A study on measurement of oxygen in a reheating furnace using TDLAS

가열로에서 TDLAS를 이용한 각대산소농도측정에 관한 연구

  • 김영일 (포항산업과학연구원 에너지연구실, POSTECH 화학공학과) ;
  • 김기홍 (포항산업과학연구원, 에너지연구실) ;
  • 이인범 (POSTECH 화학공학과)
  • Published : 2006.10.20

Abstract

In this project, we studied more accurate and reliable sensing method for oxygen in reheating furnace, made the empirical model for NOx concentration based on oxygen and evaluate the stability of the Tuneable Diode Laser (Absorption) Spectroscopy(TDL(A)S). The tested oxygen monitoring system is installed at work-field reheating furnace on hot roll at POSCO and compared with the Zr sensor system which shows too sensitive because it measures oxygen concentration on a spot unlike TDLS sensor which is successfully applied at 13m-width reheating furnace to measures the line average along the Optical Path Line(OPL).

Keywords