• 제목/요약/키워드: direct digital radiography

검색결과 59건 처리시간 0.032초

CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구 (Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries)

  • 이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

직.간접디지털 파노라마 방사선촬영시 흡수선량과 유효선량 (Absorbed and effective dose in direct and indirect digital panoramic radiography)

  • 이근선;김진수;김재덕
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.9-14
    • /
    • 2010
  • Purpose : We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. Materials and Methods : The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), $^nLi_2B_4O_7$ TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. Results : The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p<0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. Conclusion : The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구 (COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES)

  • 조영곤;박시승
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

디지털 방사선영상 시스템의 기본적 원리 (Physical principles of digital radiographic imaging system)

  • 최진우;이원진
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

  • Mohtavipour, Seiedeh Tahereh;Dalili, Zahra;Azar, Nasim Gheshlaghi
    • Imaging Science in Dentistry
    • /
    • 제41권1호
    • /
    • pp.7-10
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. Materials and Methods : Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-$15^{\circ}$, 15-$30^{\circ}$, > $30^{\circ}$). After the placement of a 15 K-file, radiographs were taken with a conventional film (Fspeed) and a digital sensor. Canal lengths were measured in these images by two observers. Statistical analysis was performed with repeated measures of ANOVA and paired sample t-test with 95% confidence. Results : There was a high inter-observer agreement on the measurements of working length in conventional and digital radiographs. There was no significant difference between the mean values of measurements in conventional and digital radiography. Moreover, there was no significant difference between conventional and digital radiography with the actual values in the basis of canal curves. Conclusion : The accuracy of conventional and digital radiography in the determination of the working length was in an acceptable range.

The Study of Acquisition Signal Distortion due to Edge Effect in Direct Digital Radiography System

  • Cho, Jin-Wook;Choi, Jang-Yong;Mun, Chi-Woona;Lee, Hyung-Won;Nam, Sang-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.179.1-179
    • /
    • 2001
  • Successive image contrast enhancement was used to direct digital radiography system. This system was accurately required acquisition signal in each pixel. But, applied high electric field in a-Se thin film for x-ray conversion layer was caused to acquisition signal distortion, then bring low image contrast. The purpose of this study was to reduce the signal distortion, carried out different electrode size.

  • PDF