• Title/Summary/Keyword: delta-V

Search Result 1,146, Processing Time 0.081 seconds

Comparison of Thermal Energy Harvesting Characteristics of Thermoelectric Thin-Film Modules with Different Thin-Film Leg Diameters (박막레그 직경에 따른 열전박막모듈의 열에너지 하비스팅 특성 비교)

  • Kim, Woo-Jun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.4
    • /
    • pp.67-74
    • /
    • 2018
  • Thermoelectric thin film modules were fabricated by electroplating p-type $Sb_2Te_3$and n-type $Bi_2Te_3$ thin film legs with the same thickness of $20{\mu}m$ and different diameters of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$, respectively. The output voltage and output power of thin film modules were measured and compared as a function of the leg diameter. The modules processed with thin film legs of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$-diameter exhibited open circuit voltages of 365 mV at ${\Delta}T=36.7K$, 142 mV at ${\Delta}T=37.5K$, and 53 mV at ${\Delta}T=36.1K$, respectively. Maximum output powers of $845{\mu}W$ at ${\Delta}T=36.7K$, $631{\mu}W$ at ${\Delta}T=37.5K$, and $276{\mu}W$ at ${\Delta}T=36.1K$ were obtained for the modules fabricated with the thin film legs of $100{\mu}m$, $300{\mu}m$, and $500{\mu}m$-diameter, respectively.

Degradation and Dielectric Properties of 22/154kV XLPE sheets (22/154kV급 XLPE의 유전특성과 절연열화)

  • Lee, Kwan-Woo;Lee, Jong-Bok;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.84-87
    • /
    • 2001
  • In this paper, degradation and dielectric properties of XLPE sheets moved from 22/154kV power cables were investigated. At the results of dielectric property of 22kV/154kV XLPE sheet, We earned that $tan{\delta}$ is $7.4{\times}10^{-4}$, $2.15{\times}10^{-4}$ and dielectric constant is 2.3, 2.24. Temperature dependance of $tan{\delta}$ inclined to increasing with temperature and increase of $tan{\delta}$ of 22kV XLPE sheet is higher than it of 154kV XLPE sheet. And increasement of XLPE sheet with water is higher than it without water.

  • PDF

VARIABLE STARS IN THE REGION OF CYG OB3 ASSOCIATION CENTERED ON THE OPEN CLUSTER NGC 6871 I: δ SCUTI TYPE STARS (산개성단 NGC 6871을 중심으로 한 Cyg OB3 성협 영역의 변광성 I: δ Scuti 형 변광성)

  • Jeon, Young-Beom;Lee, Uiryeol;Park, Yoon-Ho;Kim, Donghyeon;Jang, Hyeeun;Cho, Sungyoon
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.5
    • /
    • pp.399-409
    • /
    • 2012
  • As a part of the short-period variability survey (SPVS) at Bohyunsan Optical Astronomy Observatory, we obtained time-series BV CCD images in the region of Cyg OB3 association centered on the open cluster NGC 6871. The observations were performed for 18 nights from September 5, 2008 to September 1, 2009. We found 15 short-period variable stars in the region. They are ${\delta}$ Scuti type stars belonging to the local spiral arm, Orion spur. Among them, only two stars were previously known, and the rest are newly discovered ones. In this paper, we have performed a multiple-frequency analysis to determine frequencies of the 15 ${\delta}$ Scuti type stars, using the discrete Fourier transform and linear least-square fitting methods. One of the newly discovered variable stars is a double-mode ${\delta}$ Scuti type star with the fundamental and the first overtone modes, and two are high amplitude ${\delta}$ Scuti stars.

