Study on the Prediction of Concrete Deterioration Subjected to Cyclic Freezing and Thawing (동결융해작용을 받는 콘크리트의 열화예측에 관한 연구)

  • 고경택;이종석;이장화;조명석;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.795-798
    • /
    • 1999
  • Deterioration induced by the freezing and thawing in concrete often leads to the reduction in concrete durability by the cracking or surface spalling. In this paper, the deterioration prediction model for concrete structures subjected to the irregular freeze-thaw was proposed from the results of accelerated laboratory test using the constant temperature condition and acceleration factor from the in-situ weather data.

  • PDF

A RELIABILITY-BASED CAPACITY RATING OF EXISTING BRIDGES BY INCORPORATING SYSTEM IDENTIFICATION (동특성 추정 기법과 신뢰성 해법에 의한 기설교량의 내하력 판정 방법)

  • Cho, Hyo-Nam;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.04a
    • /
    • pp.37-43
    • /
    • 1990
  • This paper develops practical models and methods for the assessment of safety and rating of damaged and/or deteriorated bridges by incorporating a system identification technique for the explicit inclusion of the degree of deterioration or damage and of the actual bridge response. And, based on the proposed model, reliability-based rating methods are proposed as LRFR(Load and Resistance Factor Rating) and system reliability-index rating criteria. The proposed limit state model explicitly accounts for the degree of deterioration or damage in terms of the damage and response factors. The damage factor in the paper is proposed as the ratio of the current stiffness to the intact stiffness. Based on the observation and the results of applications to existing bridges, it may be concluded that the proposed rating models, which explicitly account for the uncertainties and the effects of degree of deterioration or damage based on the system identification technique, provide more realistic and consistent safety-assessment and capacity-rating.

  • PDF

A Study on the Scaling Deterioration and Resistance to Freezing of Concrete by Containing Chlorides (염화물 함유에 의한 콘크리트의 내동해성 및 표면열화에 관한 연구)

  • Park Joo Houn;Kim Gyu Yong;Kim Han Jun;Kwon Yeong Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.372-375
    • /
    • 2004
  • Scaling deterioration and resistance to freezing of port concrete structures due to the combined effects of chemical actions by containning chlorides and the freeze-thaw action is also a problem which has not yet been fundamentally solved. Furthermore, deterioration of concrete surface was considered as accelerate factor of concrete durability tended to decrease. Therefore, we considered the scaling measuring method and decreasing influence of durability of concrete according to kind of binders, such as OPC, Slag, Slag+Fa, due to freeze and thaw of concrete by containing chlorides. As a results of this study, it was effective method of scaling deterioration and resistance freewing of concrete, and confirmed the salt deterioration resistance effect to use slag binder against to containing chlorides.

  • PDF

A Study on the Concrete Scaling Deterioration due to Freezing and Thawing of Sea Water (해수동결융해작용에 의한 콘크리트의 표면열화에 관한 연구)

  • 김규용;박주현;김규동;이승훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.54-57
    • /
    • 2003
  • Scaling deterioration of port concrete structures due to the combined effects of chemical actions by seawater and the freeze-thaw action is also a problem which has not yet been fundamentally solved. Furthermore, deterioration of concrete surface was considered as accelerate factor of concrete durability tended to decrease. Therefore, we considered the scaling measuring method and decreasing influence of durability of concrete according to kind of binders, such as OPC, Slag, Slag+Fa, due to freeze and haw of sea water. As a results of this study, it was effective method of scaling deterioration of concrete, and confirmed the salt deterioration resistance effect to use slag binder against to sea water.

  • PDF

A Study on the Dynamic Behaviors of Ballast Track using Field Test (현장측정을 통한 자갈도상궤도의 동적 거동 분석)

  • Park Yong-Gul;Choi Jung-Youl
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.401-411
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

A Study on the Dynamic Behaviors of Ballast Track using Field Test (현장측정을 통한 자갈도상 궤도의 동적 거동 분석)

  • Choi, Jung-Youl;Park, Kyun-Seo;Ryu, Joong-Youl;Park, Jeong-Gun;Ryu, Kyoung-Sik;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.494-507
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

