Kim, Ung-Gyu;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
The Journal of Korean Academy of Prosthodontics
/
v.59
no.1
/
pp.116-125
/
2021
A three-dimensional (3D) intraoral scanner, which is one of the major developments in digital dentistry, is widely used in fixed prosthodontics. The application of intraoral scanner is now increasing in removable prosthodontics. Sclerotic change induced by scleroderma causes the limitation of mouth opening and multiple loss of the teeth. Conventional prosthodontic procedures are challenging for patients with this disease. This study showed a case of digital approach to the removable prosthodontic treatment of a patient who had the scleroderma and the consequent microstomia. At the provisional stage, the optical impression of patient's oral structures was digitally obtained. Using a 3D printer, the provisional dentures were fabricated. After extraction of hopeless tooth, the definitive digital impression was taken and the metal frameworks were fabricated, based on the data acquired from the impression. The definitive removable partial dentures were completed and delivered to the patient, who was satisfied with the prostheses.
Purpose This study is to phenomenologically discover key antecedents and outcomes of behavioral process of SNS users who have multiple SNS sub-accounts. Unlike previous studies that focused on user behavior in the context of a specific SNS platform, this study attempts to describe how and why individual manages their multiple sub-accounts across a variety of SNS platforms. Design/methodology/approach By applying the grounded theory methodology (GTM) to elucidate the unique behavior in SNS platforms, this study has conducted in-depth interview with 14 respondents who handle multiple accounts across the SNS platforms. As a results of analyzing the interview manuscripts, this study has extracted 47 concepts, 10 sub-categories and 6 main categories by conducting open coding, axis coding, and selective coding. Findings By analyzing interview data, this study has derived main categories such as account management, impression management, self-categorization, authority to determine the relationship, digital shadow work, and portfolio SNS accounts from qualitative interview data. This study has also conducted a process analysis that represents how main categories could be inter-related. Based on findings, this study provides a new phenomenological perspective to understand the behavioral process of SNS users' sub-account usage experience.
Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.
Journal of the Korean Academy of Esthetic Dentistry
/
v.22
no.1
/
pp.22-29
/
2013
In general, to conduct aesthetic restorations, various analyses are carried out using a camera from the initial examination with the final prosthesis in consideration. With the reality that many dentists are using digital cameras, it can be considered that the time of digital impression has already started. Just as the recent general trend is that more and more internationally renowned photographers are switching their film cameras to digital counterparts, it is likely that CAD/CAM will show another direction in the area of the aesthetic dentistry that we may want to pursue. With the word 'digital', the convenience and economics often come to mind in the first place. However, from the dental clinical viewpoint, it is important to improve and develop the CAD/CAM system based on understanding its specialty and superiority while respecting the conventional analog techniques. However, a regretful aspect is that it is often difficult to catch up with the latest advancements for proper referencing and follow-up of digital technologies since the CAD/CAM device and material are developing very rapidly. Accordingly, although it is ideal to have hands-on experiences in various digital material and devices, and adapt to their fast changes, it must be stressed that the clinical application is to be implemented on the basis of the proven traditional way of dental clinics in order to obtain better outcomes. This presentation will explore types of approaches that can be made by combining the traditional techniques and the CAD/CAM from the aesthetic viewpoint. In addition, it is hoped and eagerly awaited that the CAD/CAM restoration may play a significant role in the field of the 'digital art'.
PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).
Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
Journal of Korean Dental Science
/
v.15
no.1
/
pp.92-99
/
2022
This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.
International Journal of Internet, Broadcasting and Communication
/
v.15
no.4
/
pp.21-30
/
2023
The aim of this study is to investigate how travelers' destination visit intentions are influenced by avatar self-congruence in the metaverse platform. We extended the impression management theory by considering both perceived enjoyment and social engagement, and illustrated the interaction effect based on users' digital age. To achieve this, we conducted an online survey with 302 users. The survey results revealed that avatar self-congruence significantly influenced users in terms of perceived enjoyment and social engagement, thereby affecting their destination visit intentions. This study also revealed a significant interaction effect between digital age type and avatar self-congruence on users' perceived enjoyment. The results of this study are expected to provide not only a theoretical reference for metaverse research and travel research but also managerial implications for destination management and metaverse applications.
Journal of the Economic Geographical Society of Korea
/
v.19
no.2
/
pp.189-208
/
2016
This research aims to discuss the impact of on regional development as a place brand and glocal heritage. Based on understanding of the changes and influences of local heritages in the globalization era as a key component of place branding, this study explores how is used to develop a place branding strategy for Lijiang. The research methods are both a literature review and a field research related to Lijiang and its culture. Also, the resources from news, internet, and YouTube are used to analyze the impact of . The performance has been attracting tourists from both Chineses and foreigners and contributed to increase the economic profits of local tourism industry as one of the representative identities of Lijiang. Also, in the process of preservation and recreation of cultural heritages of Lijiang such as , the participation of local residents and on-going interactions between the residents and global tourists highly influence on a transition from place marketing to place branding. By applying local cultural heritages to place branding strategies, the regional values of Lijiang strengthen its place identity from a place of preserving a minority's heritage to that of flourishing cultural exchanges and hybridization from the world.
Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.
Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.