• Title/Summary/Keyword: digital CDS

Search Result 22, Processing Time 0.026 seconds

In-plane Stress Analysis of Rotating Composite Disks (복합재료 회전원판의 면내응력 해석)

  • Koo, Kyo-Nam
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.176-179
    • /
    • 2005
  • Rotating annular disks are widely used in data storage devices such as CDs, DVDs(digital versatile disks), and HDs(hard disks) as well as in traditional industrial machines like sawing machines, turbines, brake disks. The exact stress distribution of rotating polar orthotropic disk is derived by solving directly the equilibrium equation instead of using stress function. Stress distributions for typical GFRP and CFRP disks are presented in addition to polycarbonate disk. The results show that the application of CFRP to rotating disk can increase the maximum allowable rotating speed but this may not be applicable to GFRP disk.

  • PDF

Vibration Analysis and Critical Speeds of Rotating Polar Orthotropic Disks, Part I : Formulation and Solution Method (극직교 이방성 회전원판의 진동해석 및 임계속도 I : 정식화 및 해법)

  • Koo, Kyo-Nam
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.169-175
    • /
    • 2006
  • Rotating annular disks are widely used in data storage devices such as CDs, DVDs(digital versatile disks), and HDs(hard disks). Higher data transfer rate in data storage disks could not be achieved by polycarbonate disks in the present market. The problem can be solved by applying the fiber-reinforce composite materials to the disks. In this paper, an application of composite materials to rotating disks is proposed to increase the critical speed. Dynamic equation is formulated in order to calculate the natural frequency and critical speed for rotating composite disks by the Galerkin method. The orthogonal functions are used in series solution. A companion paper(Part II) presents and discusses the numerical results of vibration analysis and critical speed for rotating polar orthotropic disk using the formulation and solution method given in this paper (Part I).

Vibration Analysis and Critical Speeds of Rotating Polar Orthoropic Disks (극직교 이방성 회전원판의 진동특성 및 임계속도)

  • Koo, Kyo-Nam;Han, Jae-Heung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.337-340
    • /
    • 2005
  • Rotating annular disks are widely used in data storage devices such as CDs, DVDs(digital versatile disks), and HDs(hard disks). Higher data transfer rate in data storage disks could not be achieved by polycarbonate disks in the present market. The problem can be solved by applying the fiber-reinforce composite materials to the disks. In this paper, an application of composite materials to rotating disks is proposed to increase the critical speed. Dynamic equation is formulated in order to calculate the natural frequency and critical speed for rotating composite by the Galerkin method. The results show that the radially reinforced disk is more effective in increasing critical speed than the circumferentially reinforced disk.

  • PDF

Low Power 31.6 pJ/step Successive Approximation Direct Capacitance-to-Digital Converter (저전력 31.6 pJ/step 축차 근사형 용량-디지털 직접 변환 IC)

  • Ko, Youngwoon;Kim, Hyungsup;Moon, Youngjin;Lee, Byuncheol;Ko, Hyoungho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.93-98
    • /
    • 2018
  • In this paper, an energy-efficient 11.49-bit successive approximation register (SAR) capacitance-to-digital converter (CDC) for capacitive sensors with a figure of merit (FoM) of 31.6 pJ/conversion-step is presented. The CDC employs a SAR algorithm to obtain low power consumption and a simplified structure. The proposed circuit uses a capacitive sensing amplifier (CSA) and a dynamic latch comparator to achieve parasitic capacitance-insensitive operation. The CSA adopts a correlated double sampling (CDS) technique to reduce flicker (1/f) noise to achieve low-noise characteristics. The SAR algorithm is implemented in dual operating mode, using an 8-bit coarse programmable capacitor array in the capacitance-domain and an 8-bit R-2R digital-to-analog converter (DAC) in the charge-domain. The proposed CDC achieves a wide input capacitance range of 29.4 pF and a high resolution of 0.449 fF. The CDC is fabricated in a $0.18-{\mu}m$ 1P6M complementary metal-oxide-semiconductor (CMOS) process with an active area of 0.55 mm2. The total power consumption of the CDC is $86.4{\mu}W$ with a 1.8-V supply. The SAR CDC achieves a measured 11.49-bit resolution within a conversion time of 1.025 ms and an energy-efficiency FoM of 31.6 pJ/step.

