• Title/Summary/Keyword: dental research

Search Result 4,618, Processing Time 0.037 seconds

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

The Present State and Curriculum Implementation Overview of the Nursing-Specialized Vocational High Schools (특성화고등학교 간호과 운영 현황 및 교육과정 운영실태 분석)

  • Yoon, In-Kyung;Jang, Myung-Hee;Lee, Hyun-Young
    • Journal of vocational education research
    • /
    • v.35 no.4
    • /
    • pp.19-46
    • /
    • 2016
  • The purpose of this study is to analyze the curriculum implementation of the Nursing-Specialized Vocational High School by researching on operation, organization and environment of the program of Nursing. This study aims to improve the curriculum of the Nursing-Specialized Vocational High School. This study has analyzed previous existing studies, Link of School info, Educational Statistics and data indicating establishment, operation and curriculum of the department of Nursing which have been collected from web sites of institutions and associations relevant to Nurse Education. The major results of this study are as follows: 1) As of the first semester of the year 2016, out of a total of thirty eight Specialized Vocational High Schools and Meister High Schools in the country, 6.4% of the schools have nursing educational programs. These schools have established the programs under various names, such as Health Nursing, Dental Health Nursing, Nursing, Nursing and Medical Tourism, Accounting in Nursing and Nursing Management, etc. Since 2012, enrollment rates have increased while post-graduation employment rates have decreased, with the average employment rate of Specialized Vocational High School graduates having reached up to 46% by 2015. 2) The Nursing-Specialized Vocational High School aims to create skilled Nurses Assistant such as Nurse Aide and Care giver. The program is successful in providing necessary courses to acquire required certification and proficient field experience but requires revisional changes in order to create a long-term program of sufficient qualification. The official requirement of 780 hours of field practice was completed during the three educational breaks from the first year of high school to the second year, while the curriculum was conducted separately in the field hospitals. 3) An average of two laboratory classrooms were available based on the facility requirement standard of Cities and Provinces Educational Policies. In order to secure proficient instructors of Nursing education, establishment of specific indicated subjects, regional placement, in-service education, research and supervision are essential for establishing excellence and continual improvement.

Comparative Clinical Study between Oriental Medicine and Oriental-western Medicine Treatment on Facial Nerve Paralysis (구안와사(口眼喎斜)에 대한 한의(韓醫) 및 한(韓)·서의(西醫) 협진(協診) 치료(治療)의 임상(臨床) 관찰(觀察))

