• Title/Summary/Keyword: design of the experiments

Search Result 6,486, Processing Time 0.046 seconds

Effect of pore-water salinity on freezing rate in application of rapid artificial ground freezing to deep subsea tunnel: concentration of laboratory freezing chamber test (고수압 해저터널에 급속 인공동결공법 적용시 간극수의 염분 농도가 동결속도에 미치는 영향 평가: 실내 동결챔버시험 위주로)

  • Oh, Mintaek;Lee, Dongseop;Son, Young-Jin;Lee, In-Mo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.401-412
    • /
    • 2016
  • It is extremely difficult to apply conventional grouting methods to subsea tunnelling construction in the high water pressure condition. In such a condition, the rapid artificial freezing method can be an alternative to grouting to form a watertight zone around freezing pipes. For a proper design of the artificial freezing method, the influence of salinity on the freezing process has to be considered. However, there are few domestic tunnel construction that adopted the artificial freezing method, and influential factors on the freezing of the soil are not clearly identified. In this paper, a series of laboratory experiments were performed to identify the physical characteristics of frozen soil. Thermal conductivity of the frozen and unfrozen soil samples was measured through the thermal sensor adopting transient hot-wire method. Moreover, a lab-scale freezing chamber was devised to simulate freezing process of silica sand with consideration of the salinity of pore-water. The temperature in the silica sand sample was measured during the freezing process to evaluate the effect of pore-water salinity on the frozen rate that is one of the key parameters in designing the artificial freezing method in subsea tunnelling. In case of unfrozen soil, the soil samples saturated with fresh water (salinity of 0%) and brine water (salinity of 3.5%) showed a similar value of thermal conductivity. However, the frozen soil sample saturated with brine water led to the thermal conductivity notably higher than that of fresh water, which corresponds to the fact that the freezing rate of brine water was greater than that of fresh water in the freezing chamber test.

Development and Evaluation of an Educational Program for the Clothing life Domain in Home Economics through a Theme-Based Integrated Approach (주제 중심 통합적 접근에 의한 가정 교과 의생활 영역 교육 프로그램 개발과 평가 - "의복관리"와 "섬유(재료)" 주제를 중심으로 -)

  • Kim, Nam-Eun;Lee, Hye-Ja
    • Journal of Korean Home Economics Education Association
    • /
    • v.22 no.3
    • /
    • pp.163-188
    • /
    • 2010
  • This study set out to develop and evaluate an educational program for the Clothing Life of Home Economics through the theme-based integrated approach develop integrated thinking abilities for solving everyday problems. For those purposes, it selected a couple of themes in the area of Clothing Life toward which the theme-based integrated approach could be develop and evaluate an educational program. The developed program was applied and assessed in total 28 hours of field lessons given to eighth graders attending B Middle School in Busan Metropolitan City. The analysis stage involved an exploration into programs related to an integrated approach to other subjects; the design stage identification of program types; and the development stage theme selection according to the selection criteria. The previous studies were analyzed along with the Technology and Home Economics textbooks to select a theme. two themes "Clothing Management" and "Fabrics(Materials)" were selected after discussing with the students on the Messenger and with a group of experts. Then content was organized and composed around the themes by discussing connections with other subjects. There were three evaluation; one by experts, another through preliminary lessons, and the other through field lessons. Following the research procedure, a theme-based integrated program was developed for the two selected themes. It contained total 49 and 32 learning materials for "Clothing Management" and "Fabrics(Materials)," respectively. Those learning materials were comprised of experiments and practices according to the nature of the themes. Each program consisted of the goals, learning content, content organization chart, learning activities, and evaluation; learning activities experiences, practice and experiment activities, self-directed activities and problem-solving processes; and evaluations self-evaluation, teacher evaluation, peer evaluation, portfolio, and experiment reports. The program was assessed three times. The first and second evaluation results found that the program was well compatible with the current needs, was properly organized to give lessons through integration with other subjects, and continuously maintained the students' interest. They, however, requested that there should be detailed explanations about each part of the program content. In the third evaluation done by the students during field lessons, 60% of them said that the program was fun and its content was easy to understand, that they realized a theme could be connected to several other subjects, and that the program could be applied to actual life. The educational program through the theme-based integrated approach is significant in that it is an educational program for the area of Clothing Life and tries an integrated approach. It helped the students not only gather knowledge in an integrated manner, but put it to practical uses to solve various problems they faced in actual life by creatively changing integrated knowledge. The study will be hopefully used by many teachers so that the students solve problems based on the ability of integrating various knowledges organically.

  • PDF

Estimation of Rice Grain Protein Contents Using Ground Optical Remote Sensors (지상광학센서를 이용한 쌀 단백질함량 예측)

  • Kim, Yi-Hyun;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.551-558
    • /
    • 2008
  • It is well known that the protein content of rice grain is an indicator of taste of cooked rice in the countries where people as the staple food. Ground-based optical sensing over the crop canopy would provide information not only on the mass of plant body which reflects the light, but also on the crop nitrogen content which is closely related to the greenness of plant leaves. The vegetation index has been related to crop variables such as biomass, leaf nitrogen, plant cover, and chlorophyll in cereals. The objective of this study was to investigate the correlation between GNDVI and NDVI values, and grain protein content at different dates and to estimate the grain protein content using G(NDVI) values. We measured Green normalized difference vegetation index [$GNDVI=({\rho}0.80{\mu}m-{\rho}0.55{\mu}m)/({\rho}0.80{\mu}m+{\rho}0.55{\mu}m)$] and [$GNDVI=({\rho}0.80{\mu}m-{\rho}0.68{\mu}m)/({\rho}0.80{\mu}m+{\rho}0.68{\mu}m)$] by using two different active sensors. The study was conducted during the rice growing season for three years from 2005 through 2007 at the experimental plots of National Institute of Agricultural Science and Technology. The experiments were carried out by randomized complete block design with the application of four levels of nitrogen fertilizers(0, 70, 100, 130kg N/ha) and the same amount of phosphorous and potassium content of the fertilizers. After heading stage, relationships between GNDVI of rice canopy and grain protein content showed the highly positive correlation at different dates for three years. GNDVI values showed higher correlation coefficients than that of NDVI during growing season in 2005-07. The correlation between GNDVI values at different dates and grain protein contents was highly correlated at early July. We attempted to estimate the grain protein content at harvesting stage using GNDVI values from early July for three years. The determination coefficients of the linear model by GNDVI values were 0.9l and the measured and estimated grain protein content at harvesting stage using GNDVI values highly correlated($R^2=0.96^{***}$). Results from this study show that GNDVI appeared very effective to estimate leaf nitrogen and grain protein content of rice canopy.

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.

Odysseus/Parallel-OOSQL: A Parallel Search Engine using the Odysseus DBMS Tightly-Coupled with IR Capability (오디세우스/Parallel-OOSQL: 오디세우스 정보검색용 밀결합 DBMS를 사용한 병렬 정보 검색 엔진)

  • Ryu, Jae-Joon;Whang, Kyu-Young;Lee, Jae-Gil;Kwon, Hyuk-Yoon;Kim, Yi-Reun;Heo, Jun-Suk;Lee, Ki-Hoon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.4
    • /
    • pp.412-429
    • /
    • 2008
  • As the amount of electronic documents increases rapidly with the growth of the Internet, a parallel search engine capable of handling a large number of documents are becoming ever important. To implement a parallel search engine, we need to partition the inverted index and search through the partitioned index in parallel. There are two methods of partitioning the inverted index: 1) document-identifier based partitioning and 2) keyword-identifier based partitioning. However, each method alone has the following drawbacks. The former is convenient in inserting documents and has high throughput, but has poor performance for top h query processing. The latter has good performance for top-k query processing, but is inconvenient in inserting documents and has low throughput. In this paper, we propose a hybrid partitioning method to compensate for the drawback of each method. We design and implement a parallel search engine that supports the hybrid partitioning method using the Odysseus DBMS tightly coupled with information retrieval capability. We first introduce the architecture of the parallel search engine-Odysseus/parallel-OOSQL. We then show the effectiveness of the proposed system through systematic experiments. The experimental results show that the query processing time of the document-identifier based partitioning method is approximately inversely proportional to the number of blocks in the partition of the inverted index. The results also show that the keyword-identifier based partitioning method has good performance in top-k query processing. The proposed parallel search engine can be optimized for performance by customizing the methods of partitioning the inverted index according to the application environment. The Odysseus/parallel OOSQL parallel search engine is capable of indexing, storing, and querying 100 million web documents per node or tens of billions of web documents for the entire system.

