• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.025 seconds

STUDY ON THE PROPERTIES OF GYPSUM-BONDED DENTAL INVESTMENTS (치과용 석고계 매몰재의 특성에 관한 연구)

  • Kim, Kyoung-Sun;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.139-165
    • /
    • 1991
  • The properties of a investment material can be described by the consistency at the slurry state, the setting time, the compressive strength and the thermal expansion during the casting. In this study the effect of the production parameters which are included the ratio of quartz and cristobalite, the content of binder, the water powder ratio and the content and concentration of additives on the properties of the gypsum-bonded investments has been investigated with help of the consistency test, the vicat needle test, the compressive strength test, the thermal expansion test, x-ray diffraction and DTA thermal differential test. The experimental results showed that the constitution of a investment with W/P ratio of 0.34, 30% of gypsum, 0.8% aluminium sulfate, 2% magnesium sulfate, 0.6% sodium phosphate was adapted for the properties of the KDA Spec. No. 13 type I investment. The important experimental results are summarized as follows. 1. The consistency of the investment decreased with increasing amount of aluminium sulfate and decreasing amount of sodium phosphate. An addition of magnesium sulfate up to 2% an increase of the consistency was shown. But 3% magnesium sulfate in investment showed a decrease of consistency. The consistency did not vary significantly with a variation of the content of gypsum and cristobalite and the W/P ratio. 2. Aluminium sulfata and the magnesium sulfate promoted the hardening and the aluminium phoshpate delayed the hardening. The setting time increased with amount of gypsum. The effect of the matrix on the setting time was insignificant. With the W/P ratio of 0.34 the setting time was 14 min. 3. The compressive strength decreased with the amount of aluminium sulfate up to 0.25% and increased with the amount of aluminium sulfate greater than 3%. The compressive strength decreased as decreasing the amount of magnesium sulfate and gypsum and as increasing the W/P ratio. The effect fo the refractory on the compressive strength was also not significant. With the W/P ratio of 0.34 the compressive strength was $34Kg/mm^2$. 4. The 1st thermal expansion was found at the temperature near $250^{\circ}C$ and the steady state or the contraction stage was found at the temperature between $250^{\circ}C$ and $500^{\circ}C$. After this stage the 2nd thermal expansion took place at the temperature near $500^{\circ}C$. The amount of thermal expansion increased with decreasing the content of magnesium sulfate, aluminium sulfate and gypsum and the W/P ratio. And the amount of thermal expansion increased as the content of sodium phosphate ad cristobalite. With the W/P ratio of 0.34 the amount of total expansion was 1.2%.

  • PDF

Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis (유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석)

  • Kim, Kyung-Tak;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • Statement of problem: High stress concentration on the crestal cortical bone has been regraded as a major etiologic factor jeopardizing long term stability of endosseous implants. Purpose: To investigate if the design characteristics of crestal module, i.e. internal type, external type, and submerged type, affect stress distribution on the crestal cortical bone. Material and methods: A cylindrical shaped implant, 4.3 mm in diameter and 10 mm in length, with 3 different crestal modules, i.e. internal type, external type, and submerged type, were analysed. An axisymmetric scheme was used for finite elment formulation. A vertical load of 50 N and an oblique load of 50N acting at $45^{\circ}$ with the implant's long axis was applied. The peak crestal bone stress acting at the intersection of implant and crestal bone was compared. Results: Under vertical load, the crestal bone stress was high in the order of internal, external, and submerged types. Under the oblique loading condition, it was in the order of internal, submerged, and external types. Conclusion: Crestal module design was found to affect the level of the crestal bone stresses although the actual amount was not significant.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Study of chitosan's effects on periodontal tissue regeneration: a meta-analysis of the histomorphometry (키토산의 치주조직 재생력에 대한 연구의 고찰: 조직계측학적 메타분석)

  • Yang, Jin-Hyuk;Chae, Gyung-Joon;Yun, Jeong-Ho;Jung, Ui-Won;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • Purpose: Chitosan & chitosan derivative(eg. membrane) have been studied in periodontal regeneration, and recently many studies of chitosan have reported good results. If chitosan's effects on periodontal regeneration are enhanced, we can use chitosan in many clinical and experimental fields. For this purpose, this study reviewed available literatures, evaluated comparable experimental models. Materials and Methods: Ten in vivo studies reporting chitosan's effects on periodontal tissue regeneration have been selected by use of the 'Pubmed' and hand searching. Results: 1. In Sprague Dawley rat calvarial defect models, amount of newly formed bone in defects showed significant differences between chitosan/chitosan-carrier/chitosan-membrane groups and control groups. 2. In beagle canine 1-wall intrabony defect models, amount of new cementum and new bone showed significant differences between chitosan/chitosan-membrane groups and control groups. The mean values of the above experimental groups were greater than the control groups. Conclusion: The results of this study have demonstrated that periodontal regeneration procedure using chitosan have beneficial effects, which will be substitute for various periodontal regenerative treatment area. One step forward in manufacturing process of chitosan membrane and in use in combination with other effective materials(eg. bone graft material or carrier) may bring us many chances of common use of chitosan in various periodontal area.

