Designed OTP Generation Method Using Health Information (건강정보를 이용한 OTP 생성 방식 설계)

  • Choo, Yeun-Su;Kang, Jung-Ho;Kim, Kyoung-Hun;Park, Jea-Pyo;Jun, Moon-Seog
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.315-320
    • /
    • 2015
  • User Authentication in Online service is essential for accurate and safe service. For this user authentication, One Time Password(OTP) is frequently used. To satisfy one-time-use characteristic of OTP, Offset information to generate OTP or final OTP value get generated through OTP generator or security card which could be lost. In this study, OTP generation method that bypasses OTP generator or security card by using health information collected from u-Health care system is proposed. Suggestion is that health information collected through wearable devices get utilized to offset information that are applied in OTP generations. OTP generated using suggested methods showed similar results than current OTP generation methods in the collision resistance test which tests how often it generate same authentication numbers, this implies that new proposed method can be applied to various on-line services.

The Influence of Health Apps Efficacy, Satisfaction and Continued Use Intention on Wearable Device Adoption: A Convergence Perspective (헬스 앱의 효능감과 만족도, 지속적 사용의도가 웨어러블 기기의 수용에 미치는 효과: 융복합적 관점)

  • Park, Dong-Jin;Choi, Joung-Hwa;Kim, Do-Jin
    • Journal of Digital Convergence
    • /
    • v.13 no.7
    • /
    • pp.137-145
    • /
    • 2015
  • Mobile's health care and diagnostic capabilities are accepted as the most innovative sectors, and the combination with wearable device is being predicted as the future's most promising industries. However, the level of consumer acceptance and utilization is still insufficient compared to the development of technology. This study explores the use intention of wearable device based on previous studies about health apps. In particular, health-related use efficacy of the app, app use intention and app satisfaction are analyzed through a structural equation model. The use of health-related apps revealed that there is a statistically significant relationship with the use of the wearable device. The results suggest that the importance of app use efficacy, satisfaction, apps use should be considered for the successful diffusion of wearable health devices.

Factors Influencing on Serious Dental Disease of Korea Elderly (노인의 중대 구강병 영향요인에 관한 연구)

  • Won, Young-Soon;Park, A-Reum
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.267-275
    • /
    • 2018
  • This study was conducted to analyze the impact factors of serious dental disease of elderly and to propose the need to treatments of negative factors on oral health-related quality of life. This study used the data of the 6th 3nd-year(2015) National Health and Nutrition Examination Survey. The dependent variables of this study were reviewed for serious dental diseases, and the independent variables were divided into demographic characteristics, health status and behavior, oral health status, and behavior. The results of study were as follow. Factors influencing dental caries was household income(p<.01), health checkups(p<.05), experience of toothache for the recent 1 year(p<.05), and whether to use oral hygiene devices(p<.05). Factors influencing periodontal disease was age(p<.05), occupation(p<.05), and whether to Comorbidity(p<.05). Based on these results, a political alternative plan will need to be arranged for promoting oral health in the aged as a relevant research is vitalized.

Current status of dental intraoral imaging devices and radiographic safety management (치과 구내촬영 장비 현황과 방사선 안전 관리 실태 연구)

  • Kang, Eun-Ju;Hyeong, Ju-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.205-214
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the current status and radiographic safety management in Korea. Methods: A self-reported questionnaire was completed by 200 dental hygienists in Jeonbuk province from September 1, 2014 and October 31, 2014. The questionnaire consisted of general characteristics of the subjects, radiation knowledge, radiation safety management, and radiation exposure anxiety. Data were analyzed using SPSS 18.0 program. Results: Duration of clinical experience(r=0.142) and number of daily radiation shot(r=0.145) showed a positive correlation to radiation safety management, and a nrgative correlation to use of intraoral films and digital devices(r=-0.587). A logistic regression analysis was performed in order to evaluate the influence on radiography knowledge. The results showed that the factors had significant influences on the age group over 41 years old(OR 7.25; 95% CI 1.30-40.43) and those who took a position above team leader(OR 0.23; 95% CI 0.59-0.90). Conclusions: It is very important to have the safety management toward dental intraoral imaging and radiograpgic shot in the dental hygienists. Continuous efforts should be emphasized on radiographic safety management and behavior.

Desing of VR Contents for Visual Function Enhancement (VR 기반 시기능 강화 콘텐츠 설계 및 제작)

  • Yong-Ju Kim;Sang-Joong Jung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.70-75
    • /
    • 2022
  • With the spread of various digital devices, devices have become commonplace in modern society. Moreover, due to the increase in device usage and online learning while staying indoors during the COVID-19 pandemic, symptoms such as an increase in myopia in children due to eye fatigue, an increase in young presbyopia, and dry eye syndrome are increasing, and now people are paying attention to eye health. This is different from before. There are various prescriptions for eye health, but in this paper, we would like to propose a training method for enhancing visual function using VR contents. The analog methods of the existing teaching aids for visual function reinforcement training were planned and produced as digital contents, and VR-based training contents were selected from among the various methods carried out with teaching aids at the visual function training center, which can be made into contents. was developed with In the training process for each content, it was proposed to apply eye tracking to the VR device in order to give the user feedback on their participation in the training so that the management and concentration of the training process could be analyzed.

