• Title/Summary/Keyword: dental

Search Result 24,299, Processing Time 0.049 seconds

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Effect of polishing methods on color change by water absorption in several composite resins (여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향)

  • Kim, Hye Jin;Kim, Mi-yeon;Song, Byung-chul;Kim, Sun-ho;Kim, Jeong-hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

Sequential traction of a labio-palatal horizontally impacted maxillary canine with a custom three-directional force device in the space of a missing ipsilateral first premolar

  • Yang, Shuliang;Yang, Xiao;Jin, Anting;Ha, Nayong;Dai, Qinggang;Zhou, Siru;Yang, Yiling;Gong, Xinyi;Hong, Yueyang;Ding, Qinfeng;Jiang, Lingyong
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.124-136
    • /
    • 2019
  • Orthodontic treatment is more complicated when both soft and hard tissues must be considered because an impacted maxillary canine has important effects on function and esthetics. Compared with extraction of impacted maxillary canines, exposure followed by orthodontic traction can improve esthetics and better protect the patient's teeth and alveolar bone. Therefore, in order to achieve desirable tooth movement with minimal unexpected complications, a precise diagnosis is indispensable to establish an effective and efficient force system. In this report, we describe the case of a 31-year-old patient who had a labio-palatal horizontally impacted maxillary left canine with a severe occlusal alveolar bone defect and a missing maxillary left first premolar. Herein, with the aid of three-dimensional imaging, sequential traction was performed with a three-directional force device that finally achieved acceptable occlusion by bringing the horizontally impacted maxillary left canine into alignment. The maxillary left canine had normal gingival contours and was surrounded by a substantial amount of regenerated alveolar bone. The 1-year follow-up stability assessment demonstrated that the esthetic and functional outcomes were successful.

Prevalence and risk factors of peri-implantitis: A retrospective study (임플란트 주위염의 유병률 및 위험요소분석에 관한 후향적 연구)

  • Lee, Sae-Eun;Kim, Dae-Yeob;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Purpose: The study analyzed the prevalence of peri-implantitis and factors which may have affected the disease. Materials and methods: This study based on medical records and radiographs of 422 patients (853 implant cases) who visited Ewha Womans University Mokdong Hospital Dental Center from January 1, 2012 to December 31, 2016. Generalized estimation equations (GEE) was utilized to determine the statistical relationship between peri-implantitis and each element, and the cumulative prevalence of peri-implantitis during the observation period was obtained by using the Kaplan Meier Method. Results: The prevalence rate of peri-implantitis at the patient level resulted in 7.3% (31 patients out of a total of 422 patients), and at the implant level 5.5% (47 implants out of a total of 853 implants). Sex, GBR, guided bone regeneration (GBR) and functional loading periods had statistical significance with the occurrence of peri-implantitis. Upon analysis of the cumulative prevalence of peri-implantitis in terms of implant follow-up period, the first case of peri-implantitis occurred at 9 months after the placement of an implant, and the prevalence of peri-implantitis showed a non-linear rise over time without a hint of a critical point. Conclusion: The prevalence of peri-implantitis at the patient level and the implant were 7.3% and 5.5%, respectively. Male, implant installed with GBR and longer Functional Loading Periods were related with the risk of peri-implantitis.

Degree of Conversion and Polymerization Shrinkage of Low and High Viscosity Bulk-Fill Giomer-based and Resin-based composites (저점도 및 고점도 Bulk-fill Giomer 복합레진과 Bulk-fill 복합레진의 전환율과 중합수축)

