• Title/Summary/Keyword: dental stone

Search Result 182, Processing Time 0.028 seconds

A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE (전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구)

  • Lee, Yong-Sik;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

AN EXPERIMENTAL STUDY ON THE FRACTURE STRENGTH OF CLASS II POSTERIOR RESTORATIONS (II급 와동에서 각종 구치용 수복물의 파절강도에 관한 실험적 연구)

  • Lee, Kye-Hyuck;Hur, Seung-Myun;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.357-367
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture strength of class II restored premolars with amalgam, posterior composite, amalgam - Ketac silver, resin - Ketac silver restorations at marginal ridge. Fifty extacted maxillary and mandibular premolar teeth that were caries free, fracture free, and restoration free were selected and randomly divided into five groups : Group 1 : 10 intact teeth, Group 2 : 10 teeth with class II cavities and restored with, amalgam, Group 3: 10 teeth with class II cavities and restored with posterior resin, Group 4 : 10 teeth with class II cavities and restored with amalgam - ketac silver, Group 5 : 10 teeth with class II cavities and restored with resin - Ketac silver. All teeth were mounted in base of dental stone within metal rings of 2cm diameter, exposing only the crown portion. Class II mesio - occlusal or disto - occlusal cavities were prepared into specimens of Group 2 through 5 by using a No. 710 fissure bur. The occlusal portion was prepared to a faciolingual width of 1.5mm and a pulpal depth of 1.5mm. The proximal protion was prepared to a faciolingual width of 4mm, a occlusogingival height of 4mm, and a gingival floor of 1.5mm. The teeth in Group 2 and 3 were resotored with silver amalgam apd posterior resin respectively. In Group 4 and 5, proximal portions were first filled with Ketac silver 1.5mm gingivally and remaining cavities were restored with amalgam and posterior resin respectively. All specimens were stored in 100 % relative humidity at $37^{\circ}C$ for 48 hours before testing. All teeth were subjected to a compressive load in a Universal Instron Testing Machine at marginal ridges. The loads required to fracture the restorations were recorded in killograms and the data obtained were subjected to statisticall analysis. The results were all follows : 1. The fracture strength of Group 1 which were unprepared were $100{\pm}10.1\;kg$ and the higher values than Group 2, 3, 4, 5 which were prepared and resotred. 2. In restored groups, Group 2 had the higher fracture strength($81.8{\pm}12.4\;kg$) than other groups and Group 4 had the lowest fracture strength($66.8{\pm}9.2kg$). 3. There were significant differences between fracture strength of between Group 1 and Group 3, 4, 5(P<0.05), but not significant difference between fracture strength of Group 2, 3, 4, 5(P>0.05).

  • PDF

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

THE EFFECT OF SCREW TIGHTENING SEQUENCE AND TIGHTENING METHOD ON THE DETORQUE VALUE IN IMPLANT-SUPPORTED SUPERSTRUCTURE (임플랜트 지지 상부구조물에서 나사조임순서와 조임방법이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo;Lee, Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.653-664
    • /
    • 2007
  • Statement of problem: The screw detorque value is a measure of the preload remaining in the screw just before detorquing. Purpose: This study evaluated the effect of different screw tightening sequences and tightening methods on detorque values for a well-fitting implant superstructure. Material and method: An implant superstructure that connected directly to four implants (Astra Tech) was fabricated on a fully edentulous mandibular acrylic resin model. Six well-fitting dental stone casts were made with a pickup impression of the superstructure from the acrylic resin model. To evaluate the effect of three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and two tightening methods (2-step and 1-step) on the stability of screw joint, the detorque values for a well-fitting implant superstructure were measured twice after screw tightening using 20 Ncm. Detorque values were analyzed using multi-way analysis of variance and two-way analysis of variance at a .05 level of significance. Results: 1. The mean detorque values for three screw tightening sequences were 12.3 Ncm, 12.6 Ncm, and 12.0 Ncm, respectively. 2. The mean detorque values for two screw tightening methods were 12.0 Ncm, and 12.2 Ncm, respectively. 3. The mean of mimimum detorque values for three screw tightening sequences and for two tightening methods were 10.6 Ncm, 11.1 Ncm, 10.5 Ncm, and 9.8 Ncm, respectively. 4. No statistically significant differences among the variables of screw tightening sequence and tightening method were found (p>.05) for detorque values and for mimimum detorque values. Conclusion: Within the limitations of this study, the screw tightening sequence and tightening method did not have a significant effect on the detorque values for a well-fitting implant superstructure.

