건축물의 성능적 내화설계 평가 요소기술 개발 (Development of the Evaluation Element for Fire Engineering Design)

  • 권인규;김흥열
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.410-414
    • /
    • 2009
  • Performance based fire engineering design should be developed through basic survey and fundamental element such as analytic program for evaluation of fire performance of building. The basic elements will be expressed to the surveys of the structures of building laws, regulation and the fundamental elements consist of technical guidances contained design fires, heat analysis, determination of structural performance.

  • PDF

Simulating the Response of a 10-Storey Steel-Framed Building under Spreading Multi-Compartment Fires

  • Jiang, Jian;Zhang, Chao
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.389-396
    • /
    • 2018
  • This paper presents a numerical investigation on the structural response of a multi-story building subjected to spreading multi-compartment fires. A recently proposed simple fire model has been used to simulate two spreading multi-compartment fire scenarios in a 10-story steel-framed office building. By assuming simple temperature rising and distribution profiles in the fire exposed structural components (steel beams, steel column and concrete slabs), finite element simulations using a three-dimensional structural model has been carried out to study the failure behavior of the whole structure in two multi-compartment fire conditions and also in a standard fire condition. The structure survived the standard fire but failed in the multi-compartment fire. Whilst more accurate fire models and heat transfer models are needed to better predict the behaviors of structures in realistic fires, the current study based on very simple models has demonstrated the importance and necessity of considering spreadingmulti-compartment fires in fire resistance design of multi-story buildings.

주거시설의 화재통계를 이용한 화재안전설계를 위한 기초적 연구 (A Basic Study on the Safety Design using the Fire Statistics of Residential Facilities)

  • 윤웅기;서동구;김동은;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2013
  • A study on the fire scenario proposal of residential facilities by using fire statistics. as a result of analyzing residential facilities fires by using fire statistics of national emergency management agency during 2007~2012, fires from carelessness were the most causes. specially, fires during food cooking among carelessness showed the highest occurrence frequency, and followed sparks, neglecting fire sources, and cigarette stubs in order. through this the study suggested fire scenarios according, It is believed that can be used as basic data for applying a secure building in a fire using a basis for fire safety design of buildings in the future this.

  • PDF

고층건물 화재시 배연계획에 관한 연구 (A Study on the Smoke Venting Plan in the High-Rise Building Fires)

  • 김우영
    • 한국화재소방학회논문지
    • /
    • 제3권1호
    • /
    • pp.11-18
    • /
    • 1989
  • The suffering damage of persons and properties from fires has become large sized in modem society that buildings are rapidly higher, denser and more complex. Especially, in the building fires, it is recently the most important issue that the treatment of smoke which is the hardest hindrance in escape. Therefore, as effective exhaust matter of smoke or poisonous gas is connected directly, synthetic, fundamental fire prevention countermeasure must be achieved after mutual connections between architecture and mechanical system and requlations ars sufficiently examinated. From this studies, 1 show the structure computation data which can be applied to smoke venting plan and architectural design for safety after find necessity and point at issue of prevention plan of fires by examinating statistical data about cause and damage situation.

  • PDF

전기화재 감소를 위한 아크차단기의 필요성 및 마이컴 설계 알고리즘 연구 (A Study on Necessity of AFCI and Algorithm of Micom Design for Electric Fire Reduction)

  • 이해건;곽동걸;박근영;이봉섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.491-492
    • /
    • 2017
  • Despite the numerous electric systems that have been developed, electric fires remain at a similar rate each year in total fires. This paper suggests that it is not enough to prevent electric fires only by the currently used electric system. We have studied ways to improve this situation. we have focused on AFCIs that have already been institutionalized in the United States. AFCIs work by detecting the arc fault in the circuit. This is expected to contribute greatly to reducing electric fires.

  • PDF

우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구 (A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design)

  • 이강훈
    • 한국화재소방학회논문지
    • /
    • 제4권2호
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

Flammability and Multi-objective Performance of Building Façades: Towards Optimum Design

  • Bonner, Matthew;Rein, Guillermo
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.363-374
    • /
    • 2018
  • The façade is an important, complex, and costly part of a building, performing multiple objectives of value to the occupants, like protecting from wind, rain, sunlight, heat, cold, and sound. But the frequency of façade fires in large buildings is alarming, and has multiplied by seven times worldwide over the last three decades, to a current rate of 4.8 fires per year. High-performing polymer based materials allow for a significant improvement across several objectives of a facade (e.g., thermal insulation, weight, and construction time) thereby increasing the quality of a building. However, all polymers are flammable to some degree. If this safety problem is to be tackled effectively, then it is essential to understand how different materials, and the façade as a whole, perform in the event of a fire. This paper discusses the drivers for flammability in facades, the interaction of facade materials, and current gaps in knowledge. In doing so, it aims to provide an introduction to the field of façade fires, and to show that because of the drive for thermal efficiency and sustainability, façade systems have become more complex over time, and they have also become more flammable. We discuss the importance of quantifying the flammability of different façade systems, but highlight that it is currently impossible to do so, which hinders research progress. We finish by putting forward an integral framework of design that uses multi-objective optimization to ensure that flammability is minimized while considering other objectives, such as maximizing thermal performance or minimizing weight.