The Design and Implement a Healthcare Alert App to Prevent Dementia (치매예방을 위한 헬스케어 알리미 앱 설계 및 구현)

  • Pi, SU-Young
    • Journal of Digital Convergence
    • /
    • v.16 no.10
    • /
    • pp.59-67
    • /
    • 2018
  • There are not that many m-health related services limited to the elderly. Many of the elderly who are at risk of dementia are unfamiliar to smart devices, so it is required to design an user-customized App. Therefore, I design and embody a mobile voice alert integrated app, which enables voice input to increase the accessibility of the elderly, so as to prevent diseases caused by declined cognitive function such as dementia. I conducted interviews and questionnaire after having the students use the app in Lifelong Education Center in H region of Gyeongbuk, and the analysis result has showed the high satisfaction. It is expected that it will be able to play a key role for M-Health service for the elderly since it is possible to prevent dementia through the voice health care alert app. I would like to learn deep learning in the future to predict the life patterns and the possibility of dementia of the elderly.

Pollution Research about Radiology radiographic laboratory (방사선 영상학 실습실 오염실태 조사 (D대학교 DR장비와 방사선 발생장치, Cassette 오염실태 조사))

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.69-76
    • /
    • 2013
  • We checked the existence of bacteria at DR equipment, radiation generator and cassette in 'D university' to propose optimized management method for bacteria and disinfection at DR equipment, radiation generator and cassette at used in radiographic laboratory of the department of radiology. The infected region is treated by alcohol and cresol and compared before spraying and after spraying for 1, 3, 5 and 10 minutes. As time goes on, amount of bacteria colony decreases significantly. The Cresol is useful to disinfect the diminutive devices. However alcohol disinfection, at least 5 minutes later, and hand washing before practical training and shooting image is recommended due to the big and fixed radiography equipment which cause the soakage.

  • PDF

Emergence of the Metaverse and Psychiatric Concerns in Children and Adolescents

  • Soyeon Kim;Eunjoo Kim
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.34 no.4
    • /
    • pp.215-221
    • /
    • 2023
  • Advancements in digital technology have led to increased usage of digital devices among teenagers. The coronavirus disease 2019 pandemic and the subsequent implementation of social distancing policies have further accelerated this change. Consequently, a new concept called the metaverse has emerged. The metaverse is a combination of a virtual reality universe that allows individuals to meet, socialize, work, play, entertain, and create. This review provides an overview of the concept and main features of the metaverse and examples of its utilization in the real world. It also explains the unique developmental characteristics of childhood and adolescence, as well as the possible negative influences of the metaverse on them, including addiction, antisocial behavior, cyberbullying, and identity confusion. This review summarizes several suggestions for future research because the metaverse is a relatively new concept.

Development of HL7 V 2.5 Middleware for Patient Monitoring Device (환자감시장치를 위한 HL7 V2.5 미들웨어의 개발)

  • Kim, Hyung-Hoi;Cho, Hune;Tran, Tung;Hong, Hae-Sook;Kim, Hwa-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1680-1687
    • /
    • 2007
  • A hospital room has multiple patient monitoring devices at the bedside to monitor his or her status. However, vital sign monitors, ventilator and other bedside devices are made by a variety of different manufacturers and often cannot easily interface to the hospital information system. Medical environments incorporate complex and integrated data networks to transfer vast amounts of patient information, such as images, waveforms, and other forms of digital data. Hence, to assure interoperability of images, waveforms and patient data, Health Level Seven (HL7) was developed as an international standard to facilitate the communicating and storing of medical data. In this study, we developed middleware capable of receiving data from mCare 300 vital signs monitoring devices and converting the data to HL7 data format. The HL 7 middleware streamline clinical workflow and support patients. Therefore, clinical expertise are empowered to respond to dynamic healthcare situation as soon as they emerged, and consequently quality of care while helping to reduce the length of a patient's stay in a hospital.

Implementation of a Portable Breathalyzer Using MEMS Sensor (MEMS 센서를 활용한 휴대용 음주 측정기 구현)

  • Ju, Yong-Wan;Park, Jang-Sik;Kim, Hyun-Tae;Yu, Yun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.779-781
    • /
    • 2011
  • Drinking is one of most prominent causes for social problems like domestic violence, drinking and driving, and health problems. If who drunken can check promptly how much blood alcohol content, abstain from drunken driving or successive drinking schedule. In this paper, implementation of digital portable breathalyzer using semiconductor gas sensor based on MEMS were suggested. A small size micro controller with low power and surface mountable, ATMEGA48 can control semiconductor gas sensor digitally and display the value of alcohol concentration on LED.