Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance  

Choi, Woo Jeon (Department of Radiological Science, Busan BON Hospital)
Kim, Dong Hyun (Department of Radiological Science, Catholic University of Pusan)
Publication Information
Journal of the Korean Society of Radiology / v.13, no.4, 2019 , pp. 581-588 More about this Journal
Abstract
MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.
Keywords
Diamagnetic Materials; Magnetic susceptibility Artifacts; Metal Artifacts; Artifact Reduction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. M. Gunzinger, G. Delso, A. Boss, M. Porto, H. Davison, G. K. von Schulthess, I. A. Burger, “Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI,” EJNMMI physics, Vol. 1, No. 1, pp. 102, 2014.   DOI
2 R. H. Hashemi, G. William, J. Bradley, "Artifacts in MRI," MRI: the basics, pp. 185-213, 1997.
3 J. H. Cho, H. K. Lee, C. S. Prak, "The usability of the image according to the frequency encoding gradient direction conversion in fixation using the non magnetic metal screw," Journal of Digital Contents Society Vol. 12, No. 1, pp. 49-55, 2011.   DOI
4 C. A. Harris, L. M. White, “Metal artifact reduction in musculoskeletal magnetic resonance imaging,” Orthopedic Clinics, Vol. 37, No. 3, pp. 349-359, 2006.
5 A. Guermazi, Y. Miaux, S. Zaim, C. G. Peterfy, D. White, H. K. Genan, "Metallic artefacts in MR imaging: effects of main field orientation and strength," Clinical radiology, Vol. 58, No. 4, 322-328, 2003.   DOI
6 L. M. Tartaglino, A. E. Flanders, S. Viniski, D. P. Frideman, “Metallic artifacts on MR images of the postoeravtive spine: reduction with fast spine echo techniques,” Radiology, Vol. 190, No. 2, pp. 565-569, 1994.   DOI
7 C. A. Petersingle, J. S. Lewin, J. L. Duerk, J. U. Yoo, A. J. Ghanayeom, “Optimization of parameters for MR evaluation of the spine with titanium pedicle screws,” AJR American journal of roentgenology, Vol. 166, No. 5, pp. 1213-1218, 1996.   DOI
8 Z. H. Cho, Y. Ro, “Reduction of susceptibility artifact in gradient-echo imaging,” Magnetic resonance in medicine, Vol. 23, No. 1, pp. 193-200, 1992.   DOI
9 V. I. Frazzini, N. J. Kagetsu, C. E. Johnson, S. Destian, “Internally stabilized spine: optimal choice of frequency-encoding gradient direction during MR imaging minimized susceptibility from titanium vertebral body screw,” Radiology, Vol. 204, No. 1, pp. 268-272, 1997.   DOI
10 S. Vinitski, D. G. Mitchell, S. G. Einstein, “Conventional and fast spin echo MR imaging: minimizing echo time,” Journal of Magnetic Resonance Imaging, Vol. 3, No. 3, pp. 501-507, 1993.   DOI
11 L. Filli, L. Jud, R. Luechinger, D. Nanz, G. Andreisek, V. M. Runge, N. A. Farshad-Amacker, “Material-dependent implant artifact reduction using SEMAC-VAT and MAVRIC: a prospective MRI phantom study,” Investigative radiology, Vol. 52, No. 6, pp. 381-387, 2017.   DOI
12 B. Muller-Bierl, H. Graf, G. Steidle, F. Schick, “Compensation of magnetic field distortions from paramagnetic instruments by added diamagnetic material: measurements and numerical simulations,” Medical physics, Vol. 32, No. 1, pp. 76-84, 2005.   DOI
13 B. Chauvel, G. Cathelineau, S. Balac, J. Lecerf, J. D. De Certaines, “Cancellation of metal-induced MRI artifacts with dual-component paramagnetic and diamagnetic material: Mathematical modelization and experimental verification,” Journal of Magnetic Resonance Imaging, Vol. 6, No. 6, pp. 936-938, 1996.   DOI
14 A. P Rinck, E. Timothy Southon, "Magnetic Resonance in Medicine, 3rd Edition," pp. 5-18, 1993.
15 J. Starcukova, Z. Starcuk Jr, H. Hubalkova, “Magnetic susceptibility and elecrical conductivity of metallic dental materials and their impact on MR imaging artifacts,” Dental materials, Vol. 24, No. 6, pp. 715-723, 2008.   DOI
16 R. Bhagwandien, E. Van, R Beersma, C. J. Bakker, M. A. Moerland, J. J. W. Lagendijk, "Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 2D," Magnetic resonance imaging, Vol 10, No. 2, pp. 299-313, 1992.   DOI
17 F. ei Shafi, E. Honda, H. Takahashi, T. Sasaki, "Artifacts from dental casting alloys in magnetic resonance imaging," Journal of Dental Research. Vol. 82, No. 8, pp. 602-606, 2003.   DOI
18 L. F. C. Andre, A. Simone, Y. Clariss-Lin, "Artifacts in brain magnetic resonance imaging due to metallic dental objects," Med Oral Patol Oral Cir Bucal. Vol. 14, No. 6, pp. 278-282, 2009.
19 H. O. Song, "A Study on Metal Artifact Magnetic Resonance Image of Dental Orthodontic Fixture," Hanseo University, Master Thesis, 2013.
20 S. J. Kang, "A study on the reduction of the artifacts due to orthodontic devices in magnetic resonance imaging : evaluation and minimization of the artifacts depending on the arrangement of magnetic materials," Korea University, Matster Thesis, 2012.
21 M. F. Lee, S. Kim, “Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging multidetector CT,” Radio Graphics, Vol. 27, No. 3, pp. 791-803, 2007.
22 Y. H. Lee, D. Lim, E. Kim, S. Kim, H. Song, "Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T," Magnetic resonance imaging, Vol. 32, No 8, pp. 1001-1005, 2014.   DOI
23 Y. Gao, K. Muramatsu, A. Kushibe, K. Yamazaki, A. Chiba, T. Yamamoto, "Reduction of artifact of metallic implant in magnetic resonance imaging by combining paramagnetic and diamagnetic materials," Journal of applied physics. Vol. 107, No. 9, pp. 09B323, 2010.   DOI