• Title/Summary/Keyword: desulfurization

Search Result 353, Processing Time 0.027 seconds

Studies on the Desulfurization of 1,3,4-Oxathiazol-2-one and 1,2,4-Dithiazol-3-one with Trivalent Phosphorus Compounds (1,3,4-옥사티아졸-2-온과 1,2,4-디티아졸-3-온의 3가인 화합물과의 탈황반응에 관한 연구)

  • Dong Young Oh;Chung Ryeol Kim
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.368-375
    • /
    • 1983
  • The reactions of various 5-aryl-1,3,4-oxathiazol-2-ones with triethylphosphite resulted in the formation of the corresponding benzonitriles and ethylphosphorothioate by desulfurization reaction in 66∼94% yields. 5-(4-Nitrophenyl)-1,3,4-oxathiazol-2-one was also reacted with trimethylphosphite, triethylphosphine, and triphenylphosphine to give 4-nitrobenzonitrile. But it did not react with triphenylphosphate. The reactions of 5-(4-bromophenyl)-1,2,4-dithiazol-3-one with triphenylphosphine resulted in the formation of 4-bromothiobenzoyl isocyanate and triphenylphosphine thioxide. The thioacyl isocyanate was fragmented into nitrile in ether but was stable in chloroform. This desulfurization reaction observed in each reaction may proceed by the intramolecular rearrangement after insertion of the phosphorus compound into the ring. The stable thioacyl isocyanate in chloroform reacted with imine to give 1,3,5-thiadiazin-4-one via 1,4-cycloaddition reaction.

  • PDF

Direct Synthesis of H2O2 over Ti-Containing Molecular Sieves Supported Gold Catalysts: A Comparative Study for In-situ-H2O2-ODS of Fuel

  • Zhang, Han;Liu, Guangliang;Song, Haiyan;Chen, Chunxia;Han, Fuqin;Chen, Ping;Zhao, Zhixi;Hu, Shaozheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.3065-3072
    • /
    • 2013
  • Direct synthesis of $H_2O_2$ and in situ oxidative desulfurization of model fuel over Au/Ti-HMS and Au/TS-1 catalysts has been comparatively investigated in water or methanol. Maximum amount (82%) of active $Au^0$ species for $H_2O_2$ synthesis was obtained. Au/Ti-HMS and Au/TS-1 exhibited the contrary performances in $H_2O_2$ synthesis as $CH_3OH/H_2O$ ratio of solvent changed. $H_2O_2$ decomposition and hydrogenation in water was inhibited by the introduction of methanol. Effect of $O_2/H_2$ ratio on $H_2O_2$ concentration, $H_2$ conversion and $H_2O_2$ selectivity revealed a relationship between $H_2O_2$ generation and $H_2$ consumption. The highest dibenzothiophene removal rate (83.2%) was obtained over Au/Ti-HMS in methanol at 1.5 of $O_2/H_2$ ratio and $60^{\circ}C$. But removal of thiophene over Au/TS-1 should be performed in water without heating to obtain a high removal rate (61.3%). Meanwhile, $H_2$ conversion and oxidative desulfurization selectivity of $H_2$ were presented.

Numerical Simulation of Catalyst Regeneration Process for Desulfurization Reactor (수치해석을 통한 탈황반응기용 촉매의 재생공정 분석)

  • Choi, Chang Yong;Kwon, Sang Gu;Liu, Jay;Im, Do Jin
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.140-147
    • /
    • 2017
  • In this study, we performed numerical simulation for the catalyst regeneration process of diesel desulfurization reactor. We analyzed the changes in regeneration process according to purge gas flow rate, catalyst permeability, reactor size, and heat loss of reactor. We have found that the regeneration process is very much affected by temperature changes whereas it is hardly affected by catalyst permeability and porosity. We also estimated the regeneration time according to purge gas flow rate and initial temperatures and have found that increasing purge gas temperature is more effect for fast regeneration. The present results can be utilized to design a regeneration process of diesel desulfurization reactor for a fuel cell used in ships. Furthermore, the present work also can be used to design low sulfur diesel supply in oil refineries and therefore contribute to the development of clean petrochemical technology.

Study on the corrosion resistance of coating mixture to acid for the desulfurization system (탈황설비용 탄소강 코팅조성물의 내산성에 관한 연구)

  • Kim, In-Ki;Ryu, Jeong-Koon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.6
    • /
    • pp.278-285
    • /
    • 2006
  • Coating mixtures of the resin B-H for the application to the desulfurization system of power plant were coated on carbon steels and cured at the temperature of $65^{\circ}C{\sim}80^{\circ}C$. After being contacted with 70wt% $H_2SO_4$ solution of $100^{\circ}C\;and\;120^{\circ}C$ for several hours, their composition, Vicker's hardness and microstructures by SEM were examined. Corrosion resistance of the coating mixtures to $H_2SO_4$ solution was related to the content of $SO_3$ in the coated specimens after corrosion test. The lower curing temperature and the shorter curing time the coated specimens went through, the higher corrosion resistance to acid they showed, but the more cracks were developed at higher temperature. It was realized that the corrosion resistance to sulfaric acid solution was increased on the condition of curing temperature above $65^{\circ}C$ and curing time above 12 hours at least.