  • Kim, Heera;Lee, Jaesik;Kim, Hyunjung;Kwon, Taeyub;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The aim of this study was to compare the degree of conversion and polymerization shrinkage of low and high viscosity bulk-fill giomer-based and resin-based composites. Two bulk-fill giomer (Beautifil Bulk Restorative (BBR), Beautifil Bulk Flowable (BBF)), two bulk-fill (Tetric N-Ceram Bulk-fill (TBF), SureFil SDR flow (SDR)) and two conventional resin composites (Tetric N-Ceram (TN), Tetric N-flow (TF)) were selected for this study. The degree of conversion was measured by using Fourier transform infrared spectroscopy. Polymerization shrinkage was measured with the linometer. For all depth, BBR had the lowest degree of conversion and SDR had the highest. At 4 mm, the degree of conversion of low and high viscosity bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). At the depth between 2 mm and 4 mm, there were significant difference with TBF, TN and TF (p < 0.05), while no significant difference in the degree of conversion was measured for BBR, BBF and SDR. Polymerization shrinkage of six resin composites decreased in the following order: TF > SDR > BBF > TBF > TN and BBR (p < 0.05). Polymerization shrinkage of bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). From this study, it is found that the bulk-fill giomer resin composites and TBF were not sufficiently cured in 4 mm depth. The degree of conversion of low and high viscosity bulk-fill giomer resin composites was significantly lower than bulk-fill resin composites in both 2 mm and 4 mm depths. Therefore, such features of bulk-fill giomer resin composites should be carefully considered in clinical application.

Down syndrome in women aged more than 35 Years positive detection rates (산전선별검사를 통한 35세이상 산모 다운증후군 양성률 비교 평가)

  • Oh, Taek Min;Kim, Ga-Yeon;Lee, Young ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.314-320
    • /
    • 2021
  • With the increasing age of motherhood in recent years, attributed to late marriages due to social or environmental factors, the Down's syndrome screening test using biochemical markers has become essential for pregnant women. The process of diagnosing Down's syndrome pregnancy in the high-risk group subjects involves chromosomal analysis, which is performed on samples obtained through invasive procedures such as chorionic biopsy or amniotic fluid. Thus, to reduce unnecessary invasive tests and lower the risk to mother and fetus, it is important to identify a screening test with low risk and high Down's syndrome detection rate. Recently, as the average age of mothers has increased, numerous inspection agencies have classified high-risk mothers as women over the age of 35 years. This study evaluated a total of 36,436 pregnant women aged between 17 to 46 years, and who requested prenatal screening at an inspection agency in Yongin in 2018. Test (13,690 people) Four tests were conducted by applying the time-resolved fluoroimmunoassay method using the direct sandwich and indirect sandwich technology, and the immunoassay method using the sandwich method. We aimed to confirm the difference in positivity rate with increasing age of the subjects. We believe that in future, data obtained from this study will be very useful for the prevention and treatment of Down's syndrome risk at varied inspection institutions, and for prospective mothers.

The control of TiO2 nanofiber diameters using fabrication variables in electrospinning method (전기 방사 공정의 제조 변수를 이용한 TiO2 나노섬유의 직경 제어)

  • Yoon, Han-Sol;Kim, Bo-Sung;Kim, Wan-Tae;Na, Kyeong-Han;Lee, Jung-Woo;Yang, Wan-Hee;Park, Dong-Cheol;Choi, Won-Youl
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • TiO2 has been used in various fields such as solar cells, dental implants, and photocatalysis, because it has high physical and chemical stability and is harmless to the body. TiO2 nanofibers which have a large specific surface area also show a good reactivity in bio-friendly products and excellent photocatalysis in air and water purification. To fabricate TiO2 nanofibers, an electrospinning method was used. To observe the diameter of TiO2 nanofibers with fabrication variables, the fabrication variables was divided into precursor composition variables and process variables and microstructure was analyzed. The concentrations of PVP (Polyvinylpyrrolidone) and TTIP (Titanium(IV) isopropoxide) were selected as precursor composition variables, and inflow velocity and voltage were also selected as process variables. Microstructure and crystal structure of TiO2 nanofibers were analyzed using FE-SEM (Field emission scanning electron microscope) and XRD (X-ray diffraction), respectively. As-spun TiO2 nanofibers with an average diameter of about 0.27 ㎛ to 1.31 ㎛ were transformed to anatase TiO2 nanofibers with an average diameter of about 0.22 ㎛ to 0.78 ㎛ after heat treatment of 3 hours at 450℃. Anatase TiO2 nanofibers with an average diameter of 0.22 ㎛ can be expected to improve the photocatalytic properties by increasing the specific surface area. To change the average diameter of TiO2 nanofibers, the control of precursor composition variables such as concentrations of PVP and TTIP is more efficient than the control of electrospinning process variables such as inflow velocity and voltage.

