• Title/Summary/Keyword: design discharge

Search Result 1,380, Processing Time 0.025 seconds

Off-Line PD Diagnosis for Stator Winding of Rotating Machines Using a UWB Sensor

  • Lwin, Kyaw-Soe;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • We studied partial discharge detection by sensing electromagnetic waves emitted from the partial discharge source in an HV Rotating Machine using a UWB sensor. In this study, we design a new type of compact low frequency UWB sensor based on micro-strip technology. We also perform many experiments of offline and dismantled testing compared with the existing HFCT on stator winding of the HV generator. We mention the detailed design of a new compact UWB sensor along with the time domain PRPD pattern and frequency domain results of partial discharge in the stator winding of a 6.6kV rotating machine by offline testing performed in a laboratory.

Analysis of the Effects of SD Plasma on Aerodynamic Drag Reduction of a High-speed Train

  • Lee, Hyung-Woo;Kwon, Hyeok-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1712-1718
    • /
    • 2014
  • Experimental analysis according to the plasma actuator design variables was performed in order to verify the effects of sliding discharge plasma on aerodynamic drag reduction of a high-speed train. For the study, sliding discharge plasma actuator and high-frequency, high-voltage power supply were developed and experimented to figure out the best design variables for highest ionic wind velocity which could reduce the drag force. And then, 5% reduced-scale model of a high-speed train was built for wind tunnel test to verify it. From the results, it was confirmed that sliding discharge plasma had contribution to reduce the drag force and it had the potential to be applied to real-scale trains.

Analysis of the Dynamic Characteristics of the Underwater Discharge System using a Centrifugal Pump (원심펌프 방식 수중발사 시스템의 동특성 해석)

  • Jung, Chan-Hee;Park, In-Ki
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.594-600
    • /
    • 2012
  • In this study, the mathematical model of the underwater discharge system using a centrifugal pump was derived and the rotating speed profiles of the pump which satisfied the discharge performance requirements were obtained through the underwater discharge simulations. The simulation results showed that the dynamic characteristics of a projectile were greatly affected by the rotational speed of the pump, however, hardly by the discharge depth. It is anticipated that the simulation model can be used to derive the design parameters and analyze the performance concerning the underwater discharge system using a centrifugal pump.

Characteristics of DC Surface Discharge for the Development of UV Camera (자외선 카메라 개발을 위한 직류 연면방전 특성)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.98-103
    • /
    • 2011
  • Recently, UV(ultra-violet rays) camera has attracted a great deal of interest from the view point of easy judgement in inspections and diagnoses of the safety of power equipment. Especilly, UV camera is applied the inspection of UV with corona discharge. One of the most important and difficult problems is the basic research of filter design, materials and corona discharge. In this paper, we will report on the UV generation, corona pulse count and the polarity effect of positive and negative DC surface discharge in air. Also, corona discharge characteristics are analyzed using prototype UV camera of Korea. UV generation and corona pulse count due to surface discharge in positive needle is higher than that of negative needle.

Peak Discharge Change by Dirrerent Design Rainfall on Small Watershed

  • Jun, Byong-Ho;Jang, Suk-Hwan
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.97-104
    • /
    • 1992
  • To design the minor structures in the small watersheds, it is required to calculate the peak discharge. For these calculations the simple peak flow prediction equations, the unit hydrograph method. the syntheic unit hydrograph methods or the runoff simulation models are adopted. To use these methods it is generally requried to know the amount and the distributions of the design rainfall; which are the uniform distribution, the trangular distribution, the trapezoidal distribution, or the Huff type distribution. In this study, the peak discharges are calculated by the different rainfall distributions and the results are compared.

  • PDF

A Study on the Effects of Insulating Material Barrier on the Surface Creepage over Discharge (연면방전의 특성과 절연체의 영향 및 그 응용)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.19 no.2
    • /
    • pp.12-17
    • /
    • 1970
  • In the design of electrical equipment insulation, it is customary to place pressboard and other insulating material at right angle to the electrical discharge path, which is based on the insulation tests performed on equipment under various conditions such as types of insulation, applied voltage and other unique situations. Since electrical equipment manufacturing started only recently, there is a scarcity of available data on insulation problems, which make it difficult for the design engineers. The author untook this study to provide such analytical design data for various conditions based on the experiment conducted on the equipment being manufactured, thus reducing possible errors in the process.

  • PDF

A Study on Hydrologic Analysis and Some Effects of Urbanization on Design Flow of Urban Storm Drainage Systems (1) (도시 하수도망의 수문학적인 평가와 설계확률유량의 점대화 성향에 관한 연구(제1보))

  • 강관원;서병하;윤용남
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.27-34
    • /
    • 1981
  • The design flow of the urban strom drainage systems has been assessed largely on a basis of empirical relations between rainfall and runoff, and the rational formula has been widely used for the cities in our country. In order to estimate it more accurately, the urban runoff simulation model based on the RRl method has been developed and applied to the sample basin in this study. The rainfall hyetograph of the design stromfor the design flow has been obtained by the determination of the total rainfall and the temporal distributions of that rainfall. The total rainfall has been assessed from the empirical formula of rainfall intensity and the temporal distribution of that rainfall determined on the basis of Huff's method from the historical rainfall data of the basin. The virtual inflow hydrograph to each inlet of the basin has been constructed by computing the series of discharges in each time increment, using design strom hyetograph and time-area diagram. The actual runoff hydrograph at the basin outlet has been computed from the virtual inflow hydrographs by developing a relations between discharge and storage for the watershed. The discharge data for verification of the simulated runoff hydrograph are not available in the sample basin and so the sensitivity analysis of the simulation model has not been possible. The peak discharge for the design of drainage systems has been estimated from the computed runoff hydrograph at the basin outlet and compared to thatl obtained form the rational formula.

