INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

Effect of Irradiation on Apoptosis, Cell Cycle Arrest and Calcified Nodule Formation of Rat Calvarial Osteoblast (방사선 조사가 배양된 조골세포의 apoptosis와 세포주기의 변화 및 석회화 결절 형성에 미치는 영향에 관한 연구)

  • Lee Young-Mi;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.189-198
    • /
    • 2000
  • Purpose: The study was aimed to detect the induction of apoptosis, cell cycle arrest and calcified nodule formation after irradiation on primarily cultured osteoblasts. Materials and Methods: Using rat calvarial osteoblasts, the effects of irradiation on apoptosis, cell cycle arrest, and calcified nodule formation were studied. The single irradiation of 10 and 20 Gy was done with 5.38 Gy/min dose rate using the l37Cs cell irradiator at 4th and 14th day of culture. Apoptosis induction and cell cycle arrest were assayed by the flowcytometry at 1, 2, 3, and 4 days after irradiation. The formation of calcified nodules was observed by alizarin red staining at 1, 3, 10, 14 days after irradiation at 4th day of culture, and at 1, 4, 5 days after irradiation at 14th day of culture. Results: Apoptosis was not induced by 10 or 20 Gy independent of irradiation and culture period. Irradiation did not induced G1 arrest in post-irradiated ostedblasts. After irradiation at 4th-day of culture, G2 arrest was induced but it was not statistically significant after irradiation at 14th-day of culture. In the case of irradiated cells at 4th day of culture, calcified nodules were not formed and at 14th-day of culture after irradiation, calcified nodule formation did not affected. Conclusion: Taken together, these results suggest that irradiation at the dose of 10-20 Gy would not affect apoptosis induction of osteoblasts. Cell cycle and calcified nodule formation were influenced by the level of differentiation of osteblasts.

  • PDF

Quantitative analysis of the TMJ movement with a new mandibular movement tracking and simulation system

  • Kim, Dae-Seung;Hwang, Soon-Jung;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Heo, Kyung-Hoe;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.203-208
    • /
    • 2008
  • Purpose : The purpose of this study was to develop a system for the measurement and simulation of the TMJ movement and to analyze the mandibular movement quantitatively. Materials and Methods : We devised patient-specific splints and a registration body for the TMJ movement tracking. The mandibular movements of the 12 subjects with facial deformity and 3 controls were obtained by using an optical tracking system and the patient-specific splints. The mandibular part was manually segmented from the CT volume data of a patient. Three-dimensional surface models of the maxilla and the mandible were constructed using the segmented data. The continuous movement of the mandible with respect to the maxilla could be simulated by applying the recorded positions sequentially. Trajectories of the selected reference points were calculated during simulation and analyzed. Results : The selected points were the most superior point of bilateral condyle, lower incisor point, and pogonion. There were significant differences (P<0.05) between control group and pre-surgical group in the maximum displacement of left superior condyle, lower incisor, and pogonion in vertical direction. Differences in the maximum lengths of the right and the left condyle were 0.59${\pm}$0.30 mm in pre-surgical group and 2.69${\pm}$2.63 mm in control group, which showed a significant difference (P<0.005). The maximum of differences between lengths of the right and the left calculated during one cycle also showed a significant difference between two groups (P<0.05). Conclusion : Significant differences in mandibular movements between the groups implies that facial deformity have an effect on the movement asymmetry of the mandible. (Korean J Oral Maxillofac Radiol 2008; 38 : 203-8)

  • PDF

Effect of retinoic acid on the radiosensitivity of normal human oral keratinocyte (Retinoic acid가 사람 정상 구강각화세포의 방사선감수성에 미치는 영향에 관한 연구)

