• Title/Summary/Keyword: delta-V

Search Result 1,146, Processing Time 0.026 seconds

The Effect of Cobalt Oxide Addition on Electrical and Dielectic Stability of Zinc Oxide Varistors (코발트 산화물 첨가가 산화아연 바리스터의 전기적, 유전적 안정성에 미치는 영향)

  • Nahm Choon-Woo;Yoo Dae-Hoon
    • Korean Journal of Materials Research
    • /
    • v.15 no.11
    • /
    • pp.722-729
    • /
    • 2005
  • The electrical and dielectric stability of zinc oxide-based varistors were investigated with the cobalt oxide contents in the range of $0.5\~5.0 mo\l%$. As cobalt oxide contents increased, the ceramic density increased in the range of $5.25\~5.55g/cm^3$ and the varistor voltage decreased in the range of $235.3\~86.0V$. The varistor with on addition of cobalt oxide $1.0 mol\%$ exhibited good nonlinearity. in which the nonlinear exponent is 66.6 and the leakage current is $1.2{\mu}A$. Furthermore, the varistors exhibited the highest electrical and dielectric stability, with $\%{\Delta}V_{1mA}=-1.9\%,\;\%{\Delta}{\alpha}=-10.5\%,\;\%{\Delta}I_L=+275.0\%,\;and\;\%{\Delta}tna{\delta}=+55.6\%$, under DC accelerated aging $0.95V_{1mA}/150^{\circ}C/24h$.

Preliminary Analysis of Delta-V Requirements for a Lunar CubeSat Impactor with Deployment Altitude Variations

  • Song, Young-Joo;Ho, Jin;Kim, Bang-Yeop
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.257-268
    • /
    • 2015
  • Characteristics of delta-V requirements for deploying an impactor from a mother-ship at different orbital altitudes are analyzed in order to prepare for a future lunar CubeSat impactor mission. A mother-ship is assumed to be orbiting the moon with a circular orbit at a 90 deg inclination and having 50, 100, 150, 200 km altitudes. Critical design parameters that are directly related to the success of the impactor mission are also analyzed including deploy directions, CubeSat flight time, impact velocity, and associated impact angles. Based on derived delta-V requirements, required thruster burn time and fuel mass are analyzed by adapting four different miniaturized commercial onboard thrusters currently developed for CubeSat applications. As a result, CubeSat impact trajectories as well as thruster burn characteristics deployed at different orbital altitudes are found to satisfy the mission objectives. It is concluded that thrust burn time should considered as the more critical design parameter than the required fuel mass when deducing the onboard propulsion system requirements. Results provided through this work will be helpful in further detailed system definition and design activities for future lunar missions with a CubeSat-based payload.

Electrical Characteristics of XLPE/Semicinductor Sheet for Power Cables (전력케이블용 가교 폴리에칠렌과 반도재료의 전기적 특성)

  • Paek, Kwang-Hyeon;Lee, Kyung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.142-145
    • /
    • 2004
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. studied effect for impurities and water for semiconductive shied through a dielectric properties experiment to estimate performance of insulating material in power cable. Capacitance and $tan{\delta}$ of 22[kV], 154[kV] were 52/42 pF and $7.4{\times}10^{-4}$, $2.1510^{-4}$, respectively. In these results, the trend was increased with the increase of temperature. The $tan{\delta}$ of XLPE/semiconductive layer and XLPE/water/semiconductive layer were increased as compared with that of XLPE. dielectric properties reliability of $tan{\delta}$ was small.

  • PDF

An Evaluation on Electrochemical Polarization Characteristics and Material Degradation for Cr-Mo-V Steel (Cr-Mo-V강의 전기화학적 분극 특성과 재질열화 평가)

  • Kwon, Il-Hyun;Lee, Song-In;Ha, Jeong-Soo;Yu, Hyo-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.267-274
    • /
    • 2002
  • This research is described on the applicability of a electrochemical techniques for evaluating nondestructive material degradation with various polarization characteristics for Cr-Mo-V steel. The applied electrochemical technique is anodic polarization test which are widely used to evaluate the corrosion rate and/or sensitization at depleted zone of strengthening elements mainly caused by thermal experience for stainless steels. The evaluation of material degradation is performed by small punch test which has been well known as micromechanics test method using specimen size of $10{\times}10{\times}0.5mm$. The 1,000hrs aged material at $630^{\circ}C$ shows the highest material degradation$({\Delta}[DBTT]_{SP})$, but the 2,000hrs and 3,000hrs aged materials show the decrease of ${\Delta}[DBTT]_{SP}$ as aging time increases. It is observed that the difference of current density $({\Delta}I_{FP}\;and\;{\Delta}I_{SP})$.