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

Studies on the Environmentally and Ecologically Stable Revegetation Measures on Rock Cut-Slopes - Availability of Forest Topsoil as a Hydroseeding Material in Greenhouse Experiment - (암절취(岩切取) 훼손(毁損)비탈면에 대한 환경생태적(環境生態的)으로 안정(安定)된 녹화공법(綠化工法)에 관(關)한 연구(硏究)(I) -산림표층토(山林表層土)를 이용(利用)한 녹화토(綠化土)의 효능분석(效能分析)을 위한 실내실험(室內實驗)-)

  • Woo, Bo-Myeong;Kim, Kyung-Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.308-315
    • /
    • 1998
  • This study was conducted to evaluate the availability of the forest topsoil as a source of the "Native-soil(seed-fertilizer-soil materials)" for the hydroseeding measures which are environmentally and ecologically stable revegetation measures on rock cut-slopes. Soil sampling and factorial experiments were used with a split plot design(main plot : forest soil type and soil spraying thickness, subplot : seeding rate) in 1996. Results obtained in this study were summarized as follows : Because of the competition between the seeded(introduced) species and the native species, the number of naturally emerged species in the non-seeded plot and that of in the seeded plot were $5{\sim}9species/0.07m^2$ and $2{\sim}6species/0.07m^2$, respectively. As increasing the seeding rate(introduced species), the appearance ratio of naturally emerged species was decreased. The total number of individuals was high in the plot which used coniferous forest soil as a seed source, however the ratio of the individuals of naturally emerged species was high(30%) in the plot which used deciduous forest soil. The usage of the forest topsoil as seed bank source onto the "Native-soil" materials for hydroseeding could be reduce the seeding rate to $1,000seedlings/m^2$. According to the several factors which are competition between seeded species and naturally emerged species, dryness of soil materials, and seed burial, spraying thickness with more than 5cm was suitable for the growth of plants in variety.

  • PDF

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

Supercritical Water Oxidation of Anionic Exchange Resin (초임계수 산화를 이용한 음이온교환수지 분해)

  • Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe;Kim, Kyeong-Sook;Son, Soon-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.549-557
    • /
    • 2006
  • The characteristics of supercritical water oxidation have been studied to decompose the waste anionic exchange resins which were produced from a power plant. The waste resins from a power plant were mixture of anionic and cationic exchange resins. The waste anionic exchange resins had been separated from the waste resins using a solid-liquid fluidized bed. It was confirmed that the cationic exchange resins were not included in the separated anionic exchange resins by the elemental and thermogravimetric analysis. A slurry of anionic exchange resins which could be fed continuously to a supercritical water oxidation apparatus by a high pressure pump was prepared using a wet ball mill. Although the COD of liquid effluent had been reduced more than 99.9% at 25.0 MPa and $500^{\circ}C$ within 2 min, the total nitrogen content was reduced only 41%. The addition of nitric acid to the slurry could reduce the total nitrogen content in treated water. The central composite design as a statistical desist of experiments had been applied to optimize the conditions of decomposing anionic resin slurry by means of the COD and total nitrogen contents in treated waters as the key process output variables. The COD values of treated waters had been reduced sufficiently to $99.9{\sim}100%$ af the reaction conditions of $500{\sim}540^{\circ}C$, 25.0 MPa within 2 min. The effects of temperature and nitric acid concentration on COD were not significant. However, the effect of nitric acid concentration on the total nitrogen was found to be significant. The regression equation for the total nitrogen had been obtained with nitric acid concentration and the coefficient of determination($r^2$) was 95.8%.