ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구

  • Eom Sang-Ho (Department of Prosthodontics, College of Dentistry, Wonkwang University) ;
  • Oh Sang-Chun (Department of Prosthodontics, College of Dentistry, Wonkwang University)
  • 엄상호 (원광대학교 치과대학 치과보철학교실) ;
  • 오상천 (원광대학교 치과대학 치과보철학교실)
  • Published : 2005.08.01

Abstract

Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

Keywords

References

  1. Zarb GA, Bergman B, Clayton JA, MacKay HF. Prosthodontic Treatment for partially Edentulous Patients. The C.V. Mosby Co., Louis, 1978
  2. Eames WB, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression materials: effect of bulk on accuracy. J Prosthet Dent 1979 :41: 304-307 https://doi.org/10.1016/0022-3913(79)90013-1
  3. Clancy JM, Scandrett FR. Ettinger RL. Long-term dimensional stability of three current elastomers. J Oral Rehabil 1983; 10:323-325
  4. Lacy AM, Fukui H, Bellman T, Jendresen MD. Time-dependent accuracy of elastomer impression materials. Part II: Polyether. polysulfides. and polyvinylsiloxane. J Prosthet Dent 1981 :45:329-333 https://doi.org/10.1016/0022-3913(81)90400-5
  5. Myers GE, Stockman DG. Factors that affect the accuracy and dimentional stability of the mercaptan rubber-base impression materials. J Prosthet Dent 1960: 10:525-535 https://doi.org/10.1016/0022-3913(60)90016-0
  6. Stackhouse JA. The accuracy of stone dies made from rubber impression materials. J Prosthet Dent 1970:24:337-386
  7. Shigeto N. Murata H. Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet Dent 1989: 61 :54-58 https://doi.org/10.1016/0022-3913(89)90109-1
  8. American Dental Association. Vinyl polysiloxane impression materials: a status report. Council on Dental Materials. Instruments. and Equipment. J Am Dent Assoc 1990; 120: 595-596. 598, 600 https://doi.org/10.14219/jada.archive.1990.0077
  9. Paul J. Milward LCGI, William M. Murphy. Custom impression trays with a new hypo allergenic material. J Prosthet Dent 1994:72(5):572-573 https://doi.org/10.1016/0022-3913(94)90133-3
  10. Dong JK, Cho HW. Song DS. Kang SG. Development of dentulous stock trays for koreans. J Wonkwang Dental Research Institute 1995:5(3):85-124
  11. Dong JK, Jin TH, Song DS. A study on the fitness of stock tray in korean adults. J Korean Academy of Prosthodontics 1989: 27(2):131-140
  12. Dong JK, Oh SC, Park JY. Shin SJ. A study on the fitness of dentulous stock tray designed for koreans. J Wonkwang Dental Research Institute 1997; 7(1): 193-209
  13. Dong JK. Oh SC, Kim MJ. Development of adjustable dental impression trays. 10th Meeting of the International College of Prosthodontists, Canada Halifax. 2003:abstract No.51
  14. Craig RG.: Restorative Dental Materials. 10th. ed., The C.V. Mosby Co., Louis, 1997
  15. Shillingburg HT, Hatch RA, Keenan MP, Hemphill MW. Impression materials and techniques used for cast restoration in eight states. J Am Dent Assoc 1980: 100:696-699 https://doi.org/10.14219/jada.archive.1980.0228
  16. Craig, R.G.: Restorative Dental Materials. 7th. ed., The C.V. Mosby Co., Louis, 1985.
  17. Izharul Haque Ansari. Making a custom tray for elastomeric impression materials without a primary cast. J Prosthet Dent 1994: 72(5): 569-571 https://doi.org/10.1016/0022-3913(94)90132-5
  18. Reiberg HJ. The impression tray - an important factor in impression precision. Int Dent J 1977:27:146
  19. Breeding LC, Dixon DL, Monseley JP. Custom inpression trays part 1 : Mechanical properties. J Prosthet Dent 1994: 71: 31-34 https://doi.org/10.1016/0022-3913(94)90252-6
  20. Millstein P, Maya A. Segura C. Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil 1998: 25: 645-648 https://doi.org/10.1046/j.1365-2842.1998.00306.x