Influence of Physicochemical Characteristic of Donghae-Samcheok Limestones on the Performance of Flue Gas Desulfurization (FGD) (동해-삼척지역 석회석의 물리화학적 특성이 탈황성능에 미치는 영향)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Kwon, Woo-Tech;Cho, Kye-Hong;Ahn, Ji-Whan
    • Resources Recycling
    • /
    • v.24 no.6
    • /
    • pp.38-44
    • /
    • 2015
  • It studies that effect of limestone of physicochemical characteristic on the performance of flue gas desulfurization (FGD) and application examination for technology of wet type FGD process and to utilize the limestone in Donghae-Samcheok. The experiment method was measured total neutralizing capability (TNC) using the lab scale experimental apparatus based on the HCl titration test. The results of TNC of limestone samples were more dependent on the physical characteristics including particle size rather than chemical compositions such as CaO content and particle size of limestone get smaller, TNC is increased.

A study on the Effects of Crystal Structure of Domestic High-Ca Limestones on the Grinding and Dissolution Rates in the Simulated Spray Type Absorption Tower (스프레이 모사 흡수탑에서 국내 고품위 석회석의 결정구조가 분쇄 및 용해도에 미치는 영향 연구)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Cho, Jin-Sang;Ahn, Ji-Whan;Cho, Kye-Hong
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.10-19
    • /
    • 2017
  • It is studied the effect of crystal structure of domestic High-Ca limestones using absorbent for desulfurization on the grinding characteristics and dissolution rates in wet flue gas desulfurization process of domestic coal fired power plant. It compared the crystal structure, grinding work index and dissolution rates with 4 Limestones from Jecheon-Danyang with different crystal structure, and we found that grinding work index differ in crystal size and crystal structure of limestones : The lower the value of the grinding work index is, the higher the dissolution rates of limestones. Confirmed that we have important indicators of grinding characteristics for crystal structure with CaO content of limestones.

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

A Study on the Application with Limestone Sludge at Limestone-Gypsum Wet Flue Gas Desulfurization Process (석회석 슬러지의 석회석-석고 습식 배연탈황 공정적용에 관한 연구)

  • Seo, Sung Kwan;Chu, Yong Sik;Shim, Kwang Bo
    • Resources Recycling
    • /
    • v.25 no.5
    • /
    • pp.44-49
    • /
    • 2016
  • Flue gas desulfurization(FGD) is an effective technique to remove $SO_2$ gases of coal-fired plants. Limestone is usually used as desulfurizing agent. In this study, we use the limestone sludge which is a by-product of steel industry in order to replace desulfurizing agent of FGD process. Physical and chemical characteristics analysis of desulfurizing agent was conducted. Desulfurizing agent using limestone sludge was fabricated by pre-treatment process and, then the agent was used on FGD process. Consequently, the tendency on the $SO_2$ concentration did not appear. And limestone sludge was considered as possible alternative agent for flue gas desulfurization process through absorber control system.

Desirable pH of Slurry in Desulfurization Absorber for a 1000 MW Coal Fired Power Plant (1000 MW급 석탄화력발전용 탈황흡수탑의 적정슬러리 pH)

  • Park, Jeong-kee;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.1
    • /
    • pp.38-44
    • /
    • 2019
  • This research is an experimental investigation to find the desirable pH of slurry in the desulfurization absorber for a 1000 ㎿ coal fired power plant, operating in compliance with the Air Environmental Conservation Act and the plant's internal regulations. In case the average sulfur dioxide concentration in inflow flue gas, ${\bar{C\;in}}$ [ppm] changed to 500 ppm, 550 ppm, 600 ppm and 635 ppm after fixing inflow flue gas flow rate, generator output, pressure drop in the absorber, and oxidation air flow rate, the desirable pH of the slurry in the absorber, was 5.0, 5.2, 5.3 and 5.4. Thus, it is recommended that the desirable pH of slurry is calculated using the correlation equation, $RpH=0.0018{\times}{\bar{C\;in}}+4,2031$ when the average sulfur dioxide concentration in the inflow flue gas is in the range of 500 ppm to 635 ppm.

Characteristics of Concrete Using Ready-Mixed Concrete Recycled Water Mixed with Industrial By-Product Desulfurization Gypsum (산업부산물 탈황석고 혼입 레디믹스트콘크리트 회수수를 이용한 콘크리트의 특성)

  • Kim, Young-Yeop;Lee, Han-Seung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.395-403
    • /
    • 2020
  • CaO-based by-product, which consist of CaO, SO3, Al2O3 and so on, has being used to raw materials of CaO compound. When It was applied to recycling water of remicon, concrete performance can be enhanced because hydration reaction of powder material is accelerated. In this study, activated-sludge, which was putted desulfurization gypsum of CaO-based in recycling water, was manufactured to verify effect of them, and then they was investigated by characteristics of redy-mixde concrete. As a result of concrete tests, it was confirmed that there is no problem of strength or drying shrinkage while ensuring workability. Therefore, the possibility of specific application using activated sludge was confirmed.