• Title/Summary/Keyword: device development

Search Result 5,566, Processing Time 0.037 seconds

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

The Effects of Growth Temperature and Substrate Tilt Angle on GalnP/GaAs Tandem Solar Cells

  • Jun, Dong-Hwan;Kim, Chang-Zoo;Kim, Hog-Young;Shin, Hyun-Beom;Kang, Ho-Kwan;Park, Won-Kyu;Shin, Ki-Soo;Ko, Chul-Gi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • The performance of GaInP/GaAs tandem solar cells with AlInP growth temperatures of 680$^{\circ}C$ and 700 $^{\circ}C$ on n-type GaAs (100) substrate with 2$^{\circ}$ and 6$^{\circ}$ tilt angles has been investigated. The series resistance and open circuit voltage of the fabricated tandem solar cells are affected by the substrate tilt angles and the growth temperatures of the window layer when zinc is doped in the tunnel diode. With carbon doping as a p-type doping source in the tunnel diode and the effort of current matching between top and bottom cells, GaInP/GaAs tandem solar cell has been exhibited 25.58% efficiency.

A Study of Orthognathic Surgical Guides with Two-stage Split Path (2단 절개 형태를 가지는 악교정 수술 장치 연구)

  • Min Uk, Kim;Chung Hwan, Park;Ji Hyoung, Rho;Eui Sung, Jung;Young Sang, Park;Dong Guk, Kim;Yohan, Seo;Young Jea, Woo;Jong Min, Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

A Study on Development of Wireless Check-up Device for Captive Flight Test (탑재비행시험용 무선 점검장치 개발에 대한 연구)

  • Ryu, Sang-Gyu;Joo, Junghyun;Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Blazed $GxL^{TM}$ Device for Laser Dream Theater at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nishida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.556-559
    • /
    • 2006
  • We successfully developed a high performance and highly reliable blazed GxL device with a high optical efficiency and a high contrast ratio. The device demonstrated superior resistance against a high power laser, which is suitable for a large-area laser projector. We operated the world's largest laser projection screen using this device at the 2005 World Exposition in Aichi, Japan, problem free.

  • PDF

Simplified Parametric Study on M125 Booster Mechanism and its Application for Determining the Characteristic Constant of Arming Distance (M125 부스터 메카니즘의 해석 및 응용)

  • Rim, One kwon;Kim, Sung shik;Bang, Jae won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.409-414
    • /
    • 2015
  • M125 booster is one of the reliable S&A device(safety and arming device) to determine the arming distance of fuze for gun ammunitions from 90 mm to 8 inch in diameter. And it is also well known that the arming distance of M125 booster is determined by the multiplication value of the gun tube property(traveled distance per turn of projectile) and the S&A device property(number of turns to arm), not by the projectile muzzle velocity. We have tried and succeeded in executing a proper analysis on M125 booster to figure out its characteristic constant of arming distance by considering only the gun tube properties and the S&A device properties. More detailed arming distance will be analyzed in the future by considering dynamic characteristics on all elements in the S&A device with vector analysis.

Development of Rotary Type Transplanting Device for Vegetable Transplanter (채소정식기용 로터리 식부장치 개발)

  • Park S. H.;Cho S. C.;Kim J. Y.;Choi D. K.;Kim C. K.;Kwak T. Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.135-140
    • /
    • 2005
  • Vegetable transplanting operation has been wholly depended on human labor that needs 18.4 hrs per 10 acres in Korea. Since periods of vegetable transplanting operations are limited, their mechanization has been strongly demanded. This study was conducted to develop a transplanting device that was the core technology for vegetable transplanter. In order to find out transplanting track and velocity of transplanting device, a kinematic analysis software was employed. Evaluation of prototype was carried out in the circular soil bin with high speed camera. Rotary type transplanting device produced an elliptic loci when two links of different lengths were moving to the opposite direction. The length of two links was 75mm and 44mm, respectively. Maximum displacement of rotary type transplanting device was 238mm. It seemed that the transplanting elliptic loci of transplanting device were identical between the simulation output generated by kinematic analysis software and the circular soil bin test result with a high speed camera. The rotary type transplanting device can be suitable fur transplanting short height vegetable, less than 20 cm length vegetables such as Chinese cabbage and cabbage, etc.

A Study on the Performance Prediction and Evaluation of Scale Down Noise Reducing Device on the Top of Noise Barrier (축소모형 방음벽 상단장치의 성능예측 및 평가에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Hong, Byung-Kook
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2844-2851
    • /
    • 2011
  • The purpose of this study is to set up an acoustic prediction technique and to perform the IL test of scale down noise reducing device for the development of the noise reducing device as the development of 400km/h class high speed train. First of all, the IL prediction of noise reducing device was performed with the 2D BEM method. And the noise test of scale down noise reducing device in anechoic chamber was performed for the verification of acoustic prediction technique and IL performance evaluation. As the results, the acoustic prediction technique for the development of noise reducing device was verified because the averaged IL difference between prediction and test is in 2dB(A). And the measured IL value of noise reducing device is less than 2dB(A), and additional IL with polyester absorption material is increased about 0.5dB(A).

  • PDF

Development Life Cycle-Based Association Analysis of Requirements for Risk Management of Medical Device Software (의료기기 소프트웨어 위험관리를 위한 개발생명주기 기반 위험관리 요구사항 연관성 분석)

  • Kim, DongYeop;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.12
    • /
    • pp.543-548
    • /
    • 2017
  • In recent years, the importance of the safety of medical device software has been emphasized because of the function and role of the software among components of the medical device, and because the operation of the medical device software is directly related to the life and safety of the user. To this end, various standards have been set up that provide activities that can effectively ensure the safety of medical devices and provide their respective requirements. The activities that standards provide to ensure the safety of medical device software are largely divided into the development life cycle of medical device software and the risk management process. These two activities should be concurrent with the development process, but there is a limitation that the risk management requirements to be performed at each stage of the medical device software development life cycle are not classified. As a result, developers must analyze the association of standards directly to develop risk management activities during the development of medical devices. Therefore, in this paper, we analyze the relationship between medical device software development life cycle and risk management process, and extract risk management requirement items. It enables efficient and systematic risk management during the development of medical device software by mapping the extracted risk management requirement items to the development life cycle based on the analyzed associations.

The Design and Test of the Electronic Arm Fire Device Circuit (전자식 점화안전장치 회로부 설계 및 검증)

  • Gim, Hakseong;Hwang, Jung-Min;Jang, Seung-gyo;Kim, Jae-Hoon;Hwang, Dae-Gyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.857-864
    • /
    • 2018
  • This paper describes about the circuit design and test of the electronic Arm Fire Device. Electronic arm fire device consists of igniter, circuit and housing case and it operates without the actuator such as torque motor or solenoid. A high-voltage DC-DC converter was used to generate the voltage for initiating the LEEFI(Low Energy Exploding Foil Initiator). The MEMS switch was used to detect the acceleration that occurs when missile is launched, and the circuit was designed considering the size, performance, and specification of the electronic devices. The performance test was conducted to verify the designed circuit and we confirmed that it operates well.