• Title/Summary/Keyword: diode laser

Search Result 1,017, Processing Time 0.022 seconds

Measurement of Grating Pitch Standards using Optical Diffractometry and Uncertainty Analysis (광 회절계를 이용한 격자 피치 표준 시편의 측정 및 불확도 해석)

  • Kim Jong-Ahn;Kim Jae-Wan;Park Byong-Chon;Kang Chu-Shik;Eom Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.72-79
    • /
    • 2006
  • We measured grating pitch standards using optical diffractometry and analyzed measurement uncertainty. Grating pitch standards have been used widely as a magnification standard for a scanning electron microscope (SEM) and a scanning probe microscope (SPM). Thus, to establish the meter-traceability in nano-metrology using SPM and SEM, it is important to certify grating pitch standards accurately. The optical diffractometer consists of two laser sources, argon ion laser (488 nm) and He-Cd laser (325 nm), optics to make an incident beam, a precision rotary table and a quadrant photo-diode to detect the position of diffraction beam. The precision rotary table incorporates a calibrated angle encoder, enabling the precise and accurate measurement of diffraction angle. Applying the measured diffraction angle to the grating equation, the mean pitch of grating specimen can be obtained very accurately. The pitch and orthogonality of two-dimensional grating pitch standards were measured, and the measurement uncertainty was analyzed according to the Guide to the Expression of Uncertainty in Measurement. The expanded uncertainties (k = 2) in pitch measurement were less than 0.015 nm and 0.03 nm for the specimen with the nominal pitch of 300 nm and 1000 nm. In the case of orthogonality measurement, the expanded uncertainties were less than $0.006^{\circ}$. In the pitch measurement, the main uncertainty source was the variation of measured pitch values according to the diffraction order. The measurement results show that the optical diffractometry can be used as an effective calibration tool for grating pitch standards.

A Study on Selective Transfer and Reflow Process of Micro-LED using Micro Stamp (마이크로 스탬프를 이용한 Micro-LED 개별 전사 및리플로우 공정에 관한 연구)

  • Han, Seung;Yoon, Min-Ah;Kim, Chan;Kim, Jae-Hyun;Kim, Kwang-Seop
    • Tribology and Lubricants
    • /
    • v.38 no.3
    • /
    • pp.93-100
    • /
    • 2022
  • Micro-light emitting diode (micro-LED) displays offer numerous advantages such as high brightness, fast response, and low power consumption. Hence, they are spotlighted as the next-generation display. However, defective LEDs may be created due to non-uniform contact loads or LED alignment errors. Therefore, a repair process involving the replacement of defective LEDs with favorable ones is necessitated. The general repair process involves the removal of defective micro-LEDs, interconnection material transfer, as well as new micro-LED transfer and bonding. However, micro-LEDs are difficult to repair since their size decreases to a few tens of micron in width and less than 10 ㎛ in thickness. The conventional nozzle-type dispenser for fluxes and the conventional vacuum chuck for LEDs are not applicable to the micro-LED repair process. In this study, transfer conditions are determined using a micro stamp for repairing micro-LEDs. Results show that the aging time should be set to within 60 min, based on measuring the aging time of the flux. Additionally, the micro-LEDs are subjected to a compression test, and the result shows that they should be transferred under 18.4 MPa. Finally, the I-V curves of micro-LEDs processed by the laser and hot plate reflows are measured to compare the electrical properties of the micro-LEDs based on the reflow methods. It was confirmed that the micro-LEDs processed by the laser reflow show similar electrical performance with that processed by the hot plate reflow. The results can provide guidance for the repair of micro-LEDs using micro stamps.

Effects of 630-nm Organic Light-emitting Diodes on Antioxidant Regulation and Aging-related Gene Expression Compared to Light-emitting Diodes of the Same Wavelength

