• Title/Summary/Keyword: digital impression

Search Result 170, Processing Time 0.028 seconds

A case of removable dentures using digital method (디지털 방식을 이용하여 제작한 양악 가철성 의치 수복 증례)

  • Lee, Ji-Soo;Ahn, Su-Jin;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.250-257
    • /
    • 2018
  • Generally dentures are manufactured by conventional method, however the frequency of fabricating denture using digital method is increasing due to the recent development of digital technology in dentistry. The digital method of manufacturing denture is classified into two systems; 3D scan of the impression to arrange the artificial teeth on the CAD (Computer-aided design) and 3D printing to produce the resin-based complete denture, or 3D scan of the model to design of the framework using CAD, resin pattern formation by 3D printing and casting of metal framework of complete denture or removable partial denture. In this case report, electronic surveying and design the metal framework of the dentures were performed using CAD program, and plastic resin patterns fabricated by 3D printing were casted for upper full denture and lower removable partial denture. During follow-up periods, dentures using digital method have provided satisfactory results esthetically and functionally.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

A procedure for the computer-guided implant planning: A narrative review (임플란트 가이드 수술을 위한 Planning 방식에 대한 고찰)

  • Kim, Jong-Eun;Kim, Nam-Hoon;Park, Ji-Hyun;Shim, June-Sung
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.108-122
    • /
    • 2016
  • Prosthetic-driven implant placement is a concept considering the dental implant restoration first based on the final form of that prosthesis to be restored. The latest development of the imaging technology and digital dentistry was able to be obtained the high quality images of CBCT with low radiation exposure and it has also enabled the process to reconstruct the intraoral state in three dimensions due to the development of the intraoral, model and impression scanner. Computer-guided implant placement simulations and template production was able to be more widely used in this context. In this narrative review, the features and the types of implant surgical guides will be introduced. It will also be described the diagnosis and treatment plan using computerguided implant software to reduce the number of visit and to increase the accuracy of the implant surgery through the top-down approach based on the shape and location of the final prosthesis.

  • PDF

Exploring Teachers' Perceptions and Beliefs about the Acceptance of Smart Education and Preschoolers' Digital Literacy (교사들의 스마트 교육 수용과 유아 디지털 리터러시에 대한 인식 탐구)

  • Lee, Eun-Jeong;Lee, Jae-Shin
    • Informatization Policy
    • /
    • v.23 no.3
    • /
    • pp.64-83
    • /
    • 2016
  • Although the government mandated classroom use of smart technology, there exist obstacles to adapting smart technology as a means of educational tools in class. This study aims to explore the preconditions for integrating smart technology and early childhood education. To meet this end, this study investigates preschool teachers' perceptions about the possible benefits or negative impacts of using smart media on child education. Results show that teachers have negative rather than positive perceptions and attitudes toward preschoolers' use of smart media, which implies that rendering teachers have positive impression on smart education is most important for fostering smart education.

A Study on Positive User Experience Design for Customer to Participate as a Unexpectedness (적극적인 고객 참여를 위한 사용자 경험으로서 의외성에 관한 연구)

  • Lee, Kyu Tae;Kim, Sung Hoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.4
    • /
    • pp.171-182
    • /
    • 2010
  • The precent, many outdoor advertisements in the media has such experience. Looking at the trend of outdoor advertising media, visual stimuli, causing extreme curiosity, stimulate emotion, expression, such as illogical to consumers using a variety of unexpectedness "surprising expression" attempt to give a strong impression on consumers appears to can. In this study, outdoor advertising media, outdoor advertising is now through the case study to evaluate the characteristics of the media in the unexpectedness, in the process based on components derived extraordinariness configure Tetrad Map and extraordinariness factors of outdoor advertising media Analysis of the key elements to configure the user experience factor that has the purpose of identifying the characteristics extraordinariness. As a result of analysis of outdoor advertising media element to configure the Visual / Installation / Technology / Story of the most important factors acting Visual elements were found to be leveraging. Components, as well as factors was higher than the interest factor involved. So now with the development of outdoor advertising media, the unexpectedness expression appears in the flow, limited to the visual aspect of extraordinariness factors that could be seen being used. Characteristics of outdoor advertising media in the past did not deviate more as consumers look to stimulate the technical attributes of a visual form that could be seen to be extended.

A Study on Characteristics of Male's Make-up (남성 메이크업의 특성 연구)

  • Kim, Hye-Kyun
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.635-640
    • /
    • 2012
  • A changed image that they feel through makeup manipulates impression by linking with cultural standards and will be able to direct a variety of makeup images. Makeup in modern society has been expanding into the area of prevention of diseases and health of skin due to the development of cosmetics and has beautifully changed a face into a someone else's face due to the development of makeup technique. Also, assuming that motivation of makeup act of men and women is related to sexual instincts, I tried to analyze what kind of association the gender roles and the function of makeup required by the society has with age and regional and social background. In particular, I tried to explain that makeup act of men not only represents cognitive change of gender roles that have been perceived differently in modern society but has been adopted by men for the pure purpose in a socially equitable competition.

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.