  • PDF

The Effects of Nursing Information on knowledge, physical symptoms, state anxiety and daily activity levels of patients recovering from open heart surgery (퇴원시 간호정보 제공이 개심술 환자의 지식, 신체증상, 상태불안 및 일상활동에 미치는 효과에 관한 연구)

  • 김금순;유경희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.257-267
    • /
    • 1991
  • This study investigated the effects of nursing in formation given verbally and a booklet on the knowledge, Physical symptoms, anxiety and daily activities of patients recovering from open heart surgery from just before discharge to six weeks after discharge. The convenience sample was of patients who had undergone open heart surgery in Seoul National University Hospital. The first 25 patients who agreed to participate in the study became the control group. They did not receive the intentional information but the usual nursing care. The next 28 patients became the experimental group who received a booklet about their post-discharge care which was discussed with them by the researcher before discharge. This study used a non equivalent control group non - synchronized quasiexperimental design. The tools included a 30 item knowledge scale, a 9 item physical symptom scale, Spielberger's state anxiety scale, and a 28 item daily activity scale. The instruments were applied before discharge and at two and six weeks after discharge. For data analysis, frequency, t-test, Pearson's Correlational Coefficient and Cronbach's $\alpha$ were used. The results were as follows : 1. Information given through the booklet was effective in increasing the knowledge of patients recovering from open heart surgery. The experimental group's knowledge was higher at 2 weeks after discharge than prior to discharge (P<0.05). 2. There was no significant difference in physical symptoms between the two groups at two and six weeks after discharge. 3. Information given through the booklet was effective in decreasing the State Anxiety two weeks after discharge (P<0.001) but at six weeks after discharge, there was no significant difference in anxiety between the control and the experimental groups. 4. There was no significant difference in daily activity between the two groups at two and six weeks after discharge. 5. There was a negative correlation between knowledge at discharge and at 2 weeks and anxiety at 2 weeks after discharge. There was a positive correlation between knowledge at discharge and daily activity at 2 weeks after discharge. There was a negative correlation between knowledge at 2 weeks and Physical symptom at 6 weeks after discharge.

  • PDF

Experimental Investigation of the Development of a Rotor Type Slurry Pump (로터형 슬러리 펌프 개발을 위한 실험적 연구)

  • Park, Sang-Kyoo;Yun, Jae-Geun;Yangr, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.456-462
    • /
    • 2015
  • The objective of this study was to develop an advanced pump technology using tornado and axial pumping principles without priming water. The developed rotor type slurry pump consisted of an electric motor, driving shaft and coupling, a rotor, an impeller, suction and discharge pipes. For the clean water test, the experimental results are presented for the discharge flowrate, electric power input and vacuum pressure with the rotor design parameters as a function of the motor rpm. The slurry discharge characteristics with the solid concentration of the cement slurry was performed. As the rotor diameter and height increase, the discharge flowrate and electric power input increase while the vacuum pressure in the suction pipe decreases. The rotor thickness had no significant effect on the discharge flowrate and electric power input. Slurries with more than 18 % solid concentration, which is the development factor, can be pumped.

Conductive and Mechanical Properties Study of Ti-doped DLC (ta-C:Ti) Film on Semiconductor Probe through Taguchi Bobust Design (다구찌 강건 설계를 통한 반도체 Probe상 Ti 도핑된 DLC(ta-C:Ti) 코팅 막의 전도성 및 기계적 물성 연구)

  • Kim, Do-young;Shin, Jun-ki;Jang, Young-Jun;Kim, Jongkuk
    • Tribology and Lubricants
    • /
    • v.38 no.6
    • /
    • pp.274-280
    • /
    • 2022
  • There is a problem that semiconductor probe pin has a short lifespan. In order to solve this problem, Ti having excellent conductivity was doped to tetrahedral amorphous carbon (ta-C) having excellent hardness and abrasion resistance. This experiment was planned through the Taguchi robust design to determine the effect of the control factor of the ta-C:Ti coating film. The effect and contribution of control factors such as Unbalanced Magnetron Sputter(UBM) discharge current, arc discharge current, temperature, and bias voltage on ta-C:Ti characteristics were analyzed from the perspective of electrical and mechanical characteristics. The UBM discharge current was set to 4, 6, and 8 A. The main control factor of thickness and resistance is the UBM discharge current, and the thickness increased and the resistance decreased as the current increased. The decrease in resistance is due to the increase in the Ti content of the ta-C:Ti coating film. The arc discharge current was set to 60, 80, and 100 A. The main control factor of hardness and wear is the arc discharge current, and as the current rises, the hardness increases and the wear area decreases. This is due to the increased ta-C content of the ta-C:Ti coating film. Since resistance and wear are important for Probe Pin, the optimal level is set from the perspective of resistance and wear and a confirmation experiment is conducted.