  • Kang, Mi-Jung;Kim, Kee-Hyun;Hwang, Hyeon-Seo
    • Journal of Acupuncture Research
    • /
    • v.17 no.1
    • /
    • pp.55-66
    • /
    • 2000
  • The following results have been obtaind after examing 72patients with facial paralysis who were hospitalzed and treated through the time period of December 1st, 1996 to November 30th, 1999 at the Department of Acupuncture and Moxibustion of Seoul Oriental Medicine, Kyungwon University. During the examination, those 72 patients were divided into two groups, and One group was treated by oriental-western treatment, the other group was treated by oriental treatment. Oriental treatments were acupuncture and moxibustion, herb medicine, physical treatment and hygienic treatment. The one of main western treatments is steroid therapy. The results were obtained as follows : 1. In regard to signs at the first medical examination, lacrimation was showed highest number and facial paralysis, dysgeusia, hyperacusis were showed in numerical order. 2. In regard to prescription of oriental herb medicine, Kamissangbotang(加味雙補湯) was prescribed in greatest numbers and Boyangwhanotang(補陽還五湯), Kamiboiktang(加味補益湯), Ligigepungtang(理氣祛風湯) were prescribed in numerical order. 3. In regard to treatment number, 10~19 times for treatment was showed highest number and 1~9 times, 20~29 times, 40~49 times were showed in numerical order . 4. In regard to mean treatment times about injury region and main sign, the effect of oriental-western treatment was showed as follows: lacrimal gland disorder, hyperacusis, dysgeusia, facial paralysis were treated for 15.1, 27, 13.2 and 21.4 times, repectively. The effect of oriental treatment was showed as follows: lacrimal gland disorder, hyperacusis, dysgeusia, facial paralysis were treated for 34.8, 22.1, 33.8 and 16.3 times, respectively. 5. In regard ta the effect of treatment about injury region and main sign, oriental-western treatment was showed as follows: cases of lacrimal gland disorder were showed 1 of excellent case, 1 of fair case, 5 of good cases. In hyperacusis patients, there was showed 1 of fair case. In dysgeusia patients, there was showed 1 of excellent case, 3 of fair cases, 1 of good case. In facial paralysis, there were showed 5 of fair cases. Oriental treatment was showed as follows: In lacrimal gland disorder, the excellent were 4 cases, the fair were 10 cases, the good were 3 cases and the poor were 4 cases, In hyperacusis, the fair were 5 cases, the poor 2 cases. In dysgeusia, the excellent were 4 cases, the fair were 1 case, the good were 1 case and the poor was 1 case, In facial paralysis, the excellent were 9 cases, the fair were 4 cases, the good 3 cases and the poor were 3 cases. 6. The effect of total treatment was as follows: 30 cases were showed fair effect, 19 cases were showed excellent effect, 13 cases were showed good effect and 10 cases were showed poor effect. 7. In regard to attack factor, overlabour was showed highest number and wind-cold, mental stress, trauma, ear disease, common cold, dental diseae, reason unknwon were showed in numerical order. 8. In regard to premonitory symptoms, non significant symptoms were in 38 cases, the pain of peri-stylomastoid region were in 38 cases and headache, dysaesthesia of periorbit, dysgeusia, stomatitis, eyelid tic were showed in numerical order. 9. In regard to sex, male were 33 cases and female were 39 cases. The distribution of age was disclosed that thirty, forty, fifty, seventy, sixty, twenty and below twenty years were revealed in turn. Sex and paralytic side were showed as follows: male-left were 15 cases, male-right were 18 cases, female-left were 19 cases and female-right were 19 cases. In regard to attack frequence in month, March was showed highest number and January, April, May, August, October, etc were showed in numerical order. In regard to attack frequence in season, spring was showed highest number and winter, summer, fall were showed in numerical order, but attack frequence between four seasons wasn't showed significant difference.

  • PDF

A study of sagittal condylar inclination and occlusal plane inclination of two semiadjustablearticulators with different reference plane (기준면이 다른 반조절성 교합기의 전방시상과로각과 교합평면경사각에 대한 연구)

  • Kim, Hyo-Jung;Lee, Sung-Bok;Choi, Dae-Gyun;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.420-430
    • /
    • 2008
  • Statement of problem & Purpose: Articulators are very important for education and overall clinical situation in the field of prosthodontics, however preexisting articulators are designed and built based on maxillofacial structures and mean values of mandibular movement of Western people. Purpose of this research is to find out a adequate basis for applicating these articulators, presently used for clinical education, for Korean. Material and methods: 59 Korean adults (41 males, 18 females), aged between 24 to 41, where selected for this study. Two pairs of both maxillary and mandibular models were made for each examinee. These models where attached to both KaVo PROTARevo 7 and Hanau Modular semiadjustable articulators by using facebow transfer, than sagittal condylar inclination, occlusal plane inclination and position of mandibular on the articulator where measured. Result and conclusion: 1. Mean sagittal condylar inclination for KaVo PROTAR semiadjustable articulator was $33.75^{\circ}$(standard deviation $12.46^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $40.72^{\circ}$(standard deviation $12.09^{\circ}$) for mean sagittal condylar inclination. 2. Mean occlusal plane inclination for KaVo PROTAR semiadjustable articulator was $-2.76{\circ}$(standard deviation $3.63^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $11.87^{\circ}$ (standard deviation $3.63^{\circ}$) for mean occlusal plane inclination. 3. On the average center of the mandibular dentition were in the range of 5 to 7 mm of the central position of the articulator. Both anterior and posterior dentition were positioned at the center of the articulator vernacularly for KaVo PROTAR semiadjustable articulators, meantime for Hanau Modular semiadjustable articulator, anterior dentition was positioned 5 mm downwards and 3mm upwards for posterior dentition from vertically central position of the articulator.

