• 제목/요약/키워드: dental laser

검색결과 337건 처리시간 0.029초

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제43권4호
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.

임상가를 위한 특집 4 - CAD/CAM 시스템을 이용한 가철성 보철 수복 (The removable prosthetic restorations utilizing CAD/CAM system)

  • 박지만;박은진;김성균;곽재영;허성주
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.140-147
    • /
    • 2012
  • Recently, the digital solution of fabricating removable prosthesis by applying haptic input device, electronic surveying, and rapid prototyping was introduced. This review article covers the concept of electronic surveying, computer-aided denture framework designing procedure, discussions after several digital denture cases, directions of future development, such as digital tooth arrangement and RP flasking.

백서조골세포의 기능에 대한 저수준레이저의 효과 (Effects of Low-Level Laser Irradiation on the Rat Osteoblast Function)

  • Ki-Suk Kim;Jung-Keun Kim;Jung-Kun Kim;Masahru Shimizu
    • Journal of Oral Medicine and Pain
    • /
    • 제21권1호
    • /
    • pp.15-23
    • /
    • 1996
  • 저수준레이저조사 (low level lser irradiation, LLLI) 가 골형성을 자극한다고 보고되고 있지만 골아세포기능에 있어서 어떠한 역할을 하는지 별로 밝혀진 바가 없다. 본 연구에서는 백서 두 개관 조골세포양 세포(ROB)와 백서 조골세포주(ROS17/2.8)에 대한 저수준레이저의 효과를 조사하기 위하여 세포증식, alkaline phosphatase activity, 석회화 결질형성등을 관찰하였다. 두가지 배양 세포군에 저수준레이저를 조사한 결과 저수준레이저가 alkaline phosphatase activity를 증가시킬 뿐만 아니라 석회화 결절의 형성을 촉진하는 것을 볼 수 있었다. 이러한 결과로 보아 저수준레이저는 조골세포의 기능과 무기질침착을 자극함으로써 골형성을 촉진한다고 추정된다.

  • PDF

Hydroxyapatite Precipitation Phenomena on Micro-pore Formed Ti-Nb Alloy by PEO technique

  • Kim, Jeong-Jae;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.137-137
    • /
    • 2015
  • The purposed of this work was to observe hydroxyapatite precipitation phenomena on micro-pore formed Ti-Nb alloy by PEO technique. The Ti-30Nb and Ti-30Ta alloys were remelted at least ten times in order to avoid inhomogeneity, and then cylindrical specimens (diameter 10 mm, thickness 4 mm) were cut by using laser from cast ingots of the Ti alloys. Heat treatment was carried out at $1050^{\circ}C$ for 2 h for homogenization in argon atmosphere. The morphologic change of the alloys were examined by X-ray diffractometer (XRD) and field emission scanning electron microscopy (FE-SEM).

  • PDF

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구 (ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY)

  • 엄상호;오상천
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

3D-printed titanium implant with pre-mounted dental implants for mandible reconstruction: a case report

  • Park, Jung-Hyun;Odkhuu, Michidgerel;Cho, Sura;Li, Jingwen;Park, Bo-Young;Kim, Jin-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.28.1-28.4
    • /
    • 2020
  • Background: This clinical case presented a novel method of segmental mandible reconstruction using 3D-printed titanium implant with pre-mounted dental implants that was planned to rehabilitate occlusion. Case presentation: A 53-year-old male who suffered osteoradionecrosis due to the radiation after squamous cell carcinoma resection. The 3D-printed titanium implant with pre-mounted dental implant fixtures was simulated and fabricated with selective laser melting method. The implant was successfully inserted, and the discontinuous mandible defect was rehabilitated without postoperative infection or foreign body reaction during follow-ups, until a year. Conclusions: The 3D-printed titanium implant would be the one of the suitable treatment modalities for mandible reconstruction considering all the aspect of mandibular functions.

Apoptosis in the craniofacial tissues of irradiated growing rats

  • Heo Min-Suk;Choi Hang-Moon;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • 제31권4호
    • /
    • pp.227-233
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the apoptosis induction in tissues constituting the craniofacial region of growing rat by irradiation. Materials and Methods: The submandibular gland, brain, articular cartilage of condylar head, and calvarium were extracted from 20-day-old rats irradiated 10 Gy. Apoptosis of each tissue was examined by DNA fragmentation and estimated quantitatively using apoptotic index on TUNEL assay. Apoptotic index of each tissue was calculated by the equation for apoptotic cells/total cells × 1,000 on the images of confocal laser scanning microscopy. Apoptotic index was analyzed statistically according to the time lapse after irradiation on the tissues. Results : In the submandibular gland, apoptotic index was significantly increased from 6 hours after irradiation showing the highest value at 12 hours and decreased to the control level at 3 days after irradiation. In the brain, apoptotic index was abruptly reached to the maximum value at 6 hours after irradiation and decreased to the control level at 4 days after irradiation. Articular cartilage and calvarium showed no or little apoptotic signals. The results obtained by the apoptotic index accorded with that of DNA fragmentation. Conclusion : Radiation was closely related with the apoptosis of submandibular gland and brain but, not related with the apoptosis of the articular cartilage of condylar head and calvarium. The changes induced by radiation of the hard tissues would not be explained by apoptosis.

  • PDF

세륨옥사이드나노입자(Cerium oxide nano particles: CNPs)를 함유한 치면열구전색재의 Streptococcus mutans 부착량 변화 (Changes in the amount of adhesion of Streptococcus mutans to pit and fissure sealant incorporating cerium oxide nano particles(CNPs))

  • 이성숙;박영민;김동애
    • 한국치위생학회지
    • /
    • 제20권4호
    • /
    • pp.535-543
    • /
    • 2020
  • Objectives: The aim of this study was to investigated the surface roughness and change in the amount of adhesion of Streptococcus mutans to the commercial pit and fissure sealant containing cerium oxide nano particles(CNPs). Methods: The CNPs was incorporated into a commercial pit and fissure sealant at 0-4.0 wt%. Disk Specimens (ϕ 10 mm × 2 mm) were prepared by light polymerization the front and back for 40s. Average surface roughness was measured and Streptococcus mutans adhesion was observed under confocal laser scanning microscopy (CLSM) after 24 hour. Data were statistically analyzed by one-way ANOVA and Tukey HSDa post-hoc test. Results: Difference of the surface roughness(Ra) between groups was not statistically significant in both non CNPs group and CNPs group(p>0.05). In CNPs group, the amount of S. mutans adhesion was significantly different between control group and decreased in order of CNPs 4.0, CNPs 0.5, CNPs 1.0 and CNPs 2.0(p<0.05). Conclusions: Within the limitation of this study, these aspects of oral bacteria performances suggest potential usefulness of the CNPs incorporation, especially CNPs 1% and 2%, in pit and fissure sealant for inducing antibacterial effect.