Leakage Current and Threshold Voltage Characteristics of a-Si:H TFT Depending on Process Conditions (a-Si:H TFT의 누설전류 및 문턱전압 특성 연구)

  • Yang, Kee-Jeong;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.737-740
    • /
    • 2010
  • High leakage current and threshold voltage shift(${\Delta}Vth$) are demerits of a-Si:H TFT. These characteristics are influenced by gate insulator and active layer film quality, surface roughness, and process conditions. The purpose of this investigation is to improve off current($I_{off}$) and ${\Delta}V_{th}$ characteristics. Nitrogen-rich deposition condition was applied to gate insulator, and hydrogen-rich deposition condition was applied to active layer to reduce electron trap site and improve film density. $I_{off}$ improved from 1.01 pA to 0.18 pA at $65^{\circ}C$, and ${\Delta}V_{th}$ improved from -1.89 V to 1.22 V.

Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity (소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화)

  • Oh, Sang-Yong;Kim, Jee-Won;Jung, Chang-Young;Kim, Kyung-Ah;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.540-547
    • /
    • 1993
  • Backgrounds: The measurement of volume of isoflow has been considered as a sensitive test for detecting small airway diseases showing normal pulmonary function in a routine pulmonary function test. To evaluate the functions of small airway among dust exposed workers, the changes of volume of isoflow were measured and its applicability of managing early stage pneumoconiosis patients was studied. Method: The subjects were 67 male, pneumoconiosis with small opacity and FEV1>80%, FEV1/FVC>75% in spirometry and the controls were 20 male, no dust-exposed office workers. The maximal epiratory volume curves after inhalation of indoor air and $He-O_2$ gas mixtures were measured and ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$ between the dust exposed and control workers were compaired. Results: 1) There were no significant differences between two group in ${\Delta}V_{max50}$ and ${\Delta}V_{max75}$. But the ratio of $V_{iso}V/VC$ of the subjects was siginificantly higher than that of the control (p<0.01). This study confirms that $V_{iso}V/VC$ is a very useful index in early detection of small airway dysfunction. 2) The ratio of $V_{iso}V/VC$ of the subjects was signigicantly different between only smoker group and mixed group(smoker and nonsmoker). It suggestes that smoking is an important cousative factor of small airway dysfunction. 3) As the profusion of the chest X-ray increased, the rartio of $V_{iso}V/VC$ increased, but no significant difference of $V_{iso}V/VC$ was found between categories of pneumoconiosis. The categories of pneumoconiosis and small airway dysfunction may not be related. 4) No significant relationship was established between the duration of work and the ratio of $V_{iso}V/VC$. Conclusions : It is concluded that the measurement of $V_{iso}V/VC$ is useful to detect small airway dysfuction of early stage pnuemoconiosis patents with small opacities but showing normal pulmonary function in a routine pulmonary function test.

  • PDF

Sintering Temperature Effect on Electrical and Dielectric Stability of ZPCCL-Based Varistors (소결온도가 ZPCCL계 바리스터의 전기적, 유전적 안정성에 미치는 영향)

  • Nahm, Choon-Woo
    • Korean Journal of Materials Research
    • /
    • v.16 no.8
    • /
    • pp.466-472
    • /
    • 2006
  • The electrical, dielectric properties, and its stability of ZPCCL-based varistors were investigated for different sintering temperatures in the range of $1230{\sim}1300^{\circ}C$. As the sintering temperatures increased, the varistor voltage decreased in the range of $777.9{\sim}108$ V/mm, the nonlinear coefficient decreased in the range of $77.9{\sim}7.1$, and the leakage current increased in the range of $0.3{\sim}50.6\;{\mu}A$. The stability of electrical and dielectric characteristics was obtained from sintering temperature of $1260^{\circ}C$. the varistors sintered at $1260^{\circ}C$ marked the high electrical and dielectric stability, with $%{\Delta}{V_{1mA}=+1.9%,\;%{\Delta}{\alpha}=-10.6%,\;%{\Delta}I_L=+20%\;and\;%{\Delta}tan\;{\delta}=+9.9%$ for DC accelerated aging stress state of $0.95V_{1mA}/150^{\circ}C$/24 h.