Ginseng Research in Natural Products Research Institute (NPRI) and the Pharmaceutical Industry Complex in Gaesong (생약연구소의 인삼연구와 약도개성)

  • Park, Ju-young
    • Journal of Ginseng Culture
    • /
    • v.3
    • /
    • pp.54-73
    • /
    • 2021
  • The Natural Products Research Institute (NPRI, 生藥硏究所), an institution affiliated with Keijo Imperial University (京城帝國大學), was the predecessor of the NPRI at Seoul National University and a comprehensive research institute that focused on ginseng research during the Japanese colonial era. It was established under the leadership of Noriyuki Sugihara (杉原德行), a professor of the second lecture in pharmacology at the College of Medicine in Keijo Imperial University. Prof. Sugihara concentrated on studying Korean ginseng and herbal medicine beginning in 1926 when the second lecture of pharmacology was established. In addition to Prof. Sugihara, who majored in medicine and pharmacology, Kaku Tenmin (加來天民), an assistant professor who majored in pharmacy; Tsutomu Ishidoya (石戶谷勉), a lecturer who majored in agriculture and forestry; and about 36 researchers actively worked in the laboratory before the establishment of the NPRI in 1939. Among these personnel, approximately 14 Korean researchers had basic medical knowledge, derived mostly from specialized schools, such as medical, dental, and pharmaceutical institutions. As part of the initiative to explore the medicinal herbs of Joseon, the number of Korean researchers increased beginning in 1930. This increase started with Min Byung-Ki (閔丙祺) and Kim Ha-sik (金夏植). The second lecture of pharmacology presented various research results in areas covering medicinal plants in Joseon as well as pharmacological actions and component analyses of herbal medicines. It also conducted joint research with variousinstitutions. Meanwhile, in Gaesong (開城), the largest ginseng-producing area in Korea, the plan for the Pharmaceutical Industry Complex was established in 1935. This was a large-scale project aimed at generating profits through research on and the mass production of drugs and the reformation of the ginseng industry under collaboration among the Gaesong Ministry, Kwandong (關東) military forces, Keijo Imperial University, and private organizations. In 1936 and 1938, the Gyeonggi Provincial Medicinal Plant Research Institute (京畿道立 藥用植物硏究所) and the Herb Garden of Keijo Imperial University (京城帝國大學 藥草園) and Pharmaceutical Factory were established, respectively. These institutions merged to become Keijo Imperial University's NPRI, which wasthen overseen by Prof. Sugihara as director. Aside from conducting pharmacological research on ginseng, the NPRI devoted efforts to the development and sale of ginseng-based drugs, such as Sunryosam (鮮麗蔘), and the cultivation of ginseng. In 1941, the Jeju Urban Test Center (濟州島試驗場) was established, and an insecticide called Pancy (パンシ) was produced using Jeju-do medicinal herbs. However, even before research results were published in earnest, Japanese researchers, including Prof. Sugihara, hurriedly returned to Japan in 1945 because of the surrender of Japanese forces and the liberation of Korea. The NPRI was handed over to Seoul National University and led by Prof. Oh Jin-Sup (吳鎭燮), a former medical student at Keijo Imperial University. Scholars such as Woo Lin-Keun (禹麟根) and Seok Joo-Myung (石宙明) worked diligently to deal with the Korean pharmaceutical industry.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.