• 제목/요약/키워드: destruction efficiency

검색결과 190건 처리시간 0.02초

$NH_3$와 R22를 사용한 냉동장치의 성능특성 비교 (The Comparison of Performance Characteristics in Refrigeration System using $NH_3$ and R22)

  • 하옥남;이규태;하경수;정송태;김진현;홍성인;윤갑식;김양현;권일욱;이종일
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.377-383
    • /
    • 2006
  • Recently, production and use of Freon substances are restrained due to destruction of ozone layer and grobal warming. In this aspect of environmental problems, the best solution is to use the natural refrigerant such as ammonia. Thus, this study apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 1,500 kPa to 1,600 kPa and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구 (Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process)

  • 엄성현;이승준;고은하;홍기훈;황상연
    • 공업화학
    • /
    • 제32권6호
    • /
    • pp.659-663
    • /
    • 2021
  • 반도체 제조공정에서 발생하는 미세먼지와 질소산화물 동시처리를 위하여 오존산화, 습식중화 및 습식전기집진 기술들을 직접화한 10 CMM급 복합오염물질 제거시스템을 개발하였으며, NOx 제거효율 증대를 위한 공정변수 제어 및 최적화를 진행하였다. 특히, 전원공급장치를 포함한 습식전기집진장치 핵심부품 안정성 평가를 위해 30일 동안의 장기운전도 병행하였다. 오존산화 기반 DeNOx 공정에서 가장 중요한 운전변수인 O3/NO 비율은 1.5 부근에서 최적화하였으며, 습식중화 공정의 운전변수를 최적화하여 중화반응에 의한 제거효율 기여도를 확인하였다.

0.18um CMOS 공정을 이용한 강압형 DC-DC 컨버터 보호회로 구현 및 측정 (Implementation and Measurement of Protection Circuits for Step-down DC-DC Converter Using 0.18um CMOS Process)

  • 송원주;송한정
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.265-271
    • /
    • 2018
  • DC-DC buck converter is a critical building block in the power management integrated circuit (PMIC) architecture for the portable devices such as cellular phone, personal digital assistance (PDA) because of its power efficiency over a wide range of conversion ratio. To ensure a safe operation, avoid unexpected damages and enhance the reliability of the converter, fully-integrated protection circuits such as over voltage protection (OVP), under voltage lock out (UVLO), startup, and thermal shutdown (TSD) blocks are designed. In this paper, these three fully-integrated protection circuit blocks are proposed for use in the DC-DC buck converter. The buck converter with proposed protection blocks is operated with a switching frequency of 1 MHz in continuous conduction mode (CCM). In order to verify the proposed scheme, the buck converter has been designed using a 180 nm CMOS technology. The UVLO circuit is designed to track the input voltage and turns on/off the buck converter when the input voltage is higher/lower than 2.6 V, respectively. The OVP circuit blocks the buck converter's operation when the input voltage is over 3.3 V, thereby preventing the destruction of the devices inside the controller IC. The TSD circuit shuts down the converter's operation when the temperature is over $85^{\circ}C$. In order to verify the proposed scheme, these protection circuits were firstly verified through the simulation in SPICE. The proposed protection circuits were then fabricated and the measured results showed a good matching with the simulation results.

SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해 (Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric)

  • 어준;김일원;박진도;이주영;이학성
    • 공업화학
    • /
    • 제22권3호
    • /
    • pp.249-254
    • /
    • 2011
  • Ferroelectric의 강유전체 소구들을 충전한 원통형의 비열 방전 플라즈마 반응기를 설계 제작하였으며, 강유전체 층방전 구조를 구성하는 평판(20 mm 간격) 금속망 전극 사이에 직경 2.0 mm인 $SrBiTaO_9$ (SBT) 소구들을 위치시키고 고압의 교류 전원을 인가하였다. SBT 소구는 상온($25^{\circ}C$)에서 150, 큐리온도($335^{\circ}C$)에서 500의 유전상수를 가졌다. 플라즈마 반응기에서 오존 생성속도는 거의 인가전압의 증가에 비례하였으며, SBT 소구들이 충전된 경우, 20 kV 이상의 인가전압에서 오존 생성속도는 급격하게 증가하였다. 부코로나 방전에서 오존 생성속도가 정코로나 방전에서의 경우보다 높았다. 그러나 톨루엔 및 메틸렌클로라이드의 분해율은 생성된 오존 농도에 비례하여 증가하지 않았다.

