• Title/Summary/Keyword: difference edge

Search Result 697, Processing Time 0.029 seconds

L(4, 3, 2, 1)-PATH COLORING OF CERTAIN CLASSES OF GRAPHS

  • DHANYASHREE;K.N. MEERA
    • Journal of applied mathematics & informatics
    • /
    • 제41권3호
    • /
    • pp.511-524
    • /
    • 2023
  • An L(p1, p2, p3, . . . , pm)-labeling of a graph G is an assignment of non-negative integers, called as labels, to the vertices such that the vertices at distance i should have at least pi as their label difference. If p1 = 4, p2 = 3, p3 = 2, p4 = 1, then it is called a L(4, 3, 2, 1)-labeling which is widely studied in the literature. A L(4, 3, 2, 1)-path coloring of graphs, is a labeling g : V (G) → Z+ such that there exists at least one path P between every pair of vertices in which the labeling restricted to this path is a L(4, 3, 2, 1)-labeling. This concept was defined and results for some simple graphs were obtained by the same authors in an earlier article. In this article, we study the concept of L(4, 3, 2, 1)-path coloring for complete bipartite graphs, 2-edge connected split graph, Cartesian product and join of two graphs and prove an existence theorem for the same.

막구조 정착부의 볼트접합부 막재료의 신장 및 파단상태를 통한 응력전달체계에 관한 연구 (Study on stress transition mechanism by tensile and fracture characteristics of membrane material at bolting part in clamping part of membrane Structures)

  • 김희균;심천보;김재열
    • 한국공간구조학회논문집
    • /
    • 제23권4호
    • /
    • pp.97-105
    • /
    • 2023
  • The membrane structure should maintain the membrane materials in tension for structural stability guaranty. The anchoring part in the membrane structure is an important part. It has the function to introduce tension into membrane materials and function to transmit stress which membrane materials receives to boundary structure such as steel frames. In this paper, it grasps anchoring system of the anchoring part in the membrane structure concerning the fracturing characteristic condition of membrane structure, and the influence which is caused to yield it designates the stress state when breaking the membrane structure which includes the anchoring part and that stress transition mechanism is elucidated as purpose. This paper follows to previous paper, does 1 axial tensile test concerning the bolting part specimen, grasp of fracturing progress of the bolting part and the edge rope and hardness of the rubber, does the appraisal in addition with the difference of bolt tightening torque. As a result, the influence which the bolt anchoring exerts on the fracturing characteristics of the membrane material in the membrane structure anchoring part is examined.

Treatment of Hip Microinstability with Arthroscopic Capsular Plication: A Retrospective Case Series

  • Tatiana Charles;Marc Jayankura;Frederic Laude
    • Hip & pelvis
    • /
    • 제35권1호
    • /
    • pp.15-23
    • /
    • 2023
  • Purpose: Hip microinstability is defined as hip pain with a snapping and/or blocking sensation accompanied by fine anatomical anomalies. Arthroscopic capsular plication has been proposed as a treatment modality for patients without major anatomic anomalies and after failure of properly administered conservative treatment. The purpose of this study was to determine the efficacy of this procedure and to evaluate potential predictors of poor outcome. Materials and Methods: A review of 26 capsular plications in 25 patients was conducted. The mean postoperative follow-up period for the remaining patients was 29 months. Analysis of data included demographic, radiological, and interventional data. Calculation of pre- and postoperative WOMAC (Western Ontario and McMaster Universities Osteoarthritis) index was performed. Pre- and postoperative sports activities and satisfaction were also documented. A P<0.05 was considered significant. Results: No major complications were identified in this series. The mean pre- and postoperative WOMAC scores were 62.6 and 24.2, respectively. The WOMAC index showed statistically significant postoperative improvement (P=0.0009). The mean satisfaction rate was 7.7/10. Four patients with persistent pain underwent a periacetabular osteotomy. A lateral center edge angle ≤21° was detected in all hips at presentation. We were not able to demonstrate any difference in postoperative evolution with regard to the presence of hip dysplasia (P>0.05), probably because the sample size was too small. Conclusion: Capsular plication can result in significant clinical and functional improvement in carefully selected cases of hip microinstability.

