• Title/Summary/Keyword: dilution method

Search Result 814, Processing Time 0.031 seconds

Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field (반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰)

  • Kim, Joung-Cho;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.

Generation of Nano/Submicron Particles Using an Electrically Heated Tube Furnace (전기가열 튜브로를 이용한 나노/서브마이크론 입자의 발생)

  • Ji, Jun-Ho;Pae, Yang-Il;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1734-1743
    • /
    • 2003
  • Aerosol generator using an electrically heated tube furnace is a stable apparatus to supply nanometer sized aerosols by using the evaporation and condensation processes. Using this method, we can generate highly concentrated polydisperse aerosols with relatively narrow size distribution. In this work, characteristics of particle size distribution, generated from a tube furnace, were experimentally investigated. We evaluated effects of several operation parameters on particle generation: temperature in the tube furnace, air flow rates through the tube, size of boat containing solid sodium chloride(NaCl). As the temperature increased, the geometric mean diameter increased and the total number concentration also increased. Dilution with air affected the size distribution of the particles due to coagulation. A smaller sized boat, which has small surface area to contact with air, brings smaller particles of narrow size distribution in comparison of that of a larger boat. Finally, we changed the electrical mobility diameter of aggregate sodium chloride particles by varying relative humidity of dilution air, and obtained non-aggregate sodium chloride particles, which are easy to generate exact monodisperse particles.

Decolorization of Dye and Molasses by Continuous and Semi-Continuous Jar-Fermentor Cultures of Geotrichum candidum Dec 1

  • Kim, S.J.;Kim, M.J.;Shoda, M.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.4
    • /
    • pp.306-312
    • /
    • 2006
  • Two culture modes, continuous and semi-continuous, of the decolorization fungus, Geotrichum candidum Dec 1, were compared to obtain a high treatment efficiency of molasses decolorization and a large productivity of peroxidase (DyP) to simultaneously decolorize dyes and molasses. The continuous culture of G. candidum Dec 1 using a 5-I jar-fermentor showed high DyP activity at a low dilution ratio of $0.005h^{-1}$, and decolorization ratio of molasses of 80% was obtained concomitantly. Therefore, a semi-continuous culture was performed by repeated refill and draw. In this mode, approximately 1.5 liters of the culture broth was replaced per cycle when the decolorization ratio of molasses was near 80%. The molasses medium (1.0 liter per day) was treated and the peroxidase productiveity in the drawn culture broth was 26.6U/day, whereas the peroxidase productiveity was 17.9U/day in the continuous culture with a dilution rate of $0.005h^{-1}$. The semi-continuous treatment system was an efficient decolorization method for the strain, G. candidum Dec 1.

Colloidal Textile Dye-Based Dipstick Immunoassay for the Detection of Infectious Flacherie of Silkworm, Bombyx mori L.

  • Sivaprasad, V.;Nataraju, B.;Renu, S.;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 2003
  • Infectious flacherie of silkworm Bombyx mori is caused by B. mori infectious flacherie virus (BmIFV) and causes severe crop loss to sericulturists. In the present study, a colloidal textile dye-based dipstick immunoassay is developed for the detection of infectious flacherie in silkworms. Colloidal textile dye (blue D2R) with Aλ$_{max}$ at 620 nm was sensitised with 500 $\mu\textrm{g}$/ml of purified anti-BmIFV IgG. The dye-antibody reagent detects purified antigen up to 10 ng/ml and BmIFV infection in diseased larval extracts $(up to a dilution of {10^-5})$ and faecal matter extracts $(up to a dilution of {10^-2})$ by forming clear blue dot within 30 min. It was observed to be stable for three months period at $4^{\circ}C$. The efficacy of textile dye-based dipstick immunoassay was on pay with HRP-based dipstick immunoassay and fluorescent antibody test, and better than latex agglutination and ouchterlony tests in the detection of BmIFV The dye-based dipstick immunoassay method provides a simple, sensitive and less expensive test for the detection of BmIFV infection in silkworms.s.