  • Lee Jean;Heo Min-Suk;Lee Sam-Sun;Oh Sung-Ook;Lee Sul-Mi;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • Purpose : To evaluate the effect of all-trans-retinoic acid (ATRA) on the radiosensitivity of normal human oral keratinocyte (NHOK). Materials and methods: Relative cell survival fraction including SF2 (survival fraction at 2 Gy) was calculated on the basis of colony formation assay. Data were fitted to the linear-quadratic model to establish the survival curve and calculate α and β values. Using flow cytometry at 1, 2, 3, 4, and 5 days after exposure to 2 and 10 Gy irradiation, cell cycle arrest and apoptosis were analysed. To understand the molecular mechanism of the radiosensitization of ATRA on NHOK, proteins related with apoptosis and cell cycle arrest were investigated by Western blot analysis. Results: Treatment with ATRA resulted in a significant decrease of SF2 value for NHOK from 0.63 to 0.27, and increased α and β value, indicating that ATRA increased radiosensitivity of NHOK. ATRA increased LDH significantly, but increasing irradiation dose decreased LDH, suggesting that the radiosensitizing effect of ATRA is not directly related with increasing cell necrosis by ATRA. ATRA did not induce appotosis but increased G2 arrest after 10 Gy irradiation, implying that the increased radiosensitivity of NHOK may be due to a decrease in mitosis casued by increasing G2 arrest. ATRA inhibited the reduction of p53 at 3 days after l0Gy irradiation and increased p21 at 1 day after 10 Gy irradiation. Further study is required to determine the precise relationship between this effect and the radiosensitizing effect of A TRA. Conclusion: These results suggested that ATRA increase radiosensitivity by inhibiting mitosis caused by increasing G2 arrest.

  • PDF

Three-dimensional assessment of condylar surface changes and remodeling after orthognathic surgery

  • Lee, Jung-Hye;Lee, Woo-Jin;Shin, Jae-Myung;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.25-31
    • /
    • 2016
  • Purpose: This study was performed to evaluate condylar surface changes and remodeling after orthognathic surgery using three-dimensional computed tomography (3D CT) imaging, including comparisons between the right and left sides and between the sexes. Materials and Methods: Forty patients (20 males and 20 females) who underwent multi-detector CT examinations before and after surgery were selected. Three-dimensional images comprising thousands of points on the condylar surface were obtained before and after surgery. For the quantitative assessment of condylar surface changes, point-to-point (preoperative-to-postoperative) distances were calculated using 3D processing software. These point-to-point distances were converted to a color map. In order to evaluate the types of condylar remodeling, the condylar head was divided into six areas (anteromedial, anteromiddle, anterolateral, posteromedial, posteromiddle, and posterolateral areas) and each area was classified into three types of condylar remodeling (bone formation, no change, and bone resorption) based on the color map. Additionally, comparative analyses were performed between the right and left sides and according to sex. Results: The mean of the average point-to-point distances on condylar surface was $0.11{\pm}0.03mm$. Bone resorption occurred more frequently than other types of condylar remodeling, especially in the lateral areas. However, bone formation in the anteromedial area was particularly prominent. No significant difference was found between the right and left condyles, but condylar surface changes in males were significantly larger than in females. Conclusion: This study revealed that condylar remodeling exhibited a tendency towards bone resorption, especially in the lateral areas. Condylar surface changes occurred, but were small.

X-ray radiation at low doses stimulates differentiation and mineralization of mouse calvarial osteoblasts

  • Park, Soon-Sun;Kim, Kyoung-A;Lee, Seung-Youp;Lim, Shin-Saeng;Jeon, Young-Mi;Lee, Jeong-Chae
    • BMB Reports
    • /
    • v.45 no.10
    • /
    • pp.571-576
    • /
    • 2012
  • Radiotherapy is considered to cause detrimental effects on bone tissue eventually increasing bone loss and fracture risk. However, there is a great controversy on the real effects of irradiation itself on osteoblasts, and the mechanisms by which irradiation affects osteoblast differentiation and mineralization are not completely understood. We explored how X-ray radiation influences differentiation and bone-specific gene expression in mouse calvarial osteoblasts. Irradiation at 2 Gy not only increased differentiation and mineralization of the cells, but also upregulated the expression of alkaline phosphatase, type I collagen, osteopontin, and osteocalcin at early stages of differentiation. However, irradiation at higher doses (>2 Gy) did not stimulate osteoblast differentiation, rather it suppressed DNA synthesis by the cells without a toxic effect. Additional experiments suggested that transforming growth factor-beta 1 and runt-transcription factor 2 play important roles in irradiation- stimulated bone differentiation by acting as upstream regulators of bone-specific markers.