  21. Gordon GE, Johnson GH. Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 1990:63:12-15 https://doi.org/10.1016/0022-3913(90)90257-D
  22. Rueda LJ, Sy-Munoz JT, Naylor WP, Goodacre CJ, Swartz ML. The effect of using custom or stock trays on the accuracy of gypsum casts. lnt J Prosthodont 1996:9:367-373
  23. Boulton JL, Gage JP, Vincent PF, Basford KE. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J 1996:4:398-404
  24. Brosky ME, Pesun IJ, Lowder PD. DeLong R. Hodges JS. Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy. J Prosthet Dent 2002: 87: 204-209 https://doi.org/10.1067/mpr.2002.121240
  25. Brosky ME. Major RJ. DeLong R. Hodges JS. Evaluation of dental arch reproduction using three-dimensional optical digitization. J Prosthet Dent 2003:90:434-440 https://doi.org/10.1016/j.prosdent.2003.08.021
  26. Heartwell CM. Modjeski PJ. Mullins EE. Strader KH. Comparison of impression made in perforate and non perforated rimlock trays. J Prosthet Dent 1972;27:494-500 https://doi.org/10.1016/0022-3913(72)90261-2
  27. Mendez AJ. The influence of stone casts poured from irreversible hydrocolloid impressions. J Prosthet Dent 1985; 54: 383-388 https://doi.org/10.1016/0022-3913(85)90557-8
  28. Woodward JD. Morris JC. Zafrulla Khan. Accuracy of stone casts produced by perforated trays an nonperforated trays. J Prosthet Dent 1985;53:347-350 https://doi.org/10.1016/0022-3913(85)90508-6
  29. Valderhaug J. Floystrand F. Dimensional stability of elastomeric impression materials in custom-made and stock trays. J Prosthet Dent 1984:52:514-517 https://doi.org/10.1016/0022-3913(84)90336-6
  30. Johnson GH. Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and a repeat pour of models. J Prosthet Dent 1985: 53:484-490 https://doi.org/10.1016/0022-3913(85)90630-4
  31. Davis DR. Preble JS. Accuracy of a hydrophilic irreversible hydrocolloid/silicone impression material. J Prosthet Dent 1986: 55: 304-308 https://doi.org/10.1016/0022-3913(86)90108-3
  32. DeAraujo PA, Jorgensen KD. Effect of material bulk and undercuts on the accura-cy of impression materials. J Prosthet Dent 1985:54:791-794 https://doi.org/10.1016/0022-3913(85)90472-X
  33. Anusavice KJ. Phillips' science of dental materials. Elsevier. St Louis 1996,170
  34. Woodward JD, Morris JC, Kahn Z. Accuracy of stone cast produced by perforated trays and nonperforated trays. J Prosthet Dent 1985; 53: 347-350 https://doi.org/10.1016/0022-3913(85)90508-6
  35. Kaiser DA, Nicholls JI. A study of distortion and surface hardness of improved artificial stone casts. J Prosthet Dent 1976:36:373-381 https://doi.org/10.1016/0022-3913(76)90157-8
  36. Martinez LJ, von Fraunhofer JA. The effects of custom tray material on the accuracy of master casts. J Prosthodont 1998; 7: 106-110 https://doi.org/10.1111/j.1532-849X.1998.tb00188.x
  37. Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane put-ty-wash impression techniques. J Prosthet Dent 2000:83:161-165 https://doi.org/10.1016/S0022-3913(00)80007-4
  38. Valderhaug J, Floystrand F. Dimensional stability of elastomeric impression materials in custom-made and stock trays. J Prosthet Dent 1984: 52: 514-519 https://doi.org/10.1016/0022-3913(84)90336-6
  39. Dastane A, Vaidyanathan TK, Vaidyanathan J, Mehra R, Hesby R. Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces. J Oral Rehabil 1996:23:25-34 https://doi.org/10.1111/j.1365-2842.1996.tb00808.x
  40. Quick DC, Holton JR, Ross GK. Use of a scanning laser three-dimensional digitizer to evaluate dimensional accuracy of dental impression materials. J Prosthet Dent 1992:68:229-235 https://doi.org/10.1016/0022-3913(92)90319-6