Research & Development of High Performance & Multi-Functional New Grouting Materials for Ground Improvement & Reinforcement (고성능 다기능 특수 그라우트 신재료 개발 및 기초지반보강재로의 사례 연구)

  • Park, Bong-Geun;Cho, Kook-Hwan;Na, Kyung;Yoon, Tae-Gook;Lee, Yong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.338-350
    • /
    • 2010
  • As existing materials for ground reinforcement, chemical grout material using cementitous materials and waterglass was used. But many problems in terms of ground reinforcement effects were implicated. In this study, for development and applicability verification of new materials, viscosity, fluidity, permeability, Self-Leveling, keeping of drilled hole, antiwashout underwater, resistance of water (groundwater dilution and minimize material eluting) and the early strength and long-term strength characteristics of developed materials was confirmed, and material standards, and establishing construction standards for the various model tests were conducted. As a result, high viscosity, flowability, permeability and keeping of drilled hole characteristics are excellent, in addition to the early strength properties, dilution does nat occur to groundwater, including groundwater is available for dealing with environmental issues. Application of basic and reinforcement method by Filler function in addition to structure can also or development of a new concept can be expected. In addition, middle and large-diameter drilled shaft, micropile, ground anchors, soil-nailing, steel pipes multi-grouting reinforcement for cement injection process could be used enough to even be considered.

  • PDF

Effect of Cultivar and Processing on the Hemagglutinin Activity of Soybean

  • Felipe, Penelope;Sok, Dai-Eun;Heo, Ok-Soon;Kim, Hyoung-Chin;Yoon, Won-Kee;Kim, Hwan-Mook;Kim, Mee-Ree
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.91-95
    • /
    • 2006
  • Effects of cultivars, cooking, and processing on hemagglutinin activity were evaluated by observing macroscopic hemagglutination using serial twofold dilution of trypsinized human blood type-O or rabbit blood. Hemagglutinin activity was expressed as maximal geometric dilution fold. Agglutination of rabbit blood was more sensitive compared to human blood. Hemagglutinin activities of glyphosate-tolerant soybean, HS2906, and imported conventional soybeans were not statistically different, although significant differences were observed among conventional soybean cultivars cultivated in Korea (286 to 1535 HU/mg protein). Time required to reach fifty percent inhibition of hemagglutinin activity ($IT_{50}$) value decreased with increasing cooking temperature and pressure. Most effective conventional cooking method to inhibit hemagglutinin activity was pressure-cooking ($IT_{50}$: 1.36 min). Calculated activation energy based on reaction rate constant was 4.88 kcal. No hemagglutinin activities were detected in processed soybean products such as tofu, soybean paste, and soysauce.

A review on a 4 K cryogenic refrigeration system for quantum computing

  • Park, Jiho;Kim, Bokeum;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.2
    • /
    • pp.1-6
    • /
    • 2022
  • This paper reviews the literature that has been published since 1980s related to cryogenic refrigeration systems for quantum computing. The reason why such a temperature level of 10-20 mK is necessary for quantum computing is that the superconducting qubit is sensitive to even very small thermal disturbances. The entanglement of the qubits may not be sustained due to thermal fluctuations and mechanical vibrations beyond their thresholds. This phenomenon is referred to as decoherence, and it causes an computation error in operation. For the stable operation of the quantum computer, a low-vibration cryogenic refrigeration system is imperative as an enabling technology. Conventional dilution refrigerators (DR), so called 'wet' DR, are precooled by liquid helium, but a more convenient and economical precooling method can be achieved by using a mechanical refrigerator instead of liquid cryogen. These 'dry' DRs typically equip pulse-tube refrigerators (PTR) for precooling the DRs around 4 K because of its particular advantage of low vibration characteristic. In this review paper, we have focused on the development status of 4 K PTRs and further potential development issues will be also discussed. A quiet 4 K refrigerator not only serves as an indispensable precooler of DR but also immediately enhances the characteristics of low noise amplifiers (LNA) or other cryo-electronics of various type quantum computers.