공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교 (Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos)

  • 장봉기;탁현욱;송수진;조봉현;김영지;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

층류박리 후향계단 유동의 이중주파수 가진 (Double Frequency Forcing of the Laminar Separated Flow over a Backward-Facing Step)

  • 김성욱;최해천;유정열
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1023-1032
    • /
    • 2003
  • The effect of local forcing on the separated flow over a backward-facing step is investigated through hot-wire measurements and flow visualization with multi-smoke wires. The boundary layer upstream of the separation point is laminar and the Reynolds number based on the free stream velocity and the step height is 13800. The local forcing is given from a slit located at the step edge and the forcing signal is always defined when the wind tunnel is in operation. In case of single frequency forcing, the streamwise velocity and the reattachment length are measured under forcing with various forcing frequencies. For the range of 0.010〈S $t_{\theta}$〈0.013, the forcing frequency component of the streamwise velocity fluctuation grows exponentially and is saturated at x/h = 0.75 , while its subharmonic component grows following the fundamental and is saturated at x/h = 2.0. However, the saturated value of the subharmonic is much lower than that of the fundamental. It is observed that the vortex formation is inhibited by the forcing at S $t_{\theta}$ = 0.019 . For double frequency forcing, natural instability frequency is adopted as a fundamental frequency and its subharmonic is superposed on it. The fundamental frequency component of the streamwise velocity grows exponentially and is saturated at 0.5 < x/h < 0.75, while its subharmonic component grows following the fundamental and is saturated at x/h= 1.5 . Furthermore, the saturated value of the subharmonic component is much higher than that for the single frequency forcing and is nearly the same or higher than that of the fundamental. It is observed that the subharmonic component does not grow for the narrow range of the initial phase difference. This means that there is a range of the initial phase difference where the vortex parring cannot be enhanced or amplified by double frequency forcing. In addition, this effect of the initial phase difference on the development of the shear layer and the distribution of the reattachment length shows a similar trend. From these observations, it can be inferred that the development of the shear layer and the reattachment length are closely related to the vortex paring.

얼음디스펜서와 홈바가 있는 빌트인 양문형 냉장고의 구조해석 및 도어 단차와 개스킷 간극의 평가 (Structural Analysis of Built-in Side-by-Side Refrigerator with Ice Dispenser and Home Bar and Evaluation of Door Differences and Gasket Gap)

  • 류시웅;이부윤
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.465-473
    • /
    • 2018
  • 냉동실 도어에 얼음디스펜서와 냉장실 도어에 홈바가 장착된 빌트인 양문형 냉장고 모델에 대하여 유한요소해석 프로그램인 ANSYS를 사용하여 캐비닛과 도어를 통합한 유한요소모델을 구성하고 변형해석을 수행하였다. 하중으로는 냉장고가 조립된 조건, 그리고 캐비닛 선반과 도어 배스킷에 적재되는 식품 부하물 하중과 냉장고 정상 작동 시의 온도분포에 의한 열하중조건을 고려하였다. 캐비닛과 도어의 변형량 해석결과에 기반하여 냉동실 도어와 냉장실 도어 사이의 상하단차와 앞뒤단차를 평가하고, 냉기 밀봉에 영향을 미치는 캐비닛 전면과 도어 내면 사이에 위치한 도어 개스킷의 간극의 증가량을 평가하였다. 부하물이 없고 냉장고가 작동하지 않는 조건의 해석결과 계산된 상하단차와 앞뒤단차는 제품 출하 시의 허용기준을 만족하는 것으로 나타났다. 부하물이 투입되고 냉장고가 정상 작동하는 열하중조건의 해석결과 계산된 상하단차와 앞뒤단차는 조립조건에 비해 증가하며 특히 앞뒤단차가 크게 증가시키는 것으로 나타났다. 열하중조건의 해석결과 계산된 캐비닛 전면과 도어 내면의 변위로부터 도어의 사각 테두리에 부착되는 개스킷 간극의 증가량을 평가하였다. 최대 간극 증가량은 냉동실 도어의 좌측 테두리에서 발생하며 제조업체에서 정한 허용기준을 만족하는 것으로 나타났다.

