• 제목/요약/키워드: device development

검색결과 5,566건 처리시간 0.035초

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

The Effects of Growth Temperature and Substrate Tilt Angle on GalnP/GaAs Tandem Solar Cells

  • Jun, Dong-Hwan;Kim, Chang-Zoo;Kim, Hog-Young;Shin, Hyun-Beom;Kang, Ho-Kwan;Park, Won-Kyu;Shin, Ki-Soo;Ko, Chul-Gi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권2호
    • /
    • pp.91-97
    • /
    • 2009
  • The performance of GaInP/GaAs tandem solar cells with AlInP growth temperatures of 680$^{\circ}C$ and 700 $^{\circ}C$ on n-type GaAs (100) substrate with 2$^{\circ}$ and 6$^{\circ}$ tilt angles has been investigated. The series resistance and open circuit voltage of the fabricated tandem solar cells are affected by the substrate tilt angles and the growth temperatures of the window layer when zinc is doped in the tunnel diode. With carbon doping as a p-type doping source in the tunnel diode and the effort of current matching between top and bottom cells, GaInP/GaAs tandem solar cell has been exhibited 25.58% efficiency.

2단 절개 형태를 가지는 악교정 수술 장치 연구 (A Study of Orthognathic Surgical Guides with Two-stage Split Path)

  • 김민욱;박충환;노지형;정의성;박영상;김동국;서요한;우영재;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

탑재비행시험용 무선 점검장치 개발에 대한 연구 (A Study on Development of Wireless Check-up Device for Captive Flight Test)

  • 류상규;주정현;고명준
    • 한국군사과학기술학회지
    • /
    • 제22권4호
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Blazed $GxL^{TM}$ Device for Laser Dream Theater at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nishida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.556-559
    • /
    • 2006
  • We successfully developed a high performance and highly reliable blazed GxL device with a high optical efficiency and a high contrast ratio. The device demonstrated superior resistance against a high power laser, which is suitable for a large-area laser projector. We operated the world's largest laser projection screen using this device at the 2005 World Exposition in Aichi, Japan, problem free.

  • PDF

M125 부스터 메카니즘의 해석 및 응용 (Simplified Parametric Study on M125 Booster Mechanism and its Application for Determining the Characteristic Constant of Arming Distance)

  • 임완권;김성식;방재원
    • 한국군사과학기술학회지
    • /
    • 제18권4호
    • /
    • pp.409-414
    • /
    • 2015
  • M125 booster is one of the reliable S&A device(safety and arming device) to determine the arming distance of fuze for gun ammunitions from 90 mm to 8 inch in diameter. And it is also well known that the arming distance of M125 booster is determined by the multiplication value of the gun tube property(traveled distance per turn of projectile) and the S&A device property(number of turns to arm), not by the projectile muzzle velocity. We have tried and succeeded in executing a proper analysis on M125 booster to figure out its characteristic constant of arming distance by considering only the gun tube properties and the S&A device properties. More detailed arming distance will be analyzed in the future by considering dynamic characteristics on all elements in the S&A device with vector analysis.

채소정식기용 로터리 식부장치 개발 (Development of Rotary Type Transplanting Device for Vegetable Transplanter)

  • 박석호;조성찬;김진영;최덕규;김충길;곽태용
    • Journal of Biosystems Engineering
    • /
    • 제30권3호
    • /
    • pp.135-140
    • /
    • 2005
  • Vegetable transplanting operation has been wholly depended on human labor that needs 18.4 hrs per 10 acres in Korea. Since periods of vegetable transplanting operations are limited, their mechanization has been strongly demanded. This study was conducted to develop a transplanting device that was the core technology for vegetable transplanter. In order to find out transplanting track and velocity of transplanting device, a kinematic analysis software was employed. Evaluation of prototype was carried out in the circular soil bin with high speed camera. Rotary type transplanting device produced an elliptic loci when two links of different lengths were moving to the opposite direction. The length of two links was 75mm and 44mm, respectively. Maximum displacement of rotary type transplanting device was 238mm. It seemed that the transplanting elliptic loci of transplanting device were identical between the simulation output generated by kinematic analysis software and the circular soil bin test result with a high speed camera. The rotary type transplanting device can be suitable fur transplanting short height vegetable, less than 20 cm length vegetables such as Chinese cabbage and cabbage, etc.

