• Title/Summary/Keyword: dental resin

Search Result 1,266, Processing Time 0.024 seconds

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

The Effect of Human Appendage Muscle Strength on Increase in Vertical Dimension from Intercuspal Position of Mandible (교두감합위로부터 출발한 수직교합고경의 단계적 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Hong, Dong-Hee;Lee, Sung-Bok;Choi, Dae-Kyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.3
    • /
    • pp.169-183
    • /
    • 2003
  • According to our recent investigation that the increase in the occlusal vertical dimension made the appendage muscle strength got higher, the occlusal appliances were made by increasing the occlusal vertical dimension "from the centric relation" position of the mandible. In this experiment, the authors tried to study the change in the appendage muscle strength due to increase in occlusal vertical dimension from intercuspal position(ICP) of mandible with the same subjects and manner as the former experiment. For this study, ten male athletes in a mean age of 23 year who were joined the former study were selected. All the subjects had a complete or almost complete set of natural teeth and reported no subjective symptoms of temporomandibular disorders. Upper and lower casts were mounted on the semi-adjustable articulator at the intercuspal position and a point was marked on the attached gingival area between the right canine and the right 1st. premolar in each upper and lower cast. From the points, the occlusal vertical dimension was increased by 2mm, 3.5mm and 5mm, and then each 10 maxillary type occlusal splint at each 3-increased position were fabricated with heat curing clear acrylic resin. Including the intercuspal position, the 3 kinds of occlusal splints were placed on the subjects individually, and then isokinetic muscle strength on 7 parts of the human appendage which are shoulder, knee, ankle, wrist, forearm, elbow and hip was measured with the CYBEX 6000 SYSTEM (Lumex, NewYork, USA). The results were as follows: The highest mean value in muscular strength was shown at the position of 2mm-increased vertical dimension. The muscle strength during internal/external rotation of shoulder and knee, plantarflexion of ankle, flexion of elbow, and flexion and extension of hip at the increased occlusal vertical dimension position were significantly higher than them at the intercuspal position (p<0.05). Only in view of the increase in the appendage muscle strength, regardless of the way of making the occlusal splints by elevating the occlusal vertical dimension from the centric relation position or intercuspal position, the occlusal splints had an effect on the increase of isokinetic muscle strength at the occlusal vertical dimension which increased within the proper range on the habitual arc of closure.

COMPARISON OF MARGINAL MICROLEAKAGE BETWEEN LOW AND HIGH FLOWABLE RESINS IN CLASS V CAVITY (5급 와동에서 저유동성과 고유동성 레진의 변연 미세누출 비교)

  • Bae, Sang-Bae;Cho, Young-Gon;Lee, Myeong-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.477-483
    • /
    • 2009
  • The purpose of this study was to compare the microleakage of low and high viscosity flowable resins in class V cavities applied with 1-step adhesives. Forty Class V cavities were prepared on the cervices of buccal and lingual surfaces of extracted molar teeth and divided into four groups (n=8). Cavities were restored with AQ Bond Plus /Metafil Flo $\alpha$, G-Bond/ UniFil LoFlo Plus (Low flow groups), AQ Bond Plus/Metafil Flo and G-Bond/UniFil Flow (High flow group), respectively. Specimens were immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed microleakages at the enamel and dentinal margins. In conclusion, the low viscosity flowable resins showed lower marginal microleakage than do the high vis cosity flowable resins in class V cavities.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

The evaluation of surface roughness and polishing time between polishing systems (연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가)

  • Kim, Ye-Mi;Shin, Su-Jung;Song, Min-Ju;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

Effects of Occlusal Condition and Clenching Force on the Mandibular Torque Rotational Movement (교합조건 및 이악물기 힘의 변화가 하악의 비틀림 회전운동에 미치는 영향)

  • Oh, Min-Jung;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.411-426
    • /
    • 2005
  • The purpose of this study was to investigate the effects of occlusal condition and clenching level on the mandibular torque rotational movement. For this study, healthy 14 men without any symptoms and signs of temporomandibular disorders were selected. Mandibular torque rotational movement was observed in each circumstance of combination of three occlusal conditions such as natural dentition, with wafer of 3.6 mm thickness, and wafer with resin stop of 14 mm thickness total during hard biting of bite stick at maximum voluntary contraction(MVC) and 50% of MVC level of surface EMG activity of masseter muscle. Electromyographic activity and mandibular torque rotational movement were observed using BioEMG and BioEGN in $BioPak^{(R)}$ system. Each biting movement in each circumstance was composed of clenching one time and hard biting of wooden stick two times. The observed items were opening distance, velocity and amount of torque rotational movement in mandibular movement, and the data were statistically processed with $SPSS^{(R)}$ windows (ver.10.0). The results of this study were as follows: 1. There were no differences in the mandibular movement distance between those value in both biting sides, and between those in both clenching forces, but the mandibular velocity showed a different results by clenching force. For the amount of torque rotational movement, there were no difference in the value of the frontal plane but some significant difference was in the value of the horizontal plane by biting side. 2. The mandibular movement distance and the mandibular velocity in both planes were higher by maximum voluntary contraction than those by half maximum voluntary contraction, and amount of torque rotational movement in the horizontal plane was also increased by maximum voluntary contraction. 3. The opening distance in both planes were decreased with the increase of vertical dimension of occlusion, namely, by the occlusal appliances, and this pattern was also showed in the mandibular velocity in case of hard biting by maximum voluntary contraction. However, the amount of torque rotational movement were not different by the increase of vertical dimension of occlusion. 4. The value of angle and distance of the torque rotational movement in the hard biting of wooden stick were generally higher than those in the clenching without wooden stick in both planes without regard to occlusal conditions and/or clenching forces.

Intrapulpal Temperature Change during Cavity Preparation on the Enamel and Dentin with an Er:YAG Laser (Er:YAG 레이저를 이용한 법랑질 및 상아질 와동 형성시의 치수내 온도변화)

  • Yang, Hee-Young;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The purpose of our study was to investigate whether the intrapulpal temperature during cavity preparation of enamel or dentin with Er:YAG laser still remained in range of safety for dental pulp protection when combined with appropriate water flow rate. The effect of different pulse repetition rates at the same pulse energy during ablation was evaluated as well. Caries-free, restoration-free extracted human molar teeth were prepared for the specimen and divided two experimental groups of enamel and dentin. Each group comprised 5 specimens and each of tooth specimens were embedded into a resin block each and measuring probe was placed on the irradiated pulpal walls. For experiments of dentin ablation, enamel layers were prepared to produce dentin specimen with a same dentin thickness of 2 mm. A pulse energy of Er:YAG laser was set to 300 mJ and three different pulse repetition rates of 20 Hz, 15 Hz and 10 Hz were employed. Laser beam was delivered with 3 seconds and less per application over enamel and dentin surfaces constant sized by $3\;mm{\times}2\;mm$ and water spray added during irradiation was a rate of 1.6 ml/min. Temperature change induced by Er:YAG laser irradiation was monitored and recorded While enamel was ablated, there was no significant difference of temperature related to pulse repetition rates(p=0.358) and temperature change at any pulse repetition rate was negligible. Significant statistical difference in temperature changes during cavity preparation in dentin existed among three different pulse groups(p=0.001). While temperature rise was noticeable when the dentinal wall was perforated, actual change of temperature due to Er:YAG laser irradiation was not enough to compromise safety of dental pulp when irradiation was conjugated with appropriate water spray. Conclusively, it can be said that cavity preparation on enamel or dentin with an Er:YAG laser is performed safely without pulp damage if appropriate volume of water is sprayed properly over the irradiated site.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

COMPARATIVE STUDY ON FLUORIDE RELEASE AND RE-UPTAKE CAPACITY OF SEVERAL FLUORIDE-RELEASING RESTORATIVE MATERIALS (수종의 수복재의 불소 적용법에 따른 불소 유리에 관한 비교 연구)

  • Lee, Yeon-Ho;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.25-34
    • /
    • 2006
  • Fluoride released from dental restorative materials effectively declines the incidence and activity of dental caries and inhibits tooth demineralization. This study investigated the fluoride release and uptake characteristics of one composite resin $(Z-250^{TM})$ three glass ionomer-based restorative material ($Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$, Fuji IX GP $Fast^{(R)}$) Forty discs(6mm diameter and 1mm height) were prepared for each material. Each disc was immersed in 5ml of distilled water within polyethylene vial and stored at $37^{\circ}C$. The distilled water was changed every 24 hours and the release of fluoride was measured for 31 days. At the end of this period, each specimen was subjected to one of four treatments : (A) no fluoride treatment (control), (B) application of a fluoride dentifrice (500ppm) for three minutes three times; (C) application of the 1.23% acidulated phosphate fluoride(APF) foam for one minute once, (D) the same regimen as (B), plus application of the APF foam for one minute once. Then, all samples were reassessed for an additional 7 days. For all samples, the greatest fluoride release was observed after the first day of the study but diminished with time. On the 7th day of the study, fluoride release level was stabilized. Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ released higher amount of fluoride than other materials ; however, no statistically significant difference was found from Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$. The amount of fluoride of $Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ was increased after fluoride treatment, and diminished with time.

  • PDF