Enhancing hydrogen evolution activity of MoS2 basal plane by substitutional doping and strain engineering

  • Kim, Byeong-Hun;Lee, Byeong-Ju
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.280-284
    • /
    • 2016
  • 본 연구에서는 Density functional theory(DFT) 계산을 이용하여, $MoS_2$의 Mo와 S를 다른 원자로 치환 했을 때 $2H-MoS_2$ monolayer의 basal plane에서 HER활성을 향상시켰다. 특히 Ge와 Rh를 치환한 경우, ${\Delta}G_H$가 각각 0.03eV, 0,07eV로 최적에 가까운 HER활성이 나타났다. 다른 원자의 치환이 Fermi level 근처의 DOS(density of states)를 높여, ${\Delta}G_H$을 0에 가깝게 낮출 수 있음을 확인하였다. 또한 치환되는 원자의 농도, 그리고 strain을 변화시켜 농도와 strain의 증가에 따른 ${\Delta}G_H$ 감소를 발견했다. 이로써 각치환되는 원자마다, 치환 농도와 strain을 함께 변화시켜 ${\Delta}G_H$을 낮출 수 있었다. ${\Delta}G_H$가 0에 가까운(${\pm}{\pm}0.2eV$ 이내) 원자종류, 치환 농도, strain의 여러 조합을 찾았다.

  • PDF

A Study on current sensor (전류 검출기에 대한 연구)

  • Lee, Hwan
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.335-340
    • /
    • 1996
  • The item and structure of current detector depends on the current in conductors. The Hall current detector of these detectors is to use the variation of Hall voltage to conductor's current and it is very difficult for the conventional type to detect small current. In this paper we study experimented-method that detect AC current by using the magnetic modulation method the current, 0[mA]~100[mA]. The experiments results in 5 percent against the conventional, 20 percent in linear error, 0.12[.DELTA.mV/.DELTA.mA] to conventional type, 50[.DELTA.mV/.DELTA.mA] in sensitivity. (author). 7 refs., 15 figs.

  • PDF

Kinetics of the Reaction of Benzyl Chlorides with Pyridine in DMF under High Pressure (고압하에서 DMF 용매내에서 피리딘과 염화벤질류의 반응에 대한 속도론적 연구)

  • Kee Joon Choi;Young Hoon Lee;Jin Burm Kyong;Jeong Rim Kim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.291-296
    • /
    • 1988
  • Rates of the reaction for p-nitrobenzyl chloride, benzyl chloride and p-methylbenzyl chloride with pyridine in DMF solvent have been measured by an electric conductivity method at $40^{\circ}\;and\;50^{\circ}C$ under various pressures. From those rate constants, the activation parameters ${\Delta}V^{\neq},\;{\Delta}{\beta}^{\neq},\;{\Delta}H^{\neq},\;{\Delta}S^{\neq},\;{\Delta}G^{\neq}$) were evaluated. ${\Delta}V^{\neq}\;and\;{\Delta}{\beta}^{\neq}$ are both negative valued, but ${\Delta}H^{\neq}$ is positive and ${\Delta}S^{\neq}$ is large negative value. From the evaluation of the initial state and transition state which was resulted from substituents and pressure, it was found that this reaction proceeds through bimolecular reaction.

  • PDF

Natural Convection Heat Transfer in Rectangular Air Enclosures With Adiabatic and Isothermal Horizontal Boundary Conditions (단열 및 등온수평 경계조건을 갖는 직각 밀폐용기내 공기의 자연대류 열전달)

  • 이진호;김무현;모정하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.207-213
    • /
    • 1990
  • Natural convection heat transfer in rectangular air enclosure was studied interferometrically and numerically for the use of adiabatic and constant temperature horizontal boundary conditions. In the isothermal horizontal boundary case with the temperature difference ratio, .DELTA. $T_{v/}$.DELTA. $T_{H}$ .simeq. 1 temperature distribution in the enclosure is strongly stratified and the average Nusselt Number is higher than that of adiabatic horizontal boundary case.ase.