Dimming Control of A Automotive HID Lamp Ballast Using Digital Control Method (디지털제어방식을 이용한 자동차용 고압방전등 안정기의 조광제어)

  • Lee, Jae-Hak;Kim, Yoon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.24-33
    • /
    • 2005
  • This paper presents dimming control system for automotive 35[W] metal halide discharge(MHD) lamp electronic ballast using digital control method. HID system has been becoming increasingly popular due to its superior performance(high luminous efficacy, good color rendering and long life etc.)over the conventional halogen system. However, this lamp demands a highly efficient ballast and very complex control circuitry that can control complex transient state in applying to automotive. Therefore, in this paper, digital control method for the HID lamp ballast is presented for optimal control that can adapt complex transient state, steady state and various environments. In developed dimming system, the system is designed to control the lamp output voltage step by step using microcontroller according to cds sensor. Therefore the designed dimming control system give good driving condition to diver and realize the power control effectively. The results of the proposed system is verified through various simulation results and the experiment results.

A CMOS active pixel sensor with embedded electronic shutter and A/D converter (전자식 셔터와 A/D 변환기가 내장된 CMOS 능동 픽셀 센서)

  • Yoon, Hyung-June;Park, Jae-Hyoun;Seo, Sang-Ho;Lee, Sung-Ho;Do, Mi-Young;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.272-277
    • /
    • 2005
  • A CMOS active pixel sensor has been designed and fabricated using standard 2-poly and 4-metal $0.35{\mu}m$ CMOS processing technology. The CMOS active pixel sensor has been made up of a unit pixel having a highly sensitive PMOSFET photo-detector and electronic shutters that can control the light exposure time to the PMOSFET photo-detector, correlated-double sampling (CDS) circuits, and an 8-bit two-step flash analog to digital converter (ADC) for digital output. This sensor can obtain a stable photo signal in a wide range of light intensity. It can be realized with a special function of an electronic shutter which controls the light exposure-time in the pixel. Moreover, this sensor had obtained the digital output using an embedded ADC for the system integration. The designed and fabricated image sensor has been implemented as a $128{\times}128$ pixel array. The area of the unit pixel is $7.60{\mu}m{\times}7.85{\mu}m$ and its fill factor is about 35 %.

Does Internet Increase the Market Efficiency? (인터넷이 시장의 효율성을 증가시키는가?)

  • Lee, Ho-Geun;Lee, Ran-Hui
    • Information Systems Review
    • /
    • v.3 no.1
    • /
    • pp.3-18
    • /
    • 2001
  • The Internet is taking up every single life of us with a huge speed of growth. If the ideal market called 'perfect competition' in economics will ever come true in this digital world, the sellers won't be able to have monopolistic profits above the marginal cost any more, letting the resource allocation much more efficient. This paper attempts to test whether this theory is true in e-market as well through observing price differences between online and offline retailers of extremely homogeneous products, CDs. Since most results from previous research were supporting the inefficiency of e-market in price level, price adjustment, and especially price dispersion, this article designed the research methodology most carefully. The results of pervious works are partly due to the immaturity of the Internet market or due to the uniqueness of the American CD market, where oligopolistic market players are significantly dominant. The analysis of price data of 20 titles from 20 retailers for five weeks supports that online market is more efficient than offline market with statistical significance in all the three dimensions. We could conclude that the e-market is going much more efficient at least compared to the offline market and the more would it be unless the sellers resist and prevent comparison-shopping.