A Review and Analysis of the Thermal Exposure in Large Compartment Fire Experiments

  • Gupta, Vinny;Hidalgo, Juan P.;Lange, David;Cowlard, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.345-364
    • /
    • 2021
  • Developments in the understanding of fire behaviour for large open-plan spaces typical of tall buildings have been greatly outpaced by the rate at which these buildings are being constructed and their characteristics changed. Numerous high-profile fire-induced failures have highlighted the inadequacy of existing tools and standards for fire engineering when applied to highly-optimised modern tall buildings. With the continued increase in height and complexity of tall buildings, the risk to the occupants from fire-induced structural collapse increases, thus understanding the performance of complex structural systems under fire exposure is imperative. Therefore, an accurate representation of the design fire for open-plan compartments is required for the purposes of design. This will allow for knowledge-driven, quantifiable factors of safety to be used in the design of highly optimised modern tall buildings. In this paper, we review the state-of-the-art experimental research on large open-plan compartment fires from the past three decades. We have assimilated results collected from 37 large-scale compartment fire experiments of the open-plan type conducted from 1993 to 2019, covering a range of compartment and fuel characteristics. Spatial and temporal distributions of the heat fluxes imposed on compartment ceilings are estimated from the data. The complexity of the compartment fire dynamics is highlighted by the large differences in the data collected, which currently complicates the development of engineering tools based on physical models. Despite the large variability, this analysis shows that the orders of magnitude of the thermal exposure are defined by the ratio of flame spread and burnout front velocities (VS / VBO), which enables the grouping of open-plan compartment fires into three distinct modes of fire spread. Each mode is found to exhibit a characteristic order of magnitude and temporal distribution of thermal exposure. The results show that the magnitude of the thermal exposure for each mode are not consistent with existing performance-based design models, nevertheless, our analysis offers a new pathway for defining thermal exposure from realistic fire scenarios in large open-plan compartments.

구획실 내 액체 풀화재에 대한 디자인 화재곡선 적용 연구 (Application Study of Design Fire Curves for Liquid Pool Fires in a Compartment)

  • 백빛나;오창보;이의주;남동군
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.43-51
    • /
    • 2017
  • 본 연구에서는 화재 수치계산에 사용하기 위한 새로운 디자인 화재곡선을 제안하였다. ISO 9705 구획실 내 형성된 옥탄과 헵탄연료 풀화재에 대해 기존에 제안된 2차곡선과 지수함수 형태의 디자인 화재곡선과 새롭게 제안된 디자인 화재곡선을 적용한 Fire Dynamics Simulator (FDS) 수치계산을 수행하였다. 여기서 얻어진 수치계산 결과와 실험에서 측정한 온도와 $O_2$, $CO_2$ 변화와 비교하여 디자인 화재곡선의 예측성능을 평가하였다. FDS 계산과 실험결과의 비교를 통해 2차곡선과 지수함수 형태의 디자인 화재곡선을 적용했을 때는 측정된 온도보다도 훨씬 완만하게 증가하고 감소하는 것을 알 수 있었다. 그러나 새로 제안한 2가지 디자인 화재곡선은 기존 디자인 화재곡선보다는 급격히 상승하여 실험결과에 좀 더 유사하게 나타나는 것으로 확인되어 실용적 관점에서 수치계산에 활용될 수 있음을 확인하였다.

The Design and Implementation of Mobile Application Solution for Forest Fire based on Drone Photography and Amazon Web Service (AWS)

  • Choi, Si-eun;Bang, Jong-ho
    • 인터넷정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.31-37
    • /
    • 2020
  • Last year's Goseong-Sokcho forest fires have highlighted the limitations of extinguishing work for night-time forest fire and the importance of quick identification for information on the spread of forest fire. However, it is not easy to find services that take into account the characteristics of forest fires, as most existing disaster-related mobile applications and research assume various disaster situations rather than just forest fire situations. Therefore, a system that can provide information quickly is needed, taking into account the characteristics of forest fires and the limitations of extinguishing work. In this paper, we propose evacuation route guidance services that bypass areas where fire has already spread, supplement existing methods of extinguishing work, and provide general information on forest fire situations in real time, by putting drones into forest fire situations. It has been implemented to automate image analysis using the Rekognition service of Amazon Web Service (AWS), and the results of fire detection and the T Map API guide the evacuation path. It is expected that the results of this paper will allow efficient and rapid rescue and extinguishing work to be carried out, and further reduce the damage of human life caused by forest fires.