Comparing the efficiency of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness (다양한 거칠기의 알루미늄 옥사이드(Al2O3) 연마석을 이용한 치주기구 날 세우기의 효율성 비교)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2014
  • Purpose: This study examined the efficiency and wear of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness. Materials and Methods: Thirty new No. 9-10 Gracey curets were used in this study. All curets had become dull after scaling and root planing. After similar blunting, the instruments were divided randomly into three groups (240, 600, 800 grit) containing 10 curets each. The stones were applied correctly to the lateral surface of each curet to maintain the $70-80^{\circ}$ angle. After resharpening, sharpness of the curets was examined by an optical microscope. After 20, 40, 60, and 80 strokes, the wear was measured at 1 mm and 2 mm from the tip of the cutting edge using a digital caliper. The data was analyzed statistically using analysis of variance (ANOVA) with repeated measures, 2-way ANOVA, and a Fisher's exact test. Results: The degree of sharpness increased significantly (P < 0.001) as the number of sharpening strokes grew for all stones. A comparison of the degree of sharpness on the same number of strokes showed that the 240 grit group significantly excelled the other groups on 5 and 10 strokes, respectively (P < 0.001). The mean wear showed no statistically significant difference among the groups (P > 0.05). Conclusion: The efficiency of Gracey curet resharpening was enhanced with more coarse stones, though we should consider the wear of the instrument during resharpening.

Photoelastic Stress Analysis of Fixed Partial Dentures (가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Cho, Won-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

A STUDY OF INTRAORAL ANATOMIC LANDMARKS OF KOREAN ADULT-UPPER JAW (성인 유치악자 상악골의 악궁과 치열궁의 형태에 관한 조사)