Craniofacial morphologic alteration induced by bone-targeted mutants of FGFR2 causing Apert and Crouzon syndrome (어퍼트 및 크루즌 증후군을 유발하는 골조직 특이성 FGFR2 돌연변이에 의한 두개안면 형태의 변화)

  • Lee, Kee-Joon;Nah, Hyun-Duck;Tjoa, Stephen T. J.;Park, Young-Chel;Baik, Hyoung-Seon;Yun, Tae-Min;Song, Jin-Wook
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.284-294
    • /
    • 2006
  • Objective: Activating mutations in the fibroblast growth factor receptor-2 (FGFR2) have been shown to cause syndromic craniosynostosis such as Apert and Crouzon syndromes. The purpose of this pilot study was to investigate the resultant phenotypes induced by the two distinctive bone-targeted gene constructs of FGFR2, Pro253Arg and Cys278Phe, corresponding to human Apert and Crouzon syndromes respectively. Methods: Wild type and a transgenic mouse model with normal FGFR2 were used as controls to examine the validity of the microinjection. Micro-CT and morphometric analysis on the skull revealed the following results. Results: Both Apert and Crouzon mutants of FGFR2 induced fusion of calvarial sutures and anteroposteriorly constricted facial dimension, with anterior crossbite present only in Apert mice. Apert mice differed from Crouzon mice and transgenic mice with normal FGFR2 in the anterior cranial base flexure and calvarial flexure angle which implies a possible difference in the pathogenesis of the two mutations. In contrast, the transgenic mice with normal FGFR2 displayed normal craniofacial phenotype. Conclusion: Apert and Crouzon mutations appear to lead to genotype-specific phenotypes, possibly causing the distinctive sites and sequence of synostosis in the calvaria and cranial base. The exact function of the altered FGFR2 at each suture needs further investigation.

A CLINICAL STUDY OF CONGENITAL MISSING TEETH (선천성 결손치에 관한 임상적 연구)

  • Jeong, Hae-Kyoung;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju;Jung, Jin-Woo;Kim, Ha-Na;Kim, Mi-Ah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.245-252
    • /
    • 2009
  • The congenital missing of teeth is common, which takes place since the proliferation and differentiation are not allowed in that tooth bud fail to start development. The purpose of this study is to research incidence rate, number, and missing part of congenital missing teeth, and to study whether a person who has missing teeth has other abnormality of teeth or not. For this study, 1,520 subjects(aged 2.9$\sim$17) who had visited pediatric dentist department of Chonbuk national university dental hospital within 2 years were examined with an panoramic radiograph; exempting third molar missing state. The obtained results are as follows. 1. 8.88% among total subjects show missing teeth; male 9.05%, female 8.64% 2. The most frequently missing permanent teeth were the mandibular second premolars(22.3%). The most frequently missing primary teeth are mandibular lateral incisors(50%). 3. 43.3% patients have one permanent missing tooth, 34.3% have two, and 10.4% have more than six, respectively. In primary teeth, 86.7% patients have one missing tooth, and 13.3% have two missing teeth. 4. 18 patients(13.3%) have missing teeth as well as hyperdontia, while some patients have microdont, ectopic eruption, and fusion teeth.

  • PDF

STUDY ON MAXILLOFACIAL GROWTH AND PHYSICAL DEVELOPMENT OF GROWING CHILDREN (성장기 아동의 악안면 성장과 신체발육에 관한 연구)

  • Hwang, Chung-Ju;Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.963-978
    • /
    • 1997
  • Orthodontic patients are individuals that grow and develop ;therefore selection of the proper time for orthodontic treatment Is considered to be one of the most difficult and yet difficult factor.Since the development of cephalometric X-ray, amount and pattern of craniofacial growth change with aging could be predicted and became useful in the process of orthodontic treatment. The relationship between the mean values of cephalometric measurements and body height and weight was studied among the groups(boys and girls) of Korean children from the ages of 3-years to 12-years. 126 boys and 90 girls with no abnormality in growth and development and no history of orthodontic treatment from the ages of 3 years to 12 years were chosen as subjects: Cephalometric X-ray were taken for 2 years and hard tissue analysis based on Burstone's COGS, which was divided into measurements of 6 parts (Cranial base, Maxillar and Mandible, Vertical measurements, Horizontal measurements, Basal bone relationship, Dental measurements). The relationship between craniofacial growth and body height & weight was studied. The following conclusions were obtained : 1. The maximum growth in the measurements of cranial base, N-Ar(FH), N-Ba(FH) corresponded with the age with the maximum increasein body height & weight in both boys and girls. 2. Genial angle gradually decreased with aging in both boys and girls. 3. N-ANS(L) showed greater amount of growth than ANS-Me(L), and this had greater influence on facial profile. 4. $N-A-Pog^{\circ}$ decreased with aging, and mandibular growth exceeded maxillary growth in amount and rate. 5. Length of Y-axis increased, but Y-axis to FH plane remained constant. This show that mandible grows at a constant angulation to cranial base. 6. As Permanent teeth erupt, interincisal angle deceased.

  • PDF

EFFECT OF A NEW RESIN MONOMER ON THE MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (새로운 레진 단량체가 복합레진수복물의 미세변연누출에 미치는 영향)

  • Bae, J.H.;Kim, Y.K.;Yoon, P.Y.;Lee, M.A.;Cho, B.H.
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.469-475
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of a new resin monomer on the microleakage of composite resin restorations. By adding new methoxylated Bis-GMA (Bis-M-GMA, 2,2-bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane) having low viscosity, the content of TEGDMA which has adverse effects on polymerization shrinkage might be decreased. As a result, microleakage might be improved. $2\;mm\;{\times}\;2\;mm\;{\times}\;2\;mm$ cavities with occlusal margins in enamel and gingival margins in dentin were prepared on buccal and lingual surfaces of 40 extracted human premolars. Prepared teeth were randomly divided into four groups and restored with Clearfil SE bond (Kuraray, Japan) and one of experimental composite resins; EX1, Experimental composite resin1 (Bis-M-GMA/TEGDMA = 95/5 wt%, 40 mm nanofillers); EX2, Experimental composite resin2 (Bis-M-GMA/TEGDMA = 95/5 wt%, 20 mm nanofillers); EX3, Experimental composite resin3 (Bis-GMA/TEGDMA = 70/30 wt%, 40 nm nanofillers); and Filtek Z250 (3M ESPE, USA) was filed as a control group. The restored teeth were thermocycled, and immersed in 2% methylene blue solution for 24 hours. The teeth were sectioned buccolingually with a low speed diamond saw and evaluated for microleakage under stereomicroscope. The data were statistically analyzed by Pearson Chi-Square test and Fisher Exact test (p = 0.05). The microleakage scores seen at the enamel margin were significantly lower than those of dentin margin (p = 0.007). There were no significant differences among the composite resins in the microleakage scores within each margin (p > 0.05). Bis-M-GMA, a new resin monomer having low viscosity, might in part replace high viscous Bis-CMA and might improve the quality of composite resin.

Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system (내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향)

  • Kim, Joo-Hyeun;Huh, Jung-Bo;Yun, Mi-Jung;Kang, Eun-Sook;Heo, Jae-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.206-214
    • /
    • 2014
  • This study is to evaluate how different bearing surface angles of abutment screw affect the mechanical stability of the joint in the conical seal design implant system. Materials and Methods: Internal connection type regular implants, two-piece cemented type abutments and tungsten carbide/carbon-coated titanium alloy abutment screws were selected. Titanium alloy screws with conical ($45^{\circ}$) and flat ($90^{\circ}$) head designs which fit on to abutment were fabricated. The abutments were tightened to implants with 30 Ncm by digital torque gauge. The loading was applied once to the central axis of abutment. The mean axial displacement was measured using micrometer before and after the tightening and loading (n = 5). The abutment was tightened to implants with 30 Ncm and T-shape stainless steel crown was cemented. Then the change in the amount of reverse-torque was measured after the repeated loading to the central axis, and the place 5 mm away from the central axis. Compressive bending and fatigue strength were measured at the place 5 mm away from the central axis (n = 5). Results: Both groups showed the largest axial displacement when abutment screw tightening and total displacement was greater in the flat head group compared to conical head group (P < 0.05). However, there were no significant differences in reverse torque value, compressive bending and fatigue strength (P > 0.05). Conclusion: Within the limitations of this study, the abutment screw head design had no effect on two groups regarding the joint stability, however the conical head design affected the settlement of abutment resulting in the reduced total displacement.