  • Mo, SangJoon;Kim, Eun Young;Ahn, Jin Chul
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.227-235
    • /
    • 2022
  • To investigate the aging-related physiological functions of organic light-emitting diodes (OLEDs), we examined mRNA expression changes in aging-related genes due to oxidative stress inhibition by 630-nm red light OLEDs. As a result of irradiating 630-nm OLED with an intensity of 5 mW/cm2 for 15 min, the viability of dermal fibroblasts significantly increased by 1.3-fold. In addition, reactive oxygen species generated by H2O2 were significantly reduced about 4.9-fold by irradiation with 630-nm OLED. Quantitative reverse-transcription polymerase chain reaction results showed that 630-nm OLEDs altered aging-related gene mRNA expression levels through antioxidant activity. The mRNA expression levels of matrix metalloproteinase1 (MMP1) and MMP9 decreased significantly, by about 2.2- and 2.5-fold, compared to the control group, whereas those of collagen, type I, and alpha 1 increased significantly, by 4.9-fold. The mRNA expression levels of cancer suppression genes p16 and p53 in dermal fibroblasts were also significantly reduced by 630-nm OLED irradiation, by about 1.4- and three-fold, respectively, compared to the control. Overall, it was confirmed that 630-nm OLED irradiation lowered the level of ROS formation induced by H2O2 in dermal fibroblasts, and that this antioxidant effect could regulate the mRNA expression levels of aging- and tumor suppression-related genes. This study shows a link between 630-nm OLED irradiation and anti-aging physiological functions such as antioxidant function, and suggests the potential of OLEDs as a useful light source for skin care.

High-beam-quality 2-kW-class Spectrally Combined Laser Using Narrow-linewidth Ytterbium-doped Polarization-maintaining Fiber Amplifiers (협대역 이터븀 첨가 편광유지 광섬유 증폭기를 이용한 고품질 2 kW급 파장제어 빔 결합 레이저)

  • Jeong, Hwanseong;Lee, Kwang Hyun;Lee, Junsu;Kim, Dong-Joon;Lee, Jung Hwan;Jo, Minsik
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.5
    • /
    • pp.218-222
    • /
    • 2020
  • In this paper, we have experimentally demonstrated a 2-kW-class spectrally-beam-combined laser with high beam quality, using narrow-linewidth ytterbium-doped polarization-maintaining fiber amplifiers. Five fiber amplifiers with different center wavelengths were implemented for the spectrally-beam-combined laser. The center wavelengths of the five amplifiers were 1062, 1063, 1064, 1065, and 1066 nm, respectively. A phase-modulated laser diode was used as a seed source for each amplifier. The seed sources were modulated by filtered pseudorandom-bit-sequence (PRBS) signals 5 GHz in linewidth. The polarization-maintaining large-mode-area fiber with a core size of 30 ㎛ was used as a delivery fiber to mitigate the stimulated Brillouin scattering (SBS) effect. The laser beams from five amplifiers were spectrally combined by a multilayer dielectric diffraction grating. The maximum output power and beam quality M2 of the combined laser were measured to be 2.3 kW and 1.74, respectively.

Effects of GaAs (904 nm) Low Level Laser Therapy on Dentin Hypersensitivity (과민치아에 대한 904nm GaAs 반도체레이저의 효과)

  • Won, Tae-Hee;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.215-224
    • /
    • 2011
  • The aim of the study was to investigate the effects of 904 nm GaAs laser irradiation for patients with hypersensitive teeth and to find the possibility of clinical use of this Low Level Laser Therapy (LLLT) for the control of hypersensitive teeth. Eleven patients visited Dept. of Oral Medicine, Dankook University participated in this study. Each patient contributed at least two or more contralateral pairs of hypersensitive teeth with exposed dentine at cervical surfaces. Total number of teeth used from subjects participated in this study was 50: 25 experimental and control teeth respectively. All participants were treated with 904 nm GaAs diode laser every week during 4 weeks. Tactile and cold (ice stick) tests were carried out before LLLT every week during 4 weeks and 1 week later after the last LLLT by measuring visual analogue scale (VAS) of patients and by measuring a score of electrical pulp tester (EPT) simultaneously. The VAS score in tactile test decreased significantly with time, but there was not statistically difference between those of groups. The score of EPT in the experimental group was significantly higher than that of control group, although there was no change with time. In cold test, there was significant difference between two groups and cold sensitivity of the experimental group significantly decreased with time after every LLL irradiation, compared with that of control group. Based on the results, it is suggested that the 904 nm GaAs laser irradiation could be positively used as an effective, reversible method in treating cervical dentine hypersensitivity.