A Study on the Target Values Fixing of Green Vehicle Emissions in Consideration of In-use Deterioration (운행차 열화특성을 고려한 제작차 배출가스 목표치 설정에 관한 연구)

  • 김현우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.104-110
    • /
    • 2003
  • As exhaust emission standards are more stringent, higher conversion efficiency of automotive catalytic converter is required. In addition, catalytic converter is deteriorated during mileage accumulation of vehicle. Therefore the specification of catalytic converter should be decided in consideration of emission standards and deterioration. Because the decision of the specification of catalytic converter is required at the beginning of vehicle development procedure, it is important and necessary to fix the target values of green vehicle exhaust emissions. To do this, a linear regression analysis was done with in-use exhaust emissions data of 5 different kinds of vehicle that received US94 emission standards certification, and data handling methods including some statistical estimation were proposed. As a result, the fixed target values of NMHC, CO, NOx of green vehicle against US94 emission standards were 0.079, 0.83, 0.116, respectively. And expected in-use deterioration factor of NMHC, CO, NOx were 1.75, 2.02, 1.38, respectively. And also it was blown that even if failure rate is 30% after 80,000km driven, it might be sufficiently safe from emission failure confirmatory test of Korea. It is hopeful to make a database of in-use emissions to increase the confidence in correctness of the calculated target values.

A Study on Chemical Characteristic of Electrically and Thermally Treated MPPF Capacitor Elements (MPPF 커패시터의 전기적, 열적 열화시 소체의 화학적특성에 관한 연구)

  • Koo, Kyo-Sun;Song, Hyun-Seok;Lee, Dong-Zoon;Kwak, Hee-Ro;Shong, Kil-Mok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.227-230
    • /
    • 2001
  • This paper divides the factors of an accident into two parts, that are electrical deterioration and thermal deterioration, to analyze a characteristic of the factor of an accident which can break out in the capacitor of metal vaporized polypropylene film. For the purpose of creating capacitor which is caused by electric deterioration, we applied DC overvoltage, induced self-healing and breakdown from element. We applied gradual heat to get an element which is cause by thermal deterioration. The chemical structure of the shape and surface is analyzed by thermogravimetric analyzer (TGA), Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectrometer(FT-IR). As a result, the peak of methylene group came out, in case of electrical deterioration, as observing the self-healing point. However, the peak is disappeared in the heat treated element by 500[$^{\circ}C$], and the peak of carbonyl group which has C=O came out in case of thermal deterioration.

  • PDF

Factor Analysis of Deterioration in Namhansanseong Yeojang (남한산성 여장 손상원인 분석)

  • Chung, Kwang-Yong;Lee, Sang-Ok;Yang, Hee-Jae
    • Journal of architectural history
    • /
    • v.25 no.1
    • /
    • pp.59-68
    • /
    • 2016
  • There are many reasons of damage in Namhansanseong Yeojang. Lots of damage types are observed in each Yeojang. There are many types of damage factors but major damage factor is breakage by freezing and thawing. So Conduct non-destructive evaluation about damage factors in Namhansanseong Yeojang to analysis weathering factors in Yeojang by measuring directional microclimate. The study will pave the way for conservation management in Namhansanseong by suggesting the conservation calendar about weather condition and damage factors.

A Study on the Distribution of the Deterioration Factor for Three Pollutants in Motor Vechicle Emission Test (자동차(自動車) 배출(排出)가스 시험(試驗)에서 3 공해요소(公害要素)에 대한 변화요인(變化要因) (DF) 분포(分布)에 관한 연구(硏究))

  • Jo, Jae-Rip;Hwang, Ui-Cheol
    • Journal of Korean Society for Quality Management
    • /
    • v.15 no.2
    • /
    • pp.2-9
    • /
    • 1987
  • The Deterioration Factor (DF) for a single pollutant within an engine family is computed as the ratio of two points on a linear regression line describing durability vehicle test results as a function of accumulated mileage. It is inteded to represent the factor by which emissions will increase during the ''useful life" of a vehicle in the engine family. Here are discribed procedures for computing the DF and how consideration of the DF is included in the development for the motor vehicle emission certification process. This paper is aimed to develop the distribution of the DF for three pollutant and to estimate the parameter values for the distribution of the DF.

  • PDF