Study on the Effect of Low Density Power Laser Radiation in Treating Gingival Inflammation - Clinical, Microbiological, Histological Study - (저출력 레이저 조사가 치은염증에 미치는 영향에 관한 연구)

  • Lee, Chang Woo;Kim, Ki Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.12 no.1
    • /
    • pp.5-16
    • /
    • 1987
  • 레이저의 의학적 이용은 고출력 레이저의 외과적 이용과 더불어 많은 진전을 하게 되었다. 근래에는 인체에 손상을 주는 고출력 레이저 외에도 조직의 파괴없이 인체조직에 유용한 효과를 줄 수 있는 저출력 레이저에 대한 연구가 적극적으로 시도되고 있다. 본 연구는 치은염을 가진 13명의 대상에 대해 Split-mouth design으로 대조군 및 실험군을 설정하여 실험군의 치은에 저출력 레이저(Biotherapy dental Laser 3DL)를 격일로 4회 조사한 후 plaque index, pocket depth, sulcus bleeding index, supragingival과 subgingival plaque의 bacterial morphotype의 비율 및 광학현미경을 통한 조직학적 염증 침윤상을 측정 평가하여 다음과 같은 결과를 얻었다. 1) 레이저 조사후 SBI(p<0.01)는 감소하였으나 PI는 별다른 변화가 없었다. 2) 레이저 조사에 따라 spirochetes(p<0.01)를 포함하여 motiles(p<0.05, p<0.01)은 감소된 반면 nommotiles(p<0.05, p<0.01) 증가하였다. 3) 레이저 조사 치은에서는 염증세포 침윤이 Dental(p<0.05) 및 oral(p<0.01) 양측 모두 감소되었다.

  • PDF

Late reconstruction of oncological maxillary defect with microvascular free flap (상악결손부의 2차적 재건에 있어 유리 혈관화 피판의 적용)

  • Kwon, Tae-Geon;Kim, Chin-Soo
    • The Journal of the Korean dental association
    • /
    • v.49 no.9
    • /
    • pp.527-534
    • /
    • 2011
  • Microvascular reconstruction of maxillary composite defect after oncologic resection has improved both esthetic and functional aspect of quality of life of the cancer patients. However, a lot of patients had prior surgery with radiation and/or chemotherapy as a part of comprehensive cancer treatment. Sometimes it is nearly impossible to find out adequate recipient vessel for maxillary reconstruction with microvascular anastomosis. Therefore long pedicle of the flap is needed to use distant neck vessels located far from the reconstruction site such as ipsilateral transverse cervical artery or a branch of contralateral external carotid artery. For this reason, although we know the treatment of the choice is osteocutaneous flap, it is difficult to use this flap when we need long pedicle with complex three dimensional osseous defect. Vascular option for these vessel-depleted neck patients can be managed by a soft tissue reconstruction with long vascular pedicle and additional free non-vascularized flap that is rigidly fixed to remaining skeletal structures. For this reason, maxillofacial reconstruction by vascularized soft tissue flap with or without the secondary restoration of maxillary bone with non-vascularized iliac bone can be regarded as one of options for reconstruction of profound maxillofacial composite defect resulted from previous oncological resection with chemo-radiotherapy.

A comparison of density of Insight and Ektaspeed plus dental x-ray films using automatic and manual processing (자동 및 수동현상에 따른 Insight 필름과 Ektaspeed Plus 필름의 흑화도 비교)

  • Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.17-22
    • /
    • 2001
  • Purpose: To compare the film density of Insight dental X-ray film (Eastman Kodak Co., Rochester, NY, USA) with that of Ektaspeed Plus film (Eastman Kodak) under manual and automatic processing conditions. Materials and Methods : Insight and Ektaspeed Plus films were exposed at three different exposure conditions with an aluminum step wedge on the films under the three different exposure times. The exposed films were processed by both manual and automatic ways. The Base plus fog density and the optical density made by exposing step wedge were calculated using a digital densitometer (model 07-443, Victoreen Inc, Cleveland, Ohio, USA). The optical densities of the Insight and Ektaspeed film versus thickness of alumimun wedge at the same exposure time were plotted on the graphs. Statistical analyses were applied for comparing the optical densities of the two films. Results: The film density of both Insight films and Ektaspeed Plus films under automatic processing condition was significantly higher over the manual processing. The film density of Insight films was significantly higher than that of Ektaspeed Plus films on both automatic and manual processing conditions. Conclusion: The radiation exposure time can be reduced when using Insight over Ektaspeed Plus film. To take the full advantage of reducing exposure time, Insight film should be processed automatically.

  • PDF