해안습지 성장률의 공간적 특성에 관한 연구 - 순천만 염하구 해안습지를 사례로 - (The Spatial Characteristics of Vertical Accretion Rate in a Coastal Wetland - In case of Sunchon bay estuarine marsh, south coast of Korea -)

  • 박의준
    • 한국지역지리학회지
    • /
    • 제6권3호
    • /
    • pp.153-168
    • /
    • 2000
  • 해안습지는 육지와 해양이 만나는 점이지대에 형성된 해안퇴적지형으로, 이 중 염하구는 하천과 조류의 영향이 갯강을 통해 직접적으로 미치는 만입형 해안습지이다. 따라서 하천과 조류에 의한 퇴적작용은 염하구의 성장과 발달에 있어서 가장 중요한 프로세스이다. 해안습지는 최근 중요한 환경문제로 대두되고 있는 해수면 상승의 영향을 직접적으로 받는 지형이기 때문에, 해안습지 성장률에 관한 연구는 해안환경의 이해와 관리에 있어 중요한 자료를 제공한다. 본 연구는 순천만 염하구 해안습지를 대상으로 상이한 시간단위 속에서 진행되는 퇴적률과 조류에 의한 부유하중의 이동패턴 분석을 토대로 해안습지 성장률의 공간적 특성을 밝히고자 하였다. 조석의 일주기간의 퇴적률은 경사변환점이 염생습지보다 높은 값을 나타내었으며, 하구에서 바다로 이동하면서 퇴적률이 감소하였다. 따라서 조석의 일주기간의 퇴적률에서는 갯강과 배후 갯벌사이 경사변환점의 제방효과와 부유하중의 농도가 중요하게 작용하였다. 연간 퇴적률은 염생습지가 경사변환점보다 높은 값을 나타내어 조석의 일주기간의 퇴적률과는 다른 공간적 특성을 보였다. 그러나 하구에서 바다로 이동하면서 퇴적률이 감소하는 것은 동일하였다. 따라서 연간 퇴적률에서는 식생에 의한 부유하중 고착능력과 조류의 정체시간, 부유하중의 농도가 중요하게 작용하였다. 조류내 부유하중의 농도는 전체적으로 썰물시 영생습지를 통과한 직후가 밀물시 경사변환점을 통과한 직후보다 높은 감소율을 나타내었다. 그리고 썰물시 경사변환점을 통과한 직후의 부유하중 농도는 오히려 약간 증가하였는데, 이는 썰물에 의해 경사변환점의 퇴적물이 침식되었기 때문이다. 연구지역의 퇴적률은 시간단위와 지점에 따라 다양한 특성을 보이면서 매우 빠르게 진행되고 있다. 경사변환점은 제방효과에 의한 퇴적과 조류 및 외부요인에 의한 침식이 동시에 일어난 반면, 염생습지는 조류의 정체시간과 식생에 의한 부유하중 포획에 따라 침식보다는 퇴적이 활발하게 일어났다. 따라서 연구지역의 성장률은 갯강을 중심으로 횡적으로는 염생습지가 경사변환점보다 높고, 종적으로하는 하구지점에 가까울수록 높게 나타났다. 특히, 지난 1년간의 성장률은 다른 지역에 비해서 매우 빠른 $0.9{\sim}3.5cm/yr$로 모든 지점에서 퇴적이 침식보다 우세하게 나타났는데, 이는 연구지역이 새로운 퇴적환경으로 전이되고 있는 것과 밀접한 관계가 있는 것이다.