THE EFFECT OF 1.23% APF GEL ON THE ESTHETIC RESTORATIVE MATERIALS (APF Gel이 심미 수복재료의 표면에 미치는 영향)

  • Choi, Won-Hyuk;Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.281-289
    • /
    • 2006
  • Topical fluoride application for children is a widely performed procedure in the field of Pediatric Dentistry for its dental caries prevention effects However, it is recently recognized as having some unwanted effects on several esthetic restorative materials, the author immersed glass ionomer cement, compomer and composite resin specimens in APF gel and measured the surface roughness and also, examined the specimens under the scanning eletron microscope. The followings are the results: 1. In the specimens of glass ionomer cement and compomer, APF gel 4 minute immersion group and pH cycling group show statistically significant increased surface roughness than artificial saliva immersion group (p<0.01). 2. There was no statistically significant surface roughness for composite resin in all group (p>0.05). 3. When the specimens were examined under scanning electron microscope, the surface change were in the order of glass ionomer cement, compomer, composite resin and also in the order of pH cycling group, APF gel 4 minutes immersion group, artificial saliva immersion group.

  • PDF

A Literature Review on Nano-Modified Implant Surfaces (나노구조 표면에 관한 문헌고찰)

  • Park, Go-Woon;Cha, Min-Sang;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.141-151
    • /
    • 2013
  • The nano-surface modification techniques could be classified; internal modifications which enhance surface roughness and porosity in nano level and external modifications as nano particle coating. Nano-modified implant surface has various morphograpies such as nanotube, nanopit, nanonodule and polymorphic structures. Creating surface depends upon preparation method and material, however, there is no standard preparation technique not yet. The nano-modified surfacet is electrochemically stable comparing with the surface modified in micron level. Nano-modified surface has little cytotoxicity, stimulates osteoblast proliferation and differentiation. Moreover, it decreases soft tissue intervention by interrupting the proliferation of fibroblast. Nanostructure has similar size and shape with cells and proteins, consequently leads to good biocompatibility and enhanced osseointegration. However, the actual effect in vivo is limited, due to the distance of effect. Even if nano-modified surface has antibiotic property due to photocatalysis, short duration time makes clinical application questionable. Further investigations should focus on the optimal nano-modified surface, which has many potentials.

SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS (Ormocer 계열 수복재의 물성에 관한 연구)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.362-370
    • /
    • 2002
  • During the last two decades, many new filling materials and material groups have been developed. the number of available restoratives has increased dramatically, especially during the last 5 years. Ormocers are a new class of materials which are still under development with regard to dental applications. However, in the chemical literature these materials have been known for a long time and used for producing scratch resistant coatings on plastic spectacle lenses. It is a combination of inorganic and organic materials. 'Ormocer' is an abbreviation for 'Organically Modified Ceramics'. These compounds are also known in the literature as 'Ormosils' (organically modified silicates). Their chemistry is comparable to that of silicones and organic polymers. The purpose of this study was to determine of compressive strength and flexural strength of a ormocer (Admira) and to investigate the effects of water absorption in comparison with three composite resins(Z-100, Tetric Ceram, Surefil) and one compomer(Dyract AP). The following results were obtained ; 1. Admira had the lower compressive strength than Surefil, but no statistically difference with other materials at 1 day(p>0.05). 2. Admira had the lower flexural strength than all other materials at 1 day. From 2 days, Admits showed lower flexural strength than three composite resin(p<0.05). 3. There was not statistically significant difference of compressive and flexural strengths between hybrid composite resin group(Z-100, Tetric Ceram) and Packable resin group(Surefil) for experimental period(30 days)(p>0.05). 4. All five materials showed an increase in compressive and flexural strength till 2 days and showed a decrease from 7 days in water(p<0.05). 5. Each materials had the statistically similar behavior of compressive and flexural strengths over time(p>0.05).

  • PDF

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

Micromorphology and Chemical Composition of a Sialolith in the Submandibular Gland Duct (악하선 내 타석의 미세형상 및 화학적 조성)

  • Im, Yeong-Gwan;Song, Ho-Jun;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.161-167
    • /
    • 2011
  • Sialolith is one of the most common pathologic conditions found in the salivary glands. The mechanisms responsible for the formation of sialoliths have not been elucidated so far. In this article, the chemical composition and micromorphology of a sialolith of a 58-year old female patient suffering from chronic sialoadenitis of the submandibular gland was analyzed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). In a SEM evaluation, the highly mineralized amorphous core surrounded by lamellar and concentric structures was revealed, however no foreign body, organic material, or signs of microorganism were observed in the core of the sialolith. EDX analysis showed the central core was composed of only Ca, O and P, and that a high level of C was detected near the central area as well. These results indicated that the inorganic composition of the sialolith was hydroxyapatite crystals, and that inorganic and organic substances existed around the central cores. This study suggests that the sialolith was composed mainly of hydroxyapatite crystals and the formation of the nucleus of the sialolith in the submandibular gland duct was secondary to sialadenitis, which favors the growth of an inorganic crystalline nucleus.

COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN (수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도)

  • Kim, Lae-Gyu;Chung, Moon-Kyu;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF