• Title/Summary/Keyword: desired image

Search Result 393, Processing Time 0.029 seconds

Automating the visual classification of metal cores

  • Park, In-Gyu;Song, Kyung-Ho;Ha, Tae-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.945-950
    • /
    • 1990
  • An automatic visual classification system is introduced which provides for measuring the length and diameter of coilform cores and dividing them into 5 different classed in terms of how far their length be from the desired length. This task is fully automated by controlling two STEP motors and by using image processing techniques. The classification procedure is broken into three logical parts, First, cores in the form of randomly stacked bundle are lined up one by one so as to be well captured by a camera. The second part involves capturing core image. Then, it enters the measuring process. Finally, this machine would retain all the information relating to the length. According to the final result, cores are sent to the corresponding bin. This considerably simplifies the selecting task and facilitates a greatly improved reliablity in precision. The average classifying capability is about 2 pieces per second.

  • PDF

Automating the visual classification of metal cores (철분 코아(core) 자동 선별기)

  • 박인규;송경호;하태중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.302-307
    • /
    • 1990
  • An automatic visual classification system is introduced which provides for measuring the length and diameter of coilform cores and dividing them into 5 different classes in terms of how far their length be from the desired length. This task is fully automated by controlling two STEP motors and by using image processing techniques. The classification procedure is broken into three logical parts. Fist, cores in the form of randomly stacked bundle are lined up one by one so as to be well captured by a cameras. The second part involves capturing core image. Then, it enters the measuring process. Finally, this machine would retain all tire information relating to the length. According to the final result, cores are sent to the corresponding bin. This considerably simplifies the selecting task and facilitates a greatly improved reliability in precision. The average classifying capability about 2 pieces per second.

  • PDF

Pose alignment control of robot using polygonal approximated gripper images (다각 근사화된 그리퍼 영상을 이용한 로봇의 위치 정렬)

  • Park, Kwang-Ho;Kim, Nam-Seong;Kee, Seok-Ho;Kee, Chang-Doo
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.559-563
    • /
    • 2000
  • In this paper we describe a method for aligning a robot gripper using image information. The region of gripper is represented from HSI color model that has major advantage of brightness independence. In order to extract the feature points for vision based position control, we find the corners of gripper shape using polygonal approximation method which determines the segment size and curvature of each points. We apply the vision based scheme to the task of alignment of gripper to reach the desired position by 2 RGB cameras. Experiments are carried out to exhibit the effectiveness of vision based control using feature points from polygonal approximation of gripper.

  • PDF

A Study on the automatic Lane keeping control method of a vehicle based upon a perception net (퍼셉션 넷에 기반한 차량의 자동 차선 위치 제어에 관한 연구)

  • 부광석;정문영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.257-257
    • /
    • 2000
  • The objective of this research is to monitor and control the vehicle motion in order to remove out the existing safety risk based upon the human-machine cooperative vehicle control. A predictive control method is proposed to control the steering wheel of the vehicle to keep the lane. Desired angle of the steering wheel to control the vehicle motion could be calculated based upon vehicle dynamics, current and estimated pose of the vehicle every sample steps. The vehicle pose and the road curvature were calculated by geometrically fusing sensor data from camera image, tachometer and steering wheel encoder though the Perception Net, where not only the state variables, but also the corresponding uncertainties were propagated in forward and backward direction in such a way to satisfy the given constraint condition, maintain consistency, reduce the uncertainties, and guarantee robustness. A series of experiments was conducted to evaluate the control performance, in which a car Like robot was utilized to quit unwanted safety problem. As the results, the robot was keeping very well a given lane with arbitrary shape at moderate speed.

  • PDF

A measurement of Cardio thoracic ratio by Digital Image processing (디지털 영상처리기법에 의한 심흉곽 계수측정)

  • Yoo, Dong-Joo;Kim, Hong-Ho;Huh, Wong;Hong, Seung-Hong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.23-26
    • /
    • 1989
  • This paper describes the automatic recognition technique for heart enlargement diagnosis with the chest X-ray films enhanced by digital image processing. The technique measures a maximum transverse of the daiphragm and a maximum transverse of the heart by means of direction signature algorithms, then calculates the desired ratio of these two measured values. This is often refered to a cadiothoracic ratio which gives as useful clue for heart enlargement symptom. The experiment results in this paper show presented method is more efficient than the manual diagnosis method of the symptom.

  • PDF

Effects of Channel Errors on Transform-Coded Image Signals (변환부호화된 영상신호에 대한 채널 오류의 영향)

  • 백종기;문상재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.3
    • /
    • pp.216-223
    • /
    • 1987
  • This paper presents an analysis of the effects of statistically independent channel errors on the mean-squared error performance of image transform coding systems. The analysis is discussed for several different stochasic statistics of the quantizer input valuse. The stochastic distributions under consideration here are Laplacian, Gaussian and uniform. For each case of the distributions, we evaluate the MSE performance when NBC, FBC, MDC and Gray code respectively is employed for encoding the quantized values of the transformed coeffecients into the corresponding code words. The result of this study shows that what code is desired to be chosen to minimize the MSE for the given stochastic distributions of the quantizer input values.

  • PDF

A Scheme Tracking a Moving Object for Biped Robot (이족로봇을 이용한 이동물체 추적 기법)

  • Park, Sang-Bum;Lee, Boo-Hyung;Han, Young-Joon;Hahn, Hern-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.839-840
    • /
    • 2006
  • Our paper proposes a novel moving object tracking scheme for biped robot using a single camera. For walking control of a biped robot we analyze the dynamics of a three-dimensional inverted pendulum model. This analysis leads us a simple linear dynamics. And, the control parameter of the biped robot is derived from the feedback signal which converges the position of a image feature to the feature position of a desired image and the feedforward signal which compensates the motion component due to the moving object.

  • PDF

2D Sparse Array Transducer Optimization for 3D Ultrasound Imaging

  • Choi, Jae Hoon;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2014
  • A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

Squaring the Circle in Perspective (방원도의 투영)

  • Kim, Hong-Jong
    • Journal for History of Mathematics
    • /
    • v.27 no.6
    • /
    • pp.395-402
    • /
    • 2014
  • When the circle inscribed in a square is projected to a picture plane, one sees, in general, an ellipse in a convex quadrilateral. This ellipse is poorly described in the works of Alberti and Durer. There are one parameter family of ellipses inscribed in a convex quadrilateral. Among them only one ellipse is the perspective image of the circle inscribed in the square. We call this ellipse "the projected ellipse." One can easily find the four tangential points of the projected ellipse and the quadrilateral. Then we show how to find the center of the projected ellipse. Finally, we describe a pair of conjugate vectors for the projected ellipse, which finishes the construction of the desired ellipse. Using this algorithm, one can draw the perspective image of the squared-circle tiling.

Effect of Corrosion Conditions on the Luster Change of Metallic Yarns and Fabric - Analysis of Changes in Reflection and Transmission -

  • Shin, Hye-Sun;Kim, Jong-Jun;Jeon, Dong-Won
    • Journal of Fashion Business
    • /
    • v.12 no.3
    • /
    • pp.54-61
    • /
    • 2008
  • The glitter of lame fabrics containing the metallic yarns may further be altered by $Na_2CO_3$ aqueous solution at an elevated temperature. In this study, the effect of the corrosion treatment on the yarn luster was evaluated using image analysis. The alkaline solution treatment was found to be more effective on the aluminum-based specimens than on the silver-based specimens. It was found that corrosion percentage measurement based on the transmission analysis may provide reasonable quantitative index, even if the measurement relies on an indirect method. Based on the quantitative results, the alkaline treatment condition for the specific specimen would be optimized for a desired glitter modification.