• 제목/요약/키워드: discharge cleaning

검색결과 92건 처리시간 0.031초

활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성 (Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon)

  • 변정훈;황정호;지준호;강석훈
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구 (A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source)

  • 김규식
    • 전자공학회논문지SC
    • /
    • 제45권5호
    • /
    • pp.44-51
    • /
    • 2008
  • UV 램프 시스템은 오랫동안 TFT LCD 나 PDP 의 패널 세정에 사용되어 왔으나, 저렴한 가격의 고성능 세정에 대한 필요성 때문에 고전압 플라즈마 세정에 대한 기술이 개발되고 그 성능이 향상되어 왔다. 장벽방전 (barrier discharge) 혹은 무성방전 (silent discharge)으로 불리는 유전체 장벽 방전 (Dielectric-Barrier Discharges, DBDs) 는 오존 발생기에 주로 이용되어 왔다. 본 논문에서는 LCD 세정용으로 6kW 급 고전압 플라즈마 발생장치를 구현하였다. 3상 입력전압을 직류로 정류한 뒤, 인버터 시스템에 의해 고주파 펄스로 바꾸고 고압 트랜스퍼머를 거쳐 다이오드로 정류한다. 마지막으로, 고압 플라즈마를 발생시키기 위해 양방향 고전압 펄스 스위칭회로가 사용되었다. 실험을 통해 상압 플라즈마가 LCD 패널 세정에 크게 유용함을 보였다.

수중방전에 의한 압력분포의 2차원 해석 (Two-Dimensional Analysis of Pressure Distribute by Underwater Electric Discharge)

  • Kim, Y.S.
    • 한국정밀공학회지
    • /
    • 제12권1호
    • /
    • pp.68-77
    • /
    • 1995
  • The two-dimensional pressure distribution, which is the most important parameter in the casting cleaning installations(CCI), was analyzed using the K-FIX computer program for two-phase flow. Modelling was done using R-Z coordinates for the initial and boundary conditions which don't have periodic influx and efflux, and also there was the electric discharge due to high pressure and temperature. The marked particles were introduced to prodict the structure and the size of main and local moving surfaces. The initial and boundary conditions were modified due to the internal structure of CCI.From the results of numerical analysis, it was shown that the maximum pressure on casting was increased with the increase of a water level. The pressure on casting in the radial direction was higher than that in axial direction. Also, it was proved that by introducing the marked particles it was possible to predict the surface structure in case of two-phase flow.

  • PDF

상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구 (Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes)

  • 서지원;이규상;김기범;형진석;김태현;구자용
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

도로청소에 의한 비점오염부하 삭감량 산정방법 연구 (A Study on Estimating Diffuse Pollution Loads Removal by Road Vacuum Cleaning)

  • 이태환;조홍래;정의상;구본경;박배경;김용석
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.123-129
    • /
    • 2017
  • The purpose of this study is to identify potential methodologies to reasonably estimate the effectiveness of road vacuum cleaning in terms of pollution loads reduction. In this context, this study proposes two empirical equations to estimate the amount of diffuse pollution loads removed by road vacuum cleaning. The proposed equations estimate the removed amount of pollution loads respectively taking into consideration of: a) the distance of road vacuum cleaning; and b) the amount of road-deposited sediment(RDS). All of the parameters in these equations were evaluated based on results of field monitoring and laboratory analyses, except for the RDS generation rate. The results of this study suggest that pollutant removal efficiency is 46.3% for $BOD_5$ and 56.4% for TP; discharge ratios for particulate and dissolved $BOD_5$ are 35.0% and 21.2%, respectively; discharge ratios for particulate and dissolved TP are 35.0% and 19.4%, respectively. Average concentrations of pollutants in RDS are $BOD_5$ 977.3 mg/kg and TP 317.6 mg/kg. Some results of a case study imply that both equations can be potentially useful if the adopted parameters are reasonably evaluated. In particular, the RDS generation rate should be evaluated based on monitoring data collected from various road conditions.

Surface Cleaning of Polyethylene Terephthalate Film with Non-equilibrium Atmospheric Discharge Plasma

  • Sung, Youl-Moon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.79-83
    • /
    • 2008
  • The dampness by treating the surface with polyethylene terephthalate (PET) film was measured to grasp the plasma parameters and was observed the surface condition with an atomic force microscope (AFM) to find the causes of the dampness. Also, the vibrational and rotational temperatures in the plasma were calculated after identifying the radicals within the plasma by analyzing the emission spectral with an emission spectrum. The hydrophilic properties were enhanced, by treating the surface of the PET film with non-equilibrium atmospheric discharge plasma. When the rotational temperature was 0.22 to 0.31 eV within the plasma, surface modification control could be easily carried out to surface treatment of PET film on non-equilibrium atmospheric pressure plasma.

실리콘 Intrinsic Gettering 기술의 이해와 응용 (Silicon Intrinsic Gettering Technology: Understanding and Practice)

  • 최광수
    • 한국재료학회지
    • /
    • 제14권1호
    • /
    • pp.9-12
    • /
    • 2004
  • Metallic impurities, such as Fe, Cu, and Au, become generation and recombination centers for minority carriers when combined with oxide precipitates or silicon self-interstitial clusters. As these centers may cause leakage and discharge in silicon devices, their prevention through gettering of the metallic impurities is an important issue. In this article, key aspects of intrinsic gettering, such as oxygen control, wafer cleaning, device area denudation, and bulk oxygen precipitation are discussed, and a practical method of implementing intrinsic gettering is outlined.

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구 (Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge)

  • 정경재;이석근;당정증;최길환;황용석;김철영;박영준
    • 지질공학
    • /
    • 제23권1호
    • /
    • pp.29-36
    • /
    • 2013
  • 스크린 공막힘에 의하여 채수량이 감소된 지하수 관정은 여러 방법을 통하여 재생시켜주면 지하수 채수량을 개선시켜 관정의 수명을 연장할 수 있다. 본 논문에서는 화약이나 압축 유체를 사용하는 기존의 공막힘 재생기술을 대신할 수 있는 고전압 펄스 방전에 의한 지하수 관정 스크린 공막힘의 재생법에 대하여 연구하였다. 본 기술은 수중에 삽입된 전극에 순간적으로 고전압의 전기에너지를 주입하여 이 때 전극 사이에서 발생하는 고온, 고압의 플라즈마의 팽창력에 의하여 발생하는 수중 충격파를 이용하는 기술로, 기존 기술 대비 취급이 용이하며 구조가 간단하고 충격압의 크기 조절이 용이하다는 장점을 갖는다. 본 연구에서는 축전기 방전형 펄스 발생장치를 사용하여 약 200 J의 전기에너지를 수중에 삽입된 전극에 순간적으로 주입함으로써 전극으로부터 6 cm 떨어진 곳에서 약 10.7MPa의 수중 충격압을 얻었다. 이 충격압의 크기는 축전기의 충전 전압을 바꿔줌으로써 손쉽게 조절이 가능하였으며, 다양한 전압에서의 실험을 통하여 방전 전류의 첨두치와 선형적인 관계를 갖고 있음을 알았다. 또한 지하수 관정에 사용되는 스크린과 유사한 시료에 대한 모의실험을 통하여 이 기술을 이용한 지하수 관정의 세척 가능성을 확인하였다.

애자 표면열화에 의한 방전특성과 ICP-AES 분석 (The discharge characteristics and ICP-AES analysis of insulators by surface deterioration)

  • 송길목;김영석;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1408_1409
    • /
    • 2009
  • It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.

  • PDF