• Title/Summary/Keyword: dental radiology

Search Result 1,195, Processing Time 0.024 seconds

The effect of retinoic acid on radiosensitivity analyzed by linear-quadratic model and apoptosis in head and neck squamous carcinoma cell lines (두경부 편평세포암종세포주에서 retinoic acid가 linear-quadratic 모델을 적용한 방사선감수성과 apoptosis 유발에 미치는 영향)

  • Lee Eun-Sook;Kang Bum-Hyun;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.135-143
    • /
    • 2001
  • Purpose : To evaluate the effect of all-trans-retinoic acid on radiosensitivity and radiation-induced apoptosis in NHOK, HEp-2 and FaDu cell lines. Material and Methods: We measured the changes in survival fraction at 2 Gy (SF2), α and β after treatment of retinoic acid (1μM) prior to irradiation with doses of 2, 4, 6 and 10 Gy and correlated the radiosensitizing effect of retinoic acid with them. Also, apoptosis induction was assayed with the flow cytometry on days 1,2, 3, 4 and 5 after irradiation (2, 10 and 20 Gy) combined with retinoic acid. Results and Conclusion: SF2 values for NHOK, HEp-2 and FaDu cell lines were 0.54, 0.64 and 0.41, respectively and the cell line of FaDu was the most radiosensitive. For cell lines of NHOK and HEp-2, pretreatment of cells with retinoic acid resulted in a significant decrease of the SF2 values. The α/β ratios of x-ray survival curve were 8.714 (NHOK), 4.098 (HEp-2) and 11.79 (FaDu). The α/β ratio for NHOK decreased on pretreatment with retinoic acid, whereas those for HEp-2 and FaDu increased. Radiation induced apoptosis in all cell lines but, retinoic acid did not affect the apoptosis.

  • PDF

The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT (임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구)

  • Lee Sul-Mi;An Chang-Hyeon;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

Usefullness of panoramic radiograph for the improvement of periodic oral examination (구강검진의 효과 증진을 위한 파노라마방사선사진의 필요성에 관한 연구)

  • Shin, Min-Jung;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose : This study was designed to evaluate the efficacy and utility of panoramic radiograph for the improvement of the periodic oral examinations. Materials and Methods : Clinical examinations and panoramic examinations were done for the 242 subjects of oral examinations. The results of panoramic radiograph interpretation were compared with the clinical findings. Two questionnaires were created. One was carried out before the panoramic examination and the other done afterwards, to find out the subjects' cognition and satisfaction for the clinical and panoramic examinations. Results : 1. Panoramic findings showed a higher detection rate of 31.9% for periodontal diseases, and 23.1% for dental caries than clinical findings. 2. The additional abnormalities detected through panoramic examinations were impacted tooth in 81 subjects (33.6%), maxillary sinus abnormalities in 28 subjects (11.6%), condylar abnormalities in 5 subjects (2.1%), congenital and acquired dental anormalies in 59 subjects (24.5%), and other miscellaneous abnormalities in 34 subjects (14.1%). 3. 164 subjects (67.8%) were satisfied with the current periodic oral examination, and 75 subjects (31.1%) hoped for better accuracy. 4. In the first and second questionnaire, 154 subjects (67.0%) and 163 subjects (70.6%) responded respectively that panoramic examination was necessary, and 193 subjects (83.2%) responded that it actually helped. Conclusion : The panoramic examination was revealed to improve the effectiveness of the periodic oral examination and to increase the satisfaction of the subjects of examination.

Age-dependent Difference in the Computed Tomography Numbers of the Normal Parotid Gland of Koreans (나이에 따른 한국인 정상 이하선의 전산화단층촬영값의 차이)

  • Jeong Ho-Gul;Lee Eun-Sook;Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.451-458
    • /
    • 1999
  • Purpose : To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. Materials & Methods : 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views. the one showing the greatest parotid gland size was selected and its CT number was recorded. Also. CT numbers from both masseter muscle were recorded as its control. Results : There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age. there is a significant decrease in the CT number of parotid gland(p<0.05). There was no statistically significant difference in CT number between sexes except the 7th decade and beyond age group of parotid gland(p>0.05). Conclusion : As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having a salivary gland disease of the parotid gland. to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  • PDF

