• Title/Summary/Keyword: digital calibration

Search Result 379, Processing Time 0.028 seconds

The Error Analysis of the Rain-Gauges typed of Tipping Bucket according to Rainfall Intensity (강우강도에 따른 전도형 우량계의 오차특성 분석)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2507-2509
    • /
    • 2005
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study. Also, we calculated the error for the rainfall intensity and obtained useful result through the proposed calibration method.

  • PDF

Development of Kinematic Calibration System for a Parallel-typed Machining Center Tool (병렬기구형 공작기계의 보정 시스템 개발)

  • Kim, Tae-Sung;Park, Kun-Woo;Yoon, Tae-Sung;Lee, Min-Ki
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.521-526
    • /
    • 2001
  • This research develops a low-cost and high accurate kinematic calibration method for a parallel typed machining center tool. A planar table is used for a mechanical fixture restricting the platform to place at the constrained pose and a low-cost and high accurate digital indicator is employed for a device checking if the constrained movement is satisfied within the established range. The kinematic parameters calibrated with respect to a single plane aren't influenced from the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that the kinematic parameters is estimated by minimizing the cost function.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Radiometric Characteristics of KOMPSAT EOC Data Assessed by Simulating the Sensor Received Radiance

  • Kim, Jeong-Hyun;Lee, Kyu-Sung;Kim, Du-Ra
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.5
    • /
    • pp.281-289
    • /
    • 2002
  • Although EOC data have been frequently used in several applications since the launch of the KOMPSAT-1 satellite in 1999, its radiometric characteristics are not clear due to the inherent limitations of the on-board calibration system. The radiometric characteristics of remotely sensed imagery can be measured by the sensitivity of radiant flux coming from various surface features on the earth. The objective of this study is to analyze the radiometric characteristics of EOC data by simulating the sensor- received radiance. Initially, spectral reflectance values of reference targets were measured on the ground by using a portable spectre-radiometer at the EOC spectrum. A radiative transfer model, LOWTRAN, then simulated the sensor-received radiance values of the same reference target. By correlating the digital number (DN) extracted from the EOC image to the corresponding radiance values simulated from LOWTRAN, we could find the radiometric calibration coefficients for EOC image. The radiometric gain coefficients of EOC are very similar to those of other panchromatic optical sensors.

A Study on the Accuracy Improvement of Control Point Surveying of Photograph Using Digital Camera (디지털 카메라를 이용한 사진기준점측량의 정확도 향상에 관한 연구)

  • Kim, Kye-Dong;Park, Joung-Hyun;Lee, Young-Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.203-211
    • /
    • 2009
  • With supply of the domestic digital camera, the relative importance of the digital camera is coming to be high gradually on aerial photogrammetry, the image of digital camera is more applied in image map or digital topographic map production. But, there are cases that do not have position information or attitude information of each photograph in digital camera results. Therefore, we wish to present additional method to get more accurate photograph control point result. In this study, One is called A method, which is the case of entering positioning information of principal point from topographic map as default values that are need to extract tie point automatically using by 56 pieces of photography that are photographed by DMC to the extent to 5 courses and 35 GCP points. The other is called B-method, which is the case of entering exterior orientation parameters that are processed by block adjustment for A-method using by 4 control points in method-1 as default values. We have analyzed about results per control points arrangement for two cases using MATCH-AT that is photograph control point measurement S/W of Germany INPHO company. As a result of analysis, accuracy of B-method was better than that of A-method, and we could get more accurate results if block adjustments are executed including self calibration. Also, it is more effective in expense side that using self calibration for photograph survey in B-method because can reduce GCP numbers.

Development of Projector Calibration Mapping Technology for Physically Interactive Sport Game (체감형 스포츠 게임을 위한 프로젝터 캘리브레이션 매핑 기술 개발)

  • Gil, Young-Ik;Seo, Hye-Ran;Lee, Hyeon-Ju;Ko, Il-Ju
    • Journal of Korea Game Society
    • /
    • v.19 no.5
    • /
    • pp.39-52
    • /
    • 2019
  • Recently many studies has been conducted for interactive game to contents immersion through visual stimuli. Among them, Multi-Plane Image tech is suitable for projecting video in wide views, but it is difficult to perform calibration and mapping tasks for viewing separately. In this paper, we developed a calibration mapping applies to the field archery game space in the form of CAVE. As a result, we maintained the resolution confirmed the space through the video without distortion and expect to be applicable to the fields requiring presence, such as training contents.