  • Oh, Yu-Ree;Lee, Sung-Bok;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.753-768
    • /
    • 1995
  • For accurate impression taking of dental patient and esthetic denture treatment of ednetulous patient, measuring between intraoral anatomic landmarks is useful.In this study the subjects selected at a random were two-jundred forty persons with a mean age 22.5(range 21-24) and were taken impression of by irreversible hydrocolloid impression material(Alginate). On the study model made by dental stone, each individual tray was made and final impresion was taken by border moilding. On final model measurings were performed with 3-dimensional measuring device and the values were analyzed by t-test The results is following : ABOUT THE MEASURED VALUES. 1. The width between maxillary right and left canine cusp tip was average 36.44mm(s.d. 2.48), man 36.67mm, woman 35.83mm(p<0.05). 2. The width between labial height of contour of maxillary right and left canine was average 40.08mm(s.d. 2.42), man 40.29mm, woman 39.52mm(p<0.05). 3. The width between mesio-lingual cusps of maxillary first molar was average 43.14mm(s.d. 3.33), man 43.56mm, woman 42.05mm(p<0.05). 4. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary first molar was average 64.89mm(s.d. 3.88), man 65.58mm, woman 62.92mm(p<0.05). 5. The width between buccal alveolar ridge on axis of mesiolingual cusp of right and left maxillary second molar was average 68.58mm(s.d. 3.91), man 69.29mm, woman 66.30mm (p<0.05). 6. The width between right and left hamular notch was average 49.80mm(s.d. 3.96), man 50.70mm, woman 48.20mm(p<0.05). 7. The length from labial heigth of contour of maxillary central incisor to center of incisive papilla was average 9.52mm(s.d. 1.18), man 9.46mm, woman 9.63mm(p>0.05). 8. The length from labial heigth of contour of maxillary central incisor to palatine fovea was average 53.27mm(s.d. 2.93), man 53.93mm, woman 52.08mm(p<0.05). 9. The center of incisive papilla ws located posterior to intercanine line at 0.40mm(s.d. 1.16), man 0.51mm, woman 0.11mm(p<0.05). 10. The height from incisal edge of maxillary central incisor to the labial vestibule was average 21.84mm(s.d. 1.38), man 22.01mm, woman 21.00mm(p<0.05). 11. The height from mesiolingual cusp of maxillary first molar to buccalvestible was average 17.45mm(s.d. 1.42), man 17.56mm, woman 17.08mm(p>0.05). 12. The height from hamular notch to standard occlusal plane was average 6.84mm(s.d. 1.06), man 6.91mm, woman 6.70mm(p>0.05). 13. The height from the deepest point of palatal vault to standard occlsalplane was average 19.95 mm(s.d. 2.03), man 20.19mm, woman 19.12mm(p<0.05). ABOUT THE ARCH FORM 1. The arch form was able to classify into four typr by the rate of the measured values. Each arch form distribution was that the 1 group had 32.46% the 2 group 2.19%, the 3 group 52.83%, the 4 group 12.72%. The sexual composition was that in 1 group man had 73.5%, woman 26.5%, in 2 group man had 40.0%, woman 60.0%, in 3 group man had 83.3%, woman 16.7%, and in 4 group man had 55.17%, woman 44.83%. 2. When canine cusp tip was marked as point O, the intersection point between labial height of contour of maxillary central incisor and intermaxillary suture as point A, height of contour of maxillary second molar buccal alveolar ridge as B point, ${\angle}$AOB was measured $133.8^{\circ}$for the 1 group, $133.0^{\circ}$for the 2 group, $132.3^{\circ}$for the 3 group, $128.9^{\circ}$for the 4 group.

  • PDF

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

The effect of screw tightening techniques on the detorque value in internal connection implant superstructure (내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.243-250
    • /
    • 2010
  • Purpose: This study evaluated the effect of different screw tightening sequences and methods on detorque values in a well-fitting implant superstructure. Materials and methods: A fully edentulous mandibular master model and a metal framework directly connected to four parallel implants (Astra Tech) with a passive fit to each other were fabricated. Six stone casts were made with a splinted impression technique to represent a 'well-fitting' situation with the metal framework. Detorque values were measured twice after screw tightening using 20 Ncm. Detorque values and minimum detorque values for three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and for two tightening methods (two-step and one-step) were analyzed using multi-way analysis of variance and two-way analysis of variance, respectively, at a .05 level of significance. Results: The mean detorque values for screw tightening sequences ranged from 12.8 Ncm (2-4-3-1) to 13.1 Ncm (2-3-1-4), and for screw tightening methods were 13.1 Ncm (two-step) and 11.8 Ncm (one-step). The mean of mimimum detorque values for screw tightening sequences were 11.1 Ncm (1-2-3-4) and 11.2 Ncm (2-4-3-1 and 2-3-1-4), and for screw tightening methods were 11.2 Ncm (two-step) and 9.9 Ncm (one-step). No statistically significant differences among three screw tightening sequences were found for detorque values and for mimimum detorque values. But, statistically significant differences between two screw tightening methods were found for two values. Two-step screw tightening method showed higher detorque value (P = .0003) and higher minimum detorque value (P = .0035) than one-step method. Conclusion: Within the limitations of this study, the screw tightening sequence was not a critical factor for the detorque values in a well-fitting implant superstructure by the splinted impression technique. But, two-step screw tightening method showed greater detorque values than one-step method.