This research is an experimental investigation to find the desirable pH of slurry in the desulfurization absorber for a 1000 ㎿ coal fired power plant, operating in compliance with the Air Environmental Conservation Act and the plant's internal regulations. In case the average sulfur dioxide concentration in inflow flue gas, ${\bar{C\;in}}$ [ppm] changed to 500 ppm, 550 ppm, 600 ppm and 635 ppm after fixing inflow flue gas flow rate, generator output, pressure drop in the absorber, and oxidation air flow rate, the desirable pH of the slurry in the absorber, was 5.0, 5.2, 5.3 and 5.4. Thus, it is recommended that the desirable pH of slurry is calculated using the correlation equation, $RpH=0.0018{\times}{\bar{C\;in}}+4,2031$ when the average sulfur dioxide concentration in the inflow flue gas is in the range of 500 ppm to 635 ppm.
Keywords
flue gas desulfurization, FGD; absorber; sulfur oxides, SOx; limestone slurry pH;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kyoung-Jin Hong of Department of Atmospheric Environment Policy, Ministry of Environment, 2017, Notice for Planned to Strengthen the Enforcement Rule of Air Environmental Conservation Act, Ministry of Environment, Press Releases on October 27, 2017.
2 Minister of Environment, 2018, the Air Environmental Conservation Act, Article 16 Clause 1, Enforcement Rule Article 15 and Annex 8, Minister of Environment
3 Korea Power Learning Institute, 2016, Practical Knowledge on Flue Gas Desulfurization System, Korea Power Learning Institute, pp. 45.
4 Jeong-you Kim, 2008, Desulfurization Character- istics for Anthracite Coal Power Plant by Increa- sing Bituminous Coal Fuel, Hanyang University master's thesis, pp. 6.
5 STXHI, 2016, Operation Manual 1 for Dangjin Power Plant No. 9&10, STXHI, pp. 66-101.
6 Binlin Dou, Weiguo Pan, Qiang Jin, Wenhuan Wang and Yu Li, 2009, Prediction of SO2 Removal Efficiency for Wet Flue Gas Desulfur- ization, Energy Conversion and Management 50, pp. 2547-2553.   DOI
7 STXHI, 2013, Material Balances for Dangjin Power Plant No. 9 & 10, STXHI. pp. 5.