Fabrication and performance analysis of cost-effective fiber grating lasers for WDM-PON systems (WDM-PON 시스템용 저가형 Fiber Grating Laser의 제작 및 성능 분석)

  • Cho, Seung-Hyun;Lee, Woo-Ram;Lee, Jie-Hyun;Park, Jae-Dong;Kim, Byoung-Whi;Kang, Min-Ho;Shin, Dong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.13-20
    • /
    • 2005
  • Fiber-Bragg-grating external cavity laser(FGL) modules were fabricated and experimentally analyzed. Proposed as a cost-effective solution for optical sources in the WDM-PON access network, FGL modules were packaged to TO-CAN type. We obtained a low threshold current of 13 mA, and an optical output power of 3.6 mW with a bias current of 60 mA at $25^{\circ}C$. The lasing wavelength dependencies on current and temperature were as small as 5.2 pm/mA and 30 pm/$^{\circ}C$, respectively. These change rates of the wavelength with the temperature and current are smaller than those of the DFB laser. Single-mode oscillations with the side-mode suppression ratio(SMSR) over 30 dB are maintained above the threshold current level. The FGL modules can be directly modulated at 155 Mbps, PRBS(2$^{23}$ -1) NRZ signal. Through the BER plots, we did not see the significant degradations before and after the transmission over 20km of the SMF at 155 Mb/s.

A study on measurement of oxygen in a reheating furnace using TDLAS (가열로에서 TDLAS를 이용한 각대산소농도측정에 관한 연구)

  • Kim, Young-Il;Kim, Ki-Hong;Lee, In-Bum
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.160-167
    • /
    • 2006
  • In this project, we studied more accurate and reliable sensing method for oxygen in reheating furnace, made the empirical model for NOx concentration based on oxygen and evaluate the stability of the Tuneable Diode Laser (Absorption) Spectroscopy(TDL(A)S). The tested oxygen monitoring system is installed at work-field reheating furnace on hot roll at POSCO and compared with the Zr sensor system which shows too sensitive because it measures oxygen concentration on a spot unlike TDLS sensor which is successfully applied at 13m-width reheating furnace to measures the line average along the Optical Path Line(OPL).

  • PDF

High resolution Linear Encoder Using Interference Fringe (레이저의 간섭무늬를 이용한 리니어 엔코더에 관한 연구)

  • 박윤창
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.130-135
    • /
    • 1999
  • The main scale of linear encoder greatly effects on the precision of displacement measurement. Especially when needing the long range measurement the length of main scale should be increased accordingly. In this paper we propose a linear encoder that uses laser interference pattern as main scale for long range measurement. The linear encoder is similar to Michelson interferometer excepting that the reference mirror is tilted so as to obtain interference fringe pattern and a grating panel is attached on a quadratic photo diodes. Four kinds of grating having phase difference of 0. $\pi$/4, $\pi$/2, 3$\pi$/4 are arranged on the panel. The experimental results show that signals of quadratic photo diode A, B, {{{{ {-}atop {A } }}}} and {{{{ {- } atop {B } }}}} are cosine wavelike and successive signals have phase difference of $\pi$/4 each other. So the proposed method can achieve improved measurement resolution.

  • PDF

Depleted Optical Thyristor using Vertical-Injection Structure for High Isolation Between Input and Output (완전공핍 광 싸이리스터에서 입출력의 높은 아이솔레이션을 위한 수직 입사형 구조에 관한 연구)

  • Choi Woon-Kyung;Kim Doo-Gun;Moon Yon-Tae;Kim Do-Gyun;Choi Young-Wan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.30-34
    • /
    • 2005
  • This study shows the lasing characteristics of InGaAs/InGaAsP multiple-quantum-well waveguide-type depleted optical thyristor (DOT) using the vertical window. The measured switching voltage and current are 3.36 V and 10 ㎂, respectively. The lasing threshold current is 131 mA at 25 ℃. The output peak wavelength is 1570 nm at a bias current of 1.22 Ith and there is not input signal anymore in the output port. The vertical injection depleted optical thyristor - laser diode (VIDOT-LD) using the vertical-injection structure shows very good isolation between input and output signal.

Miniature Fluorescence Detection System for Protein Chips by Prism (프리즘을 이용한 소형 단백질칩 분석 형광측정 시스템 개발)

  • Choi, Jae-Ho;Kim, Ho-Seong;Lee, Kook-Nyung;Kim, Eun-Mi;Kim, Yong-Kweon;Kim, Byung-Gee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2040-2042
    • /
    • 2004
  • This paper presents a miniature optical system for the fluorescence detection of the patterned protein chip. The patterned protein chip was fabricated using MEMS process. The fluorescence from the patterned protein chip was measured while varying the concentration of the BSA. The fluorescence light is separated spatially from the excitation beam using mini-size prism to increase SNR (Signal-to-Noise Ratio). The combination of prism and mirrors can convert the excitation light from the laser diode to uniform illumination on the specimen. We believe that the proposed system for fluorescence detection can be applied to rea1ization of point-of-care.

  • PDF