• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.031초

HALOGEN LIGHT CURING UNIT 과 LIGHT EMITTING DIODES CURING UNIT 을 이용하여 중합되어진 복합레진의 마모 특성 비교 (Wear Of Resin Composites Polymerized By Conventional Halogen Light Curing And Light Emitting Diodes Curing Units)

  • 이권용;김환;박성호;정일영;전승범
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1057-1060
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion with sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed the least wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as a curing unit for composite resin restorations.

  • PDF

복합레진의 미세누출에 관한 연구 (AN IN VITRO STUDY OF MICROLEAKAGE OF COMPOSITE RESINS)

  • 이선영;양연미;백병주;전철완;김재곤
    • 대한소아치과학회지
    • /
    • 제30권4호
    • /
    • pp.593-599
    • /
    • 2003
  • 치과의 수복재로 널리 쓰이는 복합레진의 미세누출에 대한 할로겐광과 플라즈마광의 영향을 비교하고, 유동성 복합레진과 할로겐광으로도 중합시간이 20초로 단축된 복합레진 $Filtek^{TM}$ Z250이 미세누출면에서 기존에 널리 쓰이던 복합레진인 Z100을 대체할 수 있을지를 평가하며, 미세누출에 미치는 adhesive resin의 영향을 알아보고자 본 실험을 수행하였다. 발거된 치아에 5급 와동을 형성하고 레진의 충전은 각 군에 따라 시행하였다. 유동성복합레진 $Filtek^{TM}Flow$와 Z100, $Filtek^{TM}Z250$을 이용하였고, 할로겐광과 플라즈마광을 이용하여 중합하였다 충전이 완료된 시편은 보관, 연마, 열순환을 시행하고, 1% methylene blue를 침투시킨 후 협설로 절단하여 미세누출 정도를 관찰하여 다음과 같은 결론을 얻었다. 1. $Filtek^{TM}Flow$$Filtek^{TM}Z250$ 모두 광원에 따른 미세누출의 차이는 없었다(p>0.05). 2. 유동성 복합레진인 $Filtek^{TM}Flow$는 복합레진 $Filtek^{TM}Z250$과 Z100에 비해 통계적으로 유의성있는 큰 미세누출을 보여(p<0.05) 유동성 복합레진만으로 수복한다면 미세누출의 위험이 커질 것이다. 3. Adhesive resin을 도포한 것이 할로겐광을 이용한 경우와 플라즈마광을 이용한 경우 모두에서 통계적으로 유의하게 미세누출을 감소시켰다.(p<0.05)

  • PDF

Comparison of Surface Microhardness of the Flowable Bulk-Fill Resin and the Packable Bulk-Fill Resin according to Light Curing Time and Distance

  • Hyung-Min Kim;Moon-Jin Jeong;Hee-Jung Lim;Do-Seon Lim
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.123-131
    • /
    • 2023
  • Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking. Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

Comparison of Shear Bond Strength in Novel Calcium Silicate-Based Materials to Composite Resin

  • Wonkyu Shin;Hyuntae Kim;Ji-Soo Song;Teo Jeon Shin;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Hong-Keun Hyun
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.443-451
    • /
    • 2023
  • The purpose of this study was to evaluate whether the newly introduced calcium silicate-based materials with fast-setting properties could be appropriately used as basement materials in indirect pulp treatment (IPT). This was performed by quantifying the durability of adhesion between the material and composite resin, measured by the shear bond strength (SBS). Five calcium silicate-based materials, TheraCal LC® (TLC), TheraCal PT® (TPT), TheraBase® (TB), Well-RootTM PT (WPT), and Endocem® MTA (EMTA), as well as two glass ionomer-based materials, Fuji II and Fuji II LC, were included. Specimens containing these materials were manufactured and bonded to composite resin with a universal adhesive applied in self-etch mode. The SBS values and failure modes were recorded, and the mean SBSs of the materials were compared. Both TPT and TB exhibited SBS values that were similar to TLC, while both WPT and EMTA appeared to have statistically lower SBS values. Mixed failure was commonly observed in TLC and TPT, while all WPT and EMTA samples showed cohesive failure. In comparison with TLC and TPT, more samples with cohesive failure were observed in TB, implying that this material forms a stronger bond with composite resin. Together with the ability of TB to chemically bind to dentin due to its 10-methacryloyloxydecyl dihydrogen phosphate component, TB seems to be a promising material for IPT within the limitations of this in vitro study.

치과용 콤포짓트 레진의 수분 흡수에 따른 압축강도와 굴곡강도의 변화에 관한 연구 (A STUDY ON CHANGE OF COMPRESSIVE STRENGTH AND FLEXURAL STRENGTH OF DENTAL COMPOSITE RESIN AFTER WATER STORAGE)