  • PDF

드론을 활용한 지표온도와 흡수일사 간 공간적 상관관계 분석 - 쿨루프 효과 분석을 중심으로 - (Analysis of Spatial Correlation between Surface Temperature and Absorbed Solar Radiation Using Drone - Focusing on Cool Roof Performance -)

  • 조영일;윤동현;이명진
    • 대한원격탐사학회지
    • /
    • 제38권6_2호
    • /
    • pp.1607-1622
    • /
    • 2022
  • 본 연구의 목적은 도시폭염 저감을 위한 기법인 쿨루프를 연구지역에 적용하여 토지피복 객체 간 지표 온도와 흡수일사 간 공간적 상관관계 분석으로 실질적 효과 파악을 목적으로 한다. 이를 위해 실제 쿨루프가 적용된 경상남도 김해시 장유무계동 인근을 연구지역으로 선정하였으며, 드론 DJI Matrice 300 RTK에 열적외 영역센서 FLIR Vue Pro R, 가시광선 영역센서 H20T와 다중분광영역 센서인 Micasense Red-Edge를 활용하여 계측하였다. 계측 일정은 2021년 7월 27일 아침 7시 15분부터 약 1시간 30분 간격으로 총 9장의 열지도와 동일 시간대의 흡수일사 분포도, 쿨루프(113개) 및 일반옥상(367개) 지붕 객체를 추출하였다. 흡수일사 분포도는 ArcGIS의 3D 분석 기능인 Solar Radiation Analysis Tool을 통해 산출한 전천일사 분포도에 Micasense Red Edge를 통해 촬영한 Blue, Green Red, Near Infrared, Red Edge Range 영역대 센서의 조합을 통해 구축한 연구 지역의 알베도 값을 반영하여 구축한다. 전술된 자료를 기반으로 일반옥상과 쿨루프 지붕 객체별 지표온도와 흡수일사 간 Pearson 상관계수를 산출하였다. 분석 결과 일 평균 기준 일반옥상 0.550, 쿨루프 0.387의 상관계수 값을 나타내고 있었다. 하지만, 시간대별 상관성의 변화를 파악한 결과 분석일 기준 태양고도가 높은 시기인 11시 30분과 13시의 경우 일반옥상과 쿨루프 간 상관계수의 차이는 0.022, 0.024 값을 보여 유사한 상관성을 보이고 있다. 그 외 시간대는 일반옥상의 상관계수 값이 쿨루프 보다 약 0.1 이상 높은 값을 보이고 있다. 본 연구는 드론을 통해 취득한 고해상도 영상을 활용하여 쿨루프의 실질적 일사차단 영향의 가능성을 대조군이 되는 일반 옥상과의 상관성 비교를 통해 파악한 사례 연구이다. 향후 본 연구 결과를 기반으로 효율적인 도시열섬 저감기법 적용이 가능할 것으로 사료된다.

자연경관 조형화 가능성에 관한 연구 - 경남지역(남해가천마을, 산청임촌마을, 함양도마마을) 다랑이논을 중심으로 - (A Study on Natural Scene Figuration Possibility - Centering around Gyeongnam Area(Namhae Gacheon Village, Sancheong Imchon Village, Hamyang Doma Village) Rice Terraces -)

  • 윤경숙;이재근
    • 한국전통조경학회지
    • /
    • 제28권1호
    • /
    • pp.113-119
    • /
    • 2010
  • 본 연구는 다랑이논의 조형성에 관한 연구로 경남지역 남해 가천다랑이논, 산청 임천다랑이논, 함양 마천다랑이논을 선정하여 자연경관의 조형 가능성을 모색하는 시도로 사례분석을 통하여 그 가능성을 제시하고자 하였다. 이론적 배경으로 자연경관의 연구 및 조형관련 연구를 살펴보았으며, 이를 바탕으로 자연경관을 조형화 시키기 위하여, 지형에서 나타나는 다랑이논의 자연경관적 특성과 공간적 특성에서 얻어진 다랑이논 지형의 특성을 모두 9개 항목으로 나누었다. 그 내용으로 (1) 다랑이논의 경사 완급을 나타내는 경사도, (2) 다랑이논 가장자리 선의 요철이 보여주는 굴곡도, (3) 상하 가장자리 선의 평행성정도, (4) 각 다랑이논 단면의 폭의 크기, (5) 전체 다랑이논의 넓이, (6) 상하 다랑이논의 높낮이 차이를 나타내는 단차, (7) 전체적 다랑이논의 외형적 형태가 지닌 이미지로서의 형상성, (8) 전체적 경관이 지닌 자연스러움과 인위성, (9) 다랑이논을 형성하고 있는 축석이나 토양의 부드러움, 전체적인 경관에서 풍기는 분위기 등이다. 사례대상지를 문헌조사와 현지답사, GIS를 통해 분석한 주요결과는 다음과 같다. 첫째, 다랑이논의 경사가 심할수록 축석의 단차가 높아지고 면적과 폭에서는 급경사일수록 좁아짐으로써, 경사와 단차이에서는 비례적 관계 경사를 나타내고, 다랑이논 부지의 면적과 폭에서는 반비례로 나타나는 것을 알 수 있었다. 둘째, 다랑이논을 바라볼 때 보여지는 대상물이 갖는 선적, 면적 요소와 중첩, 반복되는 변화, 계절에 따른 변화, 산세, 계곡과 하천 등 주변환경과의 연계로 인한 경관의 변화는 개인의 성향에 따라 다양한 형상으로 이미지화할 수 있을 것으로 사료된다. 셋째, 각 대상지에서 도출되는 공통적인 형태로 반복구성과 방향성, 운동성, 질서와 변화 등을 조형요소화 하는 것이 가능할 것으로 판단되었다. 본 논문은 자연경관을 대상으로 조형성을 표현하기 위한 기초자료 연구로서 사례대상지의 주변 환경을 조사 분석하였으며, 대상지의 환경적 아름다움을 하나의 조형요소로 일반화할 수 있는 가능성을 시도했다는데 의미가 있으며, 보다 정밀한 연구는 추후 과제로 남겨두기로 한다.