  • PDF

Usefulness of FTP Module on OCS for PACS Registration of External Medical Images (외부의료영상의 PACS 등록 시 OCS상 FTP Module의 유용성)

  • Jung, Myung-Jin;Dong, Kyung-Rae;Ji, Yeon-Sang;Choi, Jung-Gil;Jeon, Jae-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • This study was conducted to improve performance flow of PACS registration and output of external medical images by developing or adding File Transfer Protocol(FTP) Module on Order Communication System(OCS) and to upgrade efficiency of performance. The numbers of requests for examination of external medical images from January 2004 to December 2007 were investigated and the numbers of cases of examinations and losses were done respectively from January to June, 2007 as a period before the improvement and from July to December, 2007 as a period after it. Satisfaction of persons inputting external medical images of CD was asked directly before and after the improvement. When the numbers of requests for examination of external medical images from 2004 to 2007 2004 were investigated, they were 12,783, 16,774, 21,613 and 27,487 cases in 2004, 2005, 2005 and 2007 respectively. For the numbers of the requests from January to December, 2007 it was the lowest in February by recording 1846 and it was 2800 in October. While the number of loss of external medical images was averagely 3.6 before using FTP Module on OCS, it reduced to 0 and satisfaction increased to 98% after it. By utilizing FTP Module on OSC for PACS registration of external medical images, the images were delivered simultaneously with occurrence of order, PACS registration of many patients was conducted together and CDs were returned to patients immediately after sending images from outpatient clinics or wards to remove possibility of losing them. In addition, because the module was established on OCS and data were sent associated with order, problems related with order were decreased. By eliminating movement distance it was turned out to be very effective in terms of time and space.

  • PDF

Capacitive Readout Circuit for Tri-axes Microaccelerometer with Sub-fF Offset Calibration

  • Ouh, Hyun Kyu;Choi, Jungryoul;Lee, Jungwoo;Han, Sangyun;Kim, Sungwook;Seo, Jindeok;Lim, Kyomuk;Seok, Changho;Lim, Seunghyun;Kim, Hyunho;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • This paper presents a capacitive readout circuit for tri-axes microaccelerometer with sub-fF offset calibration capability. A charge sensitive amplifier (CSA) with correlated double sampling (CDS) and digital to equivalent capacitance converter (DECC) is proposed. The DECC is implemented using 10-bit DAC, charge transfer switches, and a charge-storing capacitor. The DECC circuit can realize the equivalent capacitance of sub-fF range with a smaller area and higher accuracy than previous offset cancelling circuit using series-connected capacitor arrays. The readout circuit and MEMS sensing element are integrated in a single package. The supply voltage and the current consumption of analog blocks are 3.3 V and $230{\mu}A$, respectively. The sensitivities of tri-axes are measured to be 3.87 mg/LSB, 3.87 mg/LSB and 3.90 mg/LSB, respectively. The offset calibration which is controlled by 10-bit DECC has a resolution of 12.4 LSB per step with high linearity. The noise levels of tri-axes are $349{\mu}g$/${\sqrt}$Hz, $341{\mu}g$/${\sqrt}$Hz and $411{\mu}g$/${\sqrt}$Hz, respectively.

The incidence of unexpected delays in uploading outside radiologic images in the transfer of patients with major trauma

  • Woo, Si Jun;Kim, Yong Oh;Kim, Hyung Il
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.92-98
    • /
    • 2022
  • Purpose: Critically ill patients are frequently transferred from one point of care to a hospital that can provide a higher level of care. To achieve optimal treatment within the targeted window of time necessary for time-sensitive cases like major trauma, rapid transportation and decision making are essential. Transferred patients have often undergone radiologic imaging at the referring hospital. Examining these outside images is paramount. Therefore, this study was conducted to estimate the upload time of outside images. Methods: This retrospective study was conducted from January to April 2020. Patients transferred from other hospitals with digitally recorded CDs or DVDs of radiologic or diagnostic images were included. When the patients were registered at the emergency department reception desk, the digital images were transmitted to our picture archiving and communication system using transmission software. The time of upload and the numbers of digital images were recorded. The time interval from patient registration to the time of upload was calculated. Results: The median number of images was 688 in the trauma team activation (TTA) group (688 in the TTA group, 281 in the non-TTA trauma group, and 176 in the nontrauma group, respectively; P<0.001). The median upload time was 10 minutes. The longest upload time was 169 minutes. The upload time was more than 20 minutes in 12 cases (19.4%). Conclusions: Patients with major trauma bring more images than patients with other diseases. Unexpected delays (>20 minutes) were noted in approximately 20% of cases. It is necessary to minimize this time.