Apoptosis in the craniofacial tissues of irradiated growing rats

  • Heo Min-Suk;Choi Hang-Moon;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the apoptosis induction in tissues constituting the craniofacial region of growing rat by irradiation. Materials and Methods: The submandibular gland, brain, articular cartilage of condylar head, and calvarium were extracted from 20-day-old rats irradiated 10 Gy. Apoptosis of each tissue was examined by DNA fragmentation and estimated quantitatively using apoptotic index on TUNEL assay. Apoptotic index of each tissue was calculated by the equation for apoptotic cells/total cells × 1,000 on the images of confocal laser scanning microscopy. Apoptotic index was analyzed statistically according to the time lapse after irradiation on the tissues. Results : In the submandibular gland, apoptotic index was significantly increased from 6 hours after irradiation showing the highest value at 12 hours and decreased to the control level at 3 days after irradiation. In the brain, apoptotic index was abruptly reached to the maximum value at 6 hours after irradiation and decreased to the control level at 4 days after irradiation. Articular cartilage and calvarium showed no or little apoptotic signals. The results obtained by the apoptotic index accorded with that of DNA fragmentation. Conclusion : Radiation was closely related with the apoptosis of submandibular gland and brain but, not related with the apoptosis of the articular cartilage of condylar head and calvarium. The changes induced by radiation of the hard tissues would not be explained by apoptosis.

  • PDF

Interactive learning in oral and maxillofacial radiology

  • Ramesh, Aruna;Ganguly, Rumpa
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.211-216
    • /
    • 2016
  • Purpose: The use of electronic tools in teaching is growing rapidly in all fields, and there are many options to choose from. We present one such platform, Learning Catalytics$^{TM}$ (LC) (Pearson, New York, NY, USA), which we utilized in our oral and maxillofacial radiology course for second-year dental students. Materials and Methods: The aim of our study was to assess the correlation between students' performance on course exams and self-assessment LC quizzes. The performance of 354 predoctoral dental students from 2 consecutive classes on the course exams and LC quizzes was assessed to identify correlations using the Spearman rank correlation test. The first class was given in-class LC quizzes that were graded for accuracy. The second class was given out-of-class quizzes that were treated as online self-assessment exercises. The grading in the self-assessment exercises was for participation only and not accuracy. All quizzes were scheduled 1-2 weeks before the course examinations. Results: A positive but weak correlation was found between the overall quiz scores and exam scores when the two classes were combined (P<0.0001). A positive but weak correlation was likewise found between students' performance on exams and on in-class LC quizzes (class of 2016) (P<0.0001) as well as on exams and online LC quizzes (class of 2017) (P<0.0001). Conclusion: It is not just the introduction of technological tools that impacts learning, but also their use in enabling an interactive learning environment. The LC platform provides an excellent technological tool for enhancing learning by improving bidirectional communication in a learning environment.

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

Submandibular sialolithiasis with CT and scintigraphy: CT values and salivary gland excretion in the submandibular glands

  • Ogura, Ichiro;Hayama, Kazuhide;Sue, Mikiko;Oda, Takaaki;Sasaki, Yoshihiko
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: Sialolithiasis is one of the most prevalent large obstructive disorders of the submandibular glands. The aim of this study was to investigate submandibular sialolithiasis with computed tomography (CT) and scintigraphy, with a particular focus on the relationship between CT values of the submandibular glands and their excretion rate. Materials and Methods: Fifteen patients with submandibular sialolithiasis who underwent CT and salivary gland scintigraphy were included in this study. The relationship between the CT values of submandibular glands with and without sialoliths and salivary gland excretion measured using salivary gland scintigraphy was statistically analyzed. Dynamic images were recorded on the computer at 1 frame per 20 seconds. The salivary gland excretion fraction was defined as A (before stimulation test [counts/frame]) / B (after stimulation test [counts/frame]) using time-activity curves. Results: The CT values in the submandibular glands with and without sialoliths was $9.9{\pm}44.9$ Hounsfield units(HU) and $34.2{\pm}21.8HU$, respectively (P=.233). Regarding the salivary gland excretion fraction using scintigraphy, the A/B value in the submandibular glands with sialoliths ($1.09{\pm}0.23$) was significantly lower than in the submandibular glands without sialoliths($1.99{\pm}0.57$, P=.000). Conclusion: Assessments of the CT values and the salivary gland excretion fraction using scintigraphy in the submandibular glands seem to be useful tools evaluating submandibular sialolithiasis.