다.

습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성 (SOx and NOx removal performance by a wet-pulse discharge complex system)

  • 박현진;이환영;박문례;노학재;유정구;한방우;홍기정
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.

자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 - (A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling -)

  • 김준현;장정우;김진호;박광덕
    • 상하수도학회지
    • /
    • 제34권2호
    • /
    • pp.93-104
    • /
    • 2020
  • As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.

무성방전 플라즈마 전극구조에 대한 질소산화물 제거효율 연구 (A Study on NOx Removal Efficiency Depending on Electrode Configurations of Silent Discharges)

  • Hyung-Taek Kim;Young-Sik Chung;Myung-Whan Whang;Elena. A. Filimonova
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.112-117
    • /
    • 2002
  • 무성 (유전체 장벽)방전기구의 질소산화물(NOx)제거효율에 대한 화학 반응역학의 전산모사 및 실험적 특성이 비교 조사되었다. 방전 전극구조에 따른 여러 종류의 유전체 장벽 방전기구가 구현되었으며 응용 방전환경 별 질소산화물(NOx)제거특성이 이론적, 실험적으로 고찰되었다. 전산모사 모델링은 유해 배가스에 대한 플라즈마 응용기구의 수학적 근접모델을 기초로 하였고 각 방전광(스트리머) 채널의 주 활성입자 생성에 의한 화학반응 종들의 비균일, 비평형 분포특성을 고려하였다. 모델링 전산모사로 얻어진 질소산화물(NOx) 제거효율은 관찰 실험특성과 오차 허용범위 내의 일치성을 나타내었다.

기류방출형 연X선 조사에 의한 정전기 제거 장치에 관한 연구 (A Study on the Removal of Electrostatic using Transmitted Ions Generated Soft X-ray with Compressed Air)

  • 귄승열;이동훈;최재욱;서민석
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.27-31
    • /
    • 2010
  • It is a well known fact that the LCD and Semiconductor Devices are a central part of IT industry which is important in the present and the future. But the biggest problem of Semiconductor and LCD manufacturing is maintaining a cleaning room environment. For this reason, the soft X-ray type Ionizer was used as the electrostatic reducer device, which protects damage of the product against electrostatic discharge in the manufacturing process. Therefore it is a essential important factor during Semiconductor and LCD production process. But the soft X-ray has a intrinsic problem with harmful to human being in case of soft X-ray exposure. That's reason we have the research to solve above problem and made an apparatus that it was covered with shielding structure to protect X-ray radiation to outside. And besides, it has a possibility to eliminate the charged electrostatic in the narrow space through the slot for Ion emissions with dual soft X-ray sources on the both side. It is also not make the particles from itself when it has been operated.

아동전문병원 입원환아 부모의 병원서비스 만족도 (Parent Satisfaction with Inpatient Hospital Services in Children's Hospitals)

  • 정용선;김진선
    • Child Health Nursing Research
    • /
    • 제11권3호
    • /
    • pp.273-281
    • /
    • 2005
  • Purposes: The purposes of this study were to evaluate parent satisfaction with inpatient hospital services in children's hospitals and to identify variables related to parent satisfaction. Method: A descriptive correlation study was conducted. Parents of 165 children who were inpatients in two children's hospitals participated in the study. Data were collected using structured questionnaire at the time of discharge. For statistical analysis, t-test, ANOVA, and Pearson correlation analysis were used. Results: The highest parent satisfaction domain was nursing service, and the lowest parent satisfaction domain was hospital service and accommodations. Parents were less likely to be satisfied with hospital facilities, equipment, noise and cleaning and less likely to be satisfied with the lack of information they received and with the lack of communication with health care professionals. Parents with longer length of stay and with older children reported higher satisfaction than their counterparts. Moreover, parent satisfaction was related to their intention to revisit and related to intention to recommend this surveyed hospital over others. Conclusions: Efforts to improve parent satisfaction in children's hospital service and accommodation are needed to improve the quality of health care. Communication by health care professionals with parents and a partnership between parents and health care professionals are necessary to improve quality of care.

  • PDF

합성섬유 충진 여과수로를 이용한 건설사업장의 흙탕물 처리 및 배수구 보호에 관한 실험적 연구 (Experimental Study on Synthetic Fiber Filled Channel for Treating Turbid Water at the Construction Sites and Protecting Drain System)

  • 원경과;청징;박기수;김영철
    • 한국물환경학회지
    • /
    • 제32권6호
    • /
    • pp.537-545
    • /
    • 2016
  • In order to cope with the new and strict government regulations for turbid water discharge from construction sites, this study tested whether synthetic fiber filters can replace conventional best management practices. The filter efficiency was about 10 to 60% with a varying filter depth of 5 to 15cm, presuming extreme storm flow conditions to be in the range of 800 to 1500m/day of filtration rates. Fiber filter acts exactly like a granular filter, i.e. the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. Based on the operational data, we suggested the Log-Log design relationship, which can be used to determine the filter depth and area. Compared to the widely used gravel filter which treats the turbid water at the construction site, about 20% higher efficiency was obtained under similar operating conditions. Cleaning the filter through a simple hand-washing method at the time of break-through, achieved about 90% soil recovery.