Comparison of Sphygmomanometer, Fully Automatic Electronic Blood Pressure Meters with Standard Digital Blood Pressure Monitor : Pilot Study (표준전자식 혈압계와 수은혈압계, 전자혈압계의 비교 선행연구)

  • Yahng, J.S.;Lim, H.K.;Cho, D.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.155-162
    • /
    • 2012
  • Devices to measure the blood pressure of patients are being used without any calibration in a hospital. It is an important to show consistent values when any medical devices measure the same patients regardless they are sphygmomanometer or fully automatic electronic blood pressure meter. We compared sphygmomanometer and fully automatic electronic blood pressure meters with standard digital blood pressure monitor (SDBPM) to evaluate the consistency of the small healthy subjects. We measured the blood pressure from six healthy subjects (three of 20~40 years and three of 40~60 years old). Two sphygmomanometer and two fully automatic electronic blood pressure meters were used and compared with the SDBPM. Blood pressures measured from right and left arms each and were compared. All six healthy subjects showed normal blood pressure values. In general, left blood pressure values showed higher values than right side. Comparing SDBPM, with the other monitors, the systolic pressure showed ${\pm}$ 34.8% difference and ${\pm}$ 33.3% for the diastolic pressure. Correlation between SDBPM and Sphygmomanometer was 0.59~0.71, and 0.50~0.70 for fully automated digital BP monitors. It fell in grade-D when we apply the BHS(British hypertension society). AAMI(American association for the advancement of medical instrumentation) also showed unsatisfactory results for the mean value (${\leq}$ 5 mmHg) and standard deviation (${\leq}$ 8 mmHg). We tested sphygmomanometer and fully automatic electronic blood pressure meters and compared with a standard digital blood pressure monitor. All devices showed inconsistent blood pressures. A reliable calibration system is highly needed for all devices in all hospitals.

Near-Field Rx-Measurement for Active Phased Array of Digital Radar Using Calibration Path (보정 경로를 활용한 디지털 레이더의 능동 위상 배열 근접전계 수신시험)

  • Yu, Je-Woo;Chae, Heeduck;Park, Jongkuk;Lim, Jae-Hwan;Kim, Duckhwan;Jin, Hyoung-Seog;Kim, Han-Saeng
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.504-511
    • /
    • 2016
  • In this paper, the method is proposed that the equivalent result can be obtained by compensating the variation of gain and phase in the comparison with the result of near-field measurement which is obtained in the steady state, although the gain and phase variation of rx-channels occurred in the near-field rx-measurement of digital active phased array antenna. The proposed concept has the time section for monitoring the state of the rx-channels through the calibration path in the measurement timeline, and is the method for compensating the variation of state. For validating the proposed method, the fabricated X-band digital active phased array antenna and the planar near-field measurement facility is utilized. The proposed method is validated in the comparison with the compensated pattern which the unstable state of rx-channels is calibrated and the reference pattern obtained under the steady state of the rx-channels.

A case study on calibration of computational model for a reasonable cost estimation of missile development program (A case of guidance & control system of X missile) (유도무기 연구개발사업의 합리적인 비용 추정을 위한 전산모델 보정방안 사례 연구 (X 유도무기 유도조종장치 사례를 중심으로))

  • Park, Chung-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.5
    • /
    • pp.139-148
    • /
    • 2014
  • In recent years, computational models using parametric estimation method have been developed and used widely for efficient cost analysis. In this research, by applying experienced data from Guidance and Control Systems in Missile System field, the cost analysis for engineering model and commercial computational model(Price H, HL, M, S) are conducted and its result is analysed, so that the difference between two models and its grounds are apprehended. Comparing the calibrated value of computational model based on the data base of similar equipment and the cost from the engineering estimation, the two results are very close. It means that the credibility of data is enhanced through calibration. Also, for cost analysis of similar components in the future, the method for calibration of the computational models is also examined. When estimating development cost in this research, although many parts have been estimated through uncertain elements, the reliability could have been enhanced by applying computational model which secures objectivity. It is a very reasonable estimation method by utilizing calibration of the computational models based on existing accumulated development data.

Estimation of the Hapcheon Dam Inflow Using HSPF Model (HSPF 모형을 이용한 합천댐 유입량 추정)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.69-77
    • /
    • 2019
  • The objective of this study was to calibrate and validate the HSPF (Hydrological Simulation Program-Fortran) model for estimating the runoff of the Hapcheon dam watershed. Spatial data, such as watershed, stream, land use, and a digital elevation map, were used as input data for the HSPF model. Observed runoff data from 2000 to 2016 in study watershed were used for calibration and validation. Hydrologic parameters for runoff calibration were selected based on the user's manual and references, and trial and error method was used for parameter calibration. The $R^2$, RMSE (root-mean-square error), RMAE (relative mean absolute error), and NSE (Nash-Sutcliffe efficiency coefficient) were used to evaluate the model's performance. Calibration and validation results showed that annual mean runoff was within ${\pm}4%$ error. The model performance criteria for calibration and validation showed that $R^2$ was in the rang of 0.78 to 0.83, RMSE was 2.55 to 2.76 mm/day, RMAE was 0.46 to 0.48 mm/day, and NSE was 0.81 to 0.82 for daily runoff. The amount of inflow to Hapcheon Dam was calculated from the calibrated HSPF model and the result was compared with observed inflow, which was -0.9% error. As a result of analyzing the relation between inflow and storage capacity, it was found that as the inflow increases, the storage increases, and when the inflow decreases, the storage also decreases. As a result of correlation between inflow and storage, $R^2$ of the measured inflow and storage was 0.67, and the simulated inflow and storage was 0.61.