  • 정내정;김정욱;이상훈
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.146-153
    • /
    • 2001
  • 콤포짓트 레진의 다양한 성분은 기계적 성질에 많은 영향을 미치고, 수복물 주위의 환경 또한 재료의 성질에 많은 영향을 줄 수 있다. 구강 내에서 수복된 콤포짓트 레진은 항상 수분에 노출되어 있고, 콤포짓트 레진의 매트릭스는 수분을 흡수할 수 있으므로, 그 결과 콤포짓트 레진은 팽창하게 된다. 또한 콤포짓트 레진의 수분 흡수가 표면강도와 마모저항의 저하와 관계된 다고 알려져 있는바 저자는 치과용 콤포짓트 레진의 수분 흡수에 따른 압축강도와 굴곡강도의 변화에 관하여 알아보고자 하였다. 재료는 1군을 Z-100(3M, U.S.A.), 2군을 Spectrum(Dentsply, U.S.A.), 3군을 Clearfil AP-X(Kuraray, Japan), 4군을 Pyramid(Bisco, U.S.A), 5군을 Heliomolar(Vivadent, Germany)로 나누어 7일, 30일, 60일, 120일간 증류수에 넣어 $37^{\circ}C$에서 보관한 후 Instron 6022(Instron, U.K.)를 이용하여 압축강도와 굴곡강도를 측정하여 다음과 같은 결과를 얻었다. 1. 7일, 30일, 60일, 120일로 기간이 증가함에 따라 모든 군에서 압축강도가 감소하였다(p<0.05). 2. 7일, 30일, 60일, 120일로 기간이 증가함에 따라 모든 군에서 굴곡강도가 감소하였다(p<0.05). 3. Hybrid type인 1, 2, 3군에 비해 matrix 비율이 높은 microfine type인 5군이 강도가 낮았다.

  • PDF

Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향 (THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT)

  • 하점임;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

고체 amine 광개시제에 따른 치과용 복합수지의 중합효율 (Photopolymerization efficiency of dental resin composites with solid amine photoinitiators)

  • 선금주
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.43-52
    • /
    • 2006
  • Three t-amines, 4-(dimethylamino)benzoic acid (ABA), 4-(dimethylamino)benzaldehyde (MBA), 4-(dimethylamino)benzophenone (MBP), were investigated as new visible light photoinitiators for a dental resin composite of UDMA in order to improve photopolymerization effect. Three t-amines mixed with three photosensiizers, CQ, PD and DA, respectively. And the photopolymerization effect of photoinitiators were compared with that of 4-(dimethylamino)ethyl methacrylate (AEM), the most widely used photoinitiator. The photopolymerization efficiency of UDMA containing the photoinitiator increased with irradiation time. The increase was in the order: MBP

  • PDF

항우식성 복합레진의 가능성 (DEVELOPMENT OF ANTICARIOGENIC COMPOSITE RESIN)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.65-68
    • /
    • 2010
  • 복합레진의 개발 및 환자의 심미적 욕구로 인해 기존의 아말감을 복합레진 수복이 빠른 속도로 대체하고 있다. 하지만 복합레진의 경우 술식의 어려움, 중합수축으로 인한 응력의 발생, 재료의 파절, 이차우식등의 문제를 가지고 있으며 아직까지 복합레진 수복을 위해서는 치과용 접착제의 사용이 필수적이다. 이에 본 글에서는 현재 복합레진이 가지고 있는 문제점을 극복하기 위해 복합레진 수복의 가장 많은 실패 원인으로 알려진 이차우식을 억제할 수 있는 재광화 물질을 방출할 수 있는 복합레진의 개발이 어디까지 이루어지고 있는지 살펴보고 앞으로의 임상적용 가능성에 대해 생각해보고자 한다.

저점도 Bis-GMA 유도체로부터 제조된 고분자계 치과 수복용 복합재의 특성 (Characteristics of Polymeric Dental Restorative Composites Fabricated from Bis-GMA Derivatives Having Low Viscosity)

  • 전미영;송정오;김창근
    • 폴리머
    • /
    • 제31권6호
    • /
    • pp.491-496
    • /
    • 2007
  • 고분자계 치아 수복용 복합재에서 2,2-bis[4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane(Bis-GMA) 70 wt%와 희석제인 triethylene glycol dimethacrylate(TEGDMA)가 30 wt% 포함된 혼합물이 레진 기질로 사용되고 있다. Bis-GMA의 높은 점도로 인해 첨가되는 TEGDMA는 수복재의 높은 경화 수축과 물성 저하의 원인이 된다. 본 연구에서는 TEGDMA 첨가량을 감소시켜 우수한 특성을 나타내는 수복재를 제조하기 위해 저점도 Bis-GMA 유도체들을 이용하여 새로운 치과용 수복재를 제조하였다. 히드록실기를 포함하지 않는 Bis-GMA 유도체들의 경화 특성은 Bis-GMA와 비슷하였지만 이들의 흡습성과 점도는 Bis-GMA에 비해 크게 낮았다. Bis-GMA 유도체를 포함한 수복재를 제조하여 경화 수축률, 흡습성, 기계적 물성을 실험한 결과 기존 상업적으로 사용되는 수복재보다 낮은 흡습성과 탁월한 물성을 나타내었고, 경화 수축률도 약 25% 감소하였다.

임상가를 위한 특집 2 - 심미수복용 레진 (Tooth-colored Restorative Resin Composites)

  • 권태엽
    • 대한치과의사협회지
    • /
    • 제51권1호
    • /
    • pp.12-17
    • /
    • 2013
  • Curing methods for denial resin-based materials are limited because of the need to polymerize quickly in the oral cavity at an ambient temperature. At present, most dental restorative composites use a camphorquinone-amine complex initiation, visible light-cure, one-component systems. Clinically, it is important to try to optimize the degree of conversion of res in composites using proper manipulation and adequate light-curing techniques to ensure the best outcome.