Application of Micro-BLISA in Serodiagnosis of Fascioliasis in Cattle (간질증의 효소면역학적 진단)

  • Lee, Jae-Gu;Baek, Byeong-Geol;Lee, Sang-Bok
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.1
    • /
    • pp.95-101
    • /
    • 1985
  • Fascioliasis in cattle is one of the most common and very serious trematode diseases in Korea. In the present study, the enzyme linked immunosorbent assay (ELISA) was applied in the diagnosis of fascioliasis using antigen of Fasciela hepatica, perokidase of conjugate anti-cattle Is G and orthophenylenediamine as a substrate by micro-method technique of Volley et at. (1976b) and MacLaren (1978) with a slight modification. Results obtained from the present study are as follows. 1. In assay for optimal dilution of stock antigen, the antigen (protein contents; 0. Bmgymz) was diluted from 1150 to 1/600 with carbonate buffer (pH 9.6), and then absorbance values were measured with 1/100 diluted sera. The regression equations between the OD values of ELISA and dilution of antigen were log Y: -0.181-0.00127X in infected sera, and log Y: -0.578-0. 000879X in normal sera. The significantly higher (p<0.05) OD value was observed in the former. 2. In assay for optimal dilution of sera, the sera were diluted from 1125 to 1/400 with in PBSJ Tween 20 (pH 7.4), and absorbance values were measured with 1/200 diluted antigen. The regression equation between the OD values of ELISA and dilution of sera were log Y: -0.1540-0.0007238X in infected sera and log Y: -0.4834-0.00116X in normal sera. The former was higher than the latter (p<0.05). 3. In the 27 cases of negative intradermal test, OD values of the ELISA are $0.447{\pm}0.144$, the 95% confidence interval (Mean+2 H SD) of the values was 0.735, and there was no case over the values. Therefore, the sensitivity of the antigen to diagnose fascioliasis was 100% in the negative case. The OD value 0.7 which is designed as a criterion (detection level of positive one) is useful for the performance of the ELISA in fascioliasis. 4. According to the OD value of criterion in the regression equations, the optimal dilutions of stock antigen and serum were 1/250 and 1/100, respectively. 5. In the 58 cases of fascioliasis from which the adult could be found in the bile ducts, the OD value was $0.846{\pm}0.224$. The 75% (44 cattle) among them had higher value with compared to the criterion, and the 60% (20 cattle) of the cases of proliferative cholangitis of 33 cattle which had been infected previousely with Fasciola sp. is higher than the criterion. 6. Prevalence of fascioliasis was 43.4% in the application of the ELISA to 272 cattle which were reared in Jeonbug district.

  • PDF

Characteristics of Oxidation System for Superconductor Thin Film( II ) (초전도 박막 제작을 위한 산화 시스템의 특성( II ))

  • An, I.S.;Park, Y.P.;Lim, J.K.;Jang, K.U.;Lee, H.K.;Kim, G.Y.;Lee, J.U.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.264-267
    • /
    • 2002
  • An ozone condensation system is evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone is condensed by the adsorption method and its concentration is analyzed by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the concentration evaluation from dilution to highly condensed ozone. The highest ozone concentration condensed by the adsorption method is evaluated to be 97 mol%

  • PDF

Characteristics of Oxidation System for Superconductor Thin Film( I ) (초전도 박막 제작을 위한 산화 시스템의 특성( I ))

  • Lim, J.K.;Park, Y.P.;Yang, D.B.;Kim, J.H.;Lee, H.K.;Park, N.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.272-275
    • /
    • 2002
  • An ozone condensation system is evaluated in the viewpoint of an ozone supplier for oxide thin film growth. Ozone is condensed by the adsorption and distillation method. Then their concentrations are analyzed by three methods; ultraviolet absorption, thermal decomposition and Q-mass analyzing methods. Thermal decomposition method is found to be available to the concentration evaluation from dilution to highly condensed ozone. The highest ozone concentration condensed by the adsorption method is evaluated to be 96 mol%. The ozone is supplied for a sufficiently long time to grow oxide thin films.

  • PDF