Marked Change in Parameter Level in Patient with Renal Disease

  • Bloh, Anmar Hameed;Obead, Dr. Antesar Rheem;Wahhab, Doaa Nassr
    • 대한화학회지
    • /
    • 제66권2호
    • /
    • pp.92-95
    • /
    • 2022
  • Failure Renal is the function of the kidneys to remove waste products and keep them on the periphery. and minerals for the body. Chronic renal failure is a syndrome characterized by a slow, irreversible deterioration of renal function due to the slow destruction of renal parenchyma. Calcium is one of the important minerals that the body contains in the blood and important tissues, and it has an important role in vital processes such as muscle contraction, nerve impulse conduction, the efficiency of heart muscle work, and blood clotting processes. The aim of the study is to study and compare calcium levels in men and women. It includes studying abnormal levels of calcium that cause many diseases, including chronic renal failure, and studying changes associated with renal failure. The method of this study was conducted on patients with chronic renal failure at Murjan Teaching Hospital in Babylon city during the period. The study included a sample of 70 patients (40 males, 30 females) with chronic renal failure, their ages ranged from 30-65, and 60 (30 males, 30 females) healthy without the disease of the same age. The result was a significant decrease in the number of red and white blood cells, hemoglobin concentration, hematocrit and platelets in patients with chronic renal failure, The result has been showed significant level in enzymes activity for transfer of amine group (alanine amino transferase, aspartate amino transferas) and phosphatase alkaline and also concentration of total bilirubin in patient with compare with healthy, Significantly increases, were found in the concentration of urea, uric acid and creatinine, as well as the concentration of calcium and phosphorous ions in the blood serum of patients compared to healthy controls.

우크라이나 군사정보팀의(Military Intelligence Team) 핀셋작전 분석과 시사점 (Analysis and implications on Ukrainian Military Intelligence Team's Decapitation Operation)

  • 조상근;안드레이;박성준;권범준;서강일;박상혁
    • 문화기술의 융합
    • /
    • 제8권6호
    • /
    • pp.435-439
    • /
    • 2022
  • 2022년 2월 24일, 우크라이나-러시아 전쟁이 발발했다. 이 전쟁에서 특이한 현상들이 발생하고 있는데, 그중에 하나가 2차 세계대전 이후 장군들의 전사율이 가장 높다는 것이다. 이것은 우크라이나군이 러시아군의 장군들만을 제거하는 핀셋작전을 전개하고 있기 때문이다. 이를 위해, 우크라이나군은 군사정보팀이라는 특수작전 부대를 운용하고 있는데, 이들은 자체, 미군·나토군, 민간 등의 자산을 융복합하여 다영역에서 활용함으로써 시너지를 창출하고 있다. 특히, 이들은 스타링크를 활용하여 '감시-결심-타격' 활동을 실시간 초연결함으로써 생존성과 작전효용성을 극대화하고 있다. 한국군 또한 다양한 특수작전부대를 보유하고 있고, 한반도에는 대량살상무기 위협이 내재되어 있다. 따라서 우크라이나군에서 운용하는 군사정보팀의 조직편성, 무기체계 및 운용 방법은 한국군이 미래 위협을 상쇄하는데 방향성을 제공할 수 있다.

VOCs 산화반응에서 Pt 촉매에 대한 조촉매의 영향 (Effect of promoter on platinum catalyst for oxidation of VOCs)

  • 김문찬;신진실
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.422-432
    • /
    • 2006
  • VOC는 대기오염의 주원인으로서 인식되어왔다. 촉매산화는 저온에서 높은 효율을 나타내기 때문에 VOCs 제거를 위한 가장 중요한 처리기술중 하나이다. 이 연구에서는 ${\gamma}-Al_2O_3$ 담체에 Pt, Pt-Ru 그리고 Pt-Ir을 담시지켜 촉매를 제조하였다. 반응물로서 Xylene, toluene 그리고 MEK를 사용하였다. 단일 또는 두 가지 이상의 촉매들은 함침법에 의해 준비하였고, XRD, XPS, TEM, BET 분석을 통하여 특성화하였다. 그 결과 Pt-Ru, Pt-Ir 촉매는 Pt 촉매에 비해 더 높은 전환율을 나타내었다. ${\gamma}-Al_2O_3$ 담체상에서 Pt-Ir 촉매가 가장 높은 전환율을 보인다. VOCs산화에서, Pt-Ru, Pt-Ir 촉매는 다양한 활성점을 나타내었고 그것은 Pt의 metal 영역를 강화시켰다. 따라서 두 가지 금속으로 이루어진 촉매가 단일 금속으로 이루어진 촉매에 비해 VOCs 전환율이 더 높았다. 이 연구에서 Pt에 소량의 Ru, Ir 첨가는 VOCs의 산화반응을 증진시켰다.