축소모형 방음벽 상단장치의 성능예측 및 평가에 관한 연구 (A Study on the Performance Prediction and Evaluation of Scale Down Noise Reducing Device on the Top of Noise Barrier)

  • 윤제원;김영찬;장강석;홍병국
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2844-2851
    • /
    • 2011
  • The purpose of this study is to set up an acoustic prediction technique and to perform the IL test of scale down noise reducing device for the development of the noise reducing device as the development of 400km/h class high speed train. First of all, the IL prediction of noise reducing device was performed with the 2D BEM method. And the noise test of scale down noise reducing device in anechoic chamber was performed for the verification of acoustic prediction technique and IL performance evaluation. As the results, the acoustic prediction technique for the development of noise reducing device was verified because the averaged IL difference between prediction and test is in 2dB(A). And the measured IL value of noise reducing device is less than 2dB(A), and additional IL with polyester absorption material is increased about 0.5dB(A).

  • PDF

의료기기 소프트웨어 위험관리를 위한 개발생명주기 기반 위험관리 요구사항 연관성 분석 (Development Life Cycle-Based Association Analysis of Requirements for Risk Management of Medical Device Software)

  • 김동엽;박예슬;이정원
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제6권12호
    • /
    • pp.543-548
    • /
    • 2017
  • 최근에는 의료기기의 구성 요소 중 소프트웨어의 기능과 역할이 커지고, 의료기기 소프트웨어의 작동이 사용자의 생명과 안전에 직결되는 특성으로 인해 의료기기 소프트웨어의 안전성 보장에 대한 중요함은 더욱 강조되고 있다. 이를 위해 의료기기의 안전성을 효과적으로 보장할 수 있는 활동과 각각의 요구사항들을 제시하고 있는 여러 표준이 제정되었다. 표준들이 의료기기 소프트웨어의 안전성을 보장하기 위해 제시하는 활동으로는 크게 의료기기 소프트웨어의 개발생명주기와 위험관리 프로세스로 나뉜다. 이 두 활동은 개발 과정 중 동시에 진행되어야 하지만, 의료기기 소프트웨어 개발생명주기의 각 단계에서 수행되어야하는 위험관리 요구사항들은 분류되어있지 않다는 한계점이 있다. 이로 인해 개발자들은 의료기기 개발 중에 직접 표준들의 연관성을 분석하여 위험관리 활동을 수행해야한다. 따라서 본 논문에서는 의료기기 소프트웨어 개발생명주기와 위험관리 프로세스의 연관성을 분석하고, 위험관리 요구사항 항목들을 추출한다. 그리고 분석한 연관성을 토대로 추출된 위험관리 요구사항 항목을 개발생명주기에 대응시킴으로서, 의료기기 소프트웨어의 개발 중 효과적이고 체계적인 위험관리를 가능하게 한다.

전자식 점화안전장치 회로부 설계 및 검증 (The Design and Test of the Electronic Arm Fire Device Circuit)

  • 김학성;황정민;장승교;김재훈;황대규
    • 한국군사과학기술학회지
    • /
    • 제21권6호
    • /
    • pp.857-864
    • /
    • 2018
  • This paper describes about the circuit design and test of the electronic Arm Fire Device. Electronic arm fire device consists of igniter, circuit and housing case and it operates without the actuator such as torque motor or solenoid. A high-voltage DC-DC converter was used to generate the voltage for initiating the LEEFI(Low Energy Exploding Foil Initiator). The MEMS switch was used to detect the acceleration that occurs when missile is launched, and the circuit was designed considering the size, performance, and specification of the electronic devices. The performance test was conducted to verify the designed circuit and we confirmed that it operates well.