방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정 (Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System)

  • 추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제14권1호
    • /
    • pp.77-85
    • /
    • 1996
  • 목적 : 다엽콜리메이터를 이용하여 부정형의 치료부위를 편리하고 정확히 차폐하며 삼차원 입체조형치료를 원활히 수행하기 위하여 다엽콜리메이터의 차폐특성을 계측하고 치료계획을 위한 최적방법을 확정한다. 대상 및 방법 : 차폐폭이 1cm이고 길이가 15cm인 52개의 금속차폐엽들이 양방향 각각 26개로 구성되어 컴퓨터계획에 의거 여러모양의 차폐면을 구사할 수 있는 다엽콜리메이터(Multileaf collimator)를 대상으로 방사선 치료에 요구되는 고에너지 방사선의 출력선량율, 차폐 및 투과효과, 반음영, 조직내 선량분포등을 전리함측정기와 열형광측정기 및 필름 선량측정방법을 이용하여 계측하였다. 다엽콜리메이터의 계단식 반음영 측정은 고체팬텀과 비디오밀도측정기를 이용하여 실효반음영(Effective penumbra)과 일반적반음영(General penumbra)으로 구분 평가하였다. 결과 : 다엽콜리메이터의 출력선량율은 표준차폐조리개에 비교하여 출력 선량율이 $1-2\%$ 증가 되었으며 치료오차 이내로 평가되었다. 다엽콜리메이터의 방사선투라 선량율은 6-10MV X선에서 평균 $2\%$로 표준차폐조리개보다 컸지만 혼합차폐벽돌보다 적었다. 원형으로 형성된 차폐엽 끝면의 조사선량은 약 $20\%$증가 되었으며 엽과 엽사이의 선량은 6mm 폭의 $5\%$증가로 심부치료에 영향이 없었다. 다엽콜리메이터의 실효반음영($20-80\%$)은 약 6mm로서 혼합차폐벽돌과 거의 같았으나 중심선에서 벗어날수록 $2-3\%$증가되었다. 다엽콜리메이터에 의한 계단식 모양의 반음영은 6-10MV x-선에서 차폐면 경사각이 45도일 때 약 11mm로 가장 컸으며 방사선속에 평행히 절단된 차폐벽돌보다 약 5mm 더 증가되었다. 결론 : 다엽콜리메이터는 1cm폭의 차폐엽들로 구성되어 계단식 차폐면에 대한 반음영이 다소 증가되고 있지만 조직내부의 다문조사 경우 반음영이 완화되므로 부정형 조사면 차폐에 적당하며 방사선 입체조형치료를 수행할 수 있는 가장 적당한 차폐기구로 생각된다.

  • PDF