Design of BOG re-liquefaction system of 20,000 m3 liquid hydrogen carrier

  • Byeongchang Byeon;Hwalong You;Dongmin Kim;Keun Tae Lee;Mo Se Kim;Gi Dock Kim;Jung Hun Kim;Sang Yoon Lee;Deuk Yong Koh
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.49-55
    • /
    • 2023
  • This paper presents the design of a re-liquefaction system as a BOG (boil-off gas) handling process in liquid hydrogen transport vessels. The total capacity of the re-liquefaction system was assumed to be 3 ton/day, with a BOR (boil-off rate) of 0.2 %/day inside the cargo. The re-liquefaction cycle was devised using the He-Brayton Cycle, incorporating considerations of BOG capacity and operational stability. The primary components of the system, such as compressors, expanders, and heat exchangers, were selected to meet domestically available specifications. Case studies were conducted based on the specifications of the components to determine the optimal design parameters for the re-liquefaction system. This encompassed variables such as helium mass flow rate, the number of compressors, compressor inlet pressure and compression ratio, as well as the quantity and composition of expanders. Additionally, an analysis of exergy destruction and exergy efficiency was carried out for the components within the system. Remarkably, while previous design studies of BOG re-liquefaction systems for liquid hydrogen vessels were confined to theoretical and analytical realms, this research distinguishes itself by accounting for practical implementation through equipment and system design.

정수처리공정에서 조류유래 유기물질의 제거 (Removal of Algogenic Organic Matter in Drinking Water Treatment Process)

  • 박세진;차일권;윤태일
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.377-384
    • /
    • 2005
  • 조류는 호소의 부영양화 현상을 발생시킬 뿐 아니라 전반적인 정수처리공정에 많은 문제를 야기 시키고 있다. 그 중에서도 조류 세포와 조류유래 유기물질(Algogenic Organic Matter; AOM)은 휴믹물질처럼 염소 소독 시 유해성 물질인 소독부산물질(Disinfection By-Products; DBPs)을 형성하는 전구물질이다. 본 연구는 전 염소처리와 응집공정에 의한 조류유래 유기물질의 제거특성 변화를 확인하였으며, 또한 부영양화된 호소수 처리 공정으로 철(III)을 이용한 고도응집공정과 UV산화 공정의 적용성을 평가하였다. 전 염소처리공정은 조류제거에는 효과적이지만 수중의 DOC(Dissoluble Organic Carbon)농도와 TMHs(Trihalomethanes) 생성량을 증가시켰다. 응집실험에서는 응집 반응 pH가 조류유래 유기물질과 소독부산물질 제거에 있어 중요한 인자로 작용하였으며, 중성 pH에서 보다 낮은 반응 pH 5에서 DOC, THMs 제거율이 각각 50%와 28% 향상되었다 조류유래 유기물질과 THMs제거에 있어 UV 산화 공정을 적용한 결과, $UV/H_2O_2/Fe^{3+}$ 공정이 가장 효과적이었지만, 반응 pH를 조정한 고도응집공정보다는 효과적이지 않았다.

Anaerobic Filter에 의한 양돈폐수의 전처리 특성 평가 (Evaluation of Swine Wastewater Pretreatment Using Anaerobic Filter)

  • 강호;문서연
    • 대한환경공학회지
    • /
    • 제37권7호
    • /
    • pp.418-425
    • /
    • 2015
  • 본 논문에서는 양돈폐수의 전처리 공정으로 부유성 세라믹 담체로 충진한 Anaerobic Filter (AF)을 이용하여 신재생에너지 메탄가스의 생산 가능성과 전처리 후 유출수의 후속 고도처리 적정성을 평가하였다. 유입 COD 농도가 14,000 mg/L인 양돈폐수를 Anaerobic Filter에 점진적으로 유기물부하(OLR)를 증가시키면서 혹은 수리학적 체류시간을 짧게 유지하면서 $35^{\circ}C$에서 운전한 결과는 다음과 같다. Anaerobic Filter는 HRT 0.5일(OLR 28 g TVS/L-d)에서 최대 메탄발생량 1.74 v/v-d를 달성하였으며, Biogas 기준 TVS 제거효율은 HRT 3일(OLR 4.67 g TVS/L-d)로 운전하였을 때 63%를 얻었다. 반면 유출수 분석에 의한 TCOD 제거효율은 75%를 상회하였다. 유출수의 알카리도는 모든 운전 조건에서 2,050~2,980 mg/L as $CaCO_3$로서 후속 질소제거 시 야기될 수 있는 알카리도 파괴를 상쇄할 수 있을 것이다. HRT 2일 이하의 운전조건에서 Anaerobic Filter 유출수의 COD/TKN 비는 10~35 범위로서 고도처리 시 적정비인 8 이상을 만족하였으며 COD/TP 비는 38~56범위로서 적정비 33 이상 유지가 가능하였다.