A Kinetic Study on the Solvolysis of Benzyl Chloride under High Pressure (고압하에서 염화벤질의 가용매분해반응에 대한 속도론적 연구)

  • Kwon, Oh-Cheun;Kyong, Jin-Burm
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.207-214
    • /
    • 1987
  • Rates of solvblysis of benzyl chloride in ethanol-water mixtures have been measured at 30 and $40^{\circ}C$ under various pressures up 1.6 kbar. The plots of 1n k as a function of pressure are fitted to a second order function in p, and values of ${\Delta}V^{\neq}$and ${\Delta}{\beta}^{\neq}$ are obtained from the results. Also the values of various pseudo thermodynamic quantities were evaluated from the rate constants. The relationships of the 1n k to $Q_w$ or 1n $C_w$ indicate that the reaction proceeds through $S_N1$ mechanism. A comparison between the present and the previous results gives that the increasing order of ${\mid}{{\Delta}V_0}^{\neq}{\mid}$ and n-values are $p-Cl>p-H>p-CH_3$ and $p-CH_3>p-H.p-Cl$, respectively. From these results, it is believed substituent such as the $p-CH_3$group favors the $S_N1(1)$ character, while the p-Cl group leads to the $S_N1(2)$ character.

  • PDF

EXISTENCE AND CONCENTRATION RESULTS FOR KIRCHHOFF-TYPE SCHRÖ DINGER SYSTEMS WITH STEEP POTENTIAL WELL

  • Lu, Dengfeng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.2
    • /
    • pp.661-677
    • /
    • 2015
  • In this paper, we consider the following Kirchhoff-type Schr$\ddot{o}$dinger system $$\{-\(a_1+b_1{\int}_{\mathbb{R^3}}{\mid}{\nabla}u{\mid}^2dx\){\Delta}u+{\gamma}V(x)u=\frac{2{\alpha}}{{\alpha}+{\beta}}{\mid}u{\mid}^{\alpha-2}u{\mid}v{\mid}^{\beta}\;in\;\mathbb{R}^3,\\-\(a_2+b_2{\int}_{\mathbb{R^3}}{\mid}{\nabla}v{\mid}^2dx\){\Delta}v+{\gamma}W(x)v=\frac{2{\beta}}{{\alpha}+{\beta}}{\mid}u{\mid}^{\alpha}{\mid}v{\mid}^{\beta-2}v\;in\;\mathbb{R}^3,\\u,v{\in}H^1(\mathbb{R}^3),$$ where $a_i$ and $b_i$ are positive constants for i = 1, 2, ${\gamma}$ > 0 is a parameter, V (x) and W(x) are nonnegative continuous potential functions. By applying the Nehari manifold method and the concentration-compactness principle, we obtain the existence and concentration of ground state solutions when the parameter ${\gamma}$ is sufficiently large.

Numerical solution for nonlinear klein-gordon equation by bollocation method with respect to spectral method

  • Lee, In-Jung
    • Journal of the Korean Mathematical Society
    • /
    • v.32 no.3
    • /
    • pp.541-551
    • /
    • 1995
  • The nonlinear Klein Gordon equation $$ (1) \frac{\partial t^2}{\partial^2 u} - \Delta u + V_u(u) = f $$ where $\Delta$ is the Laplacian operator in $R^d (d = 1, 2, 3), V_u(u)$ is the derivative of the "potential function" V, and f is a source term independent of the solution u, in various areas of mathematical physics.l physics.

  • PDF

The Characteristics of operating noises in the FBGA packages at high frequency (DRAM 패키지의 고주파 잡음 특성)

  • Kim, Joon-Il;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.487-488
    • /
    • 2006
  • In this paper, we analyzed the FBGA packages operating in high speeds and high frequency rates for DRAM. Using 3D simulations, we could extract s-parameters of packages. We realize that the proposed FBGA package does not operate properly at 3Gbps bacause the FBGA package have delta-I noise($V_{{\Delta}I-peak}$) of 132.0mV and crosstalk of 300mV, which is 25% of the operating clock level.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Robust algorithm for estimating voltage stability by the modified method of sensitivity index dP/de of real value on voltage vector (전압벡터의 유효분 감도지표 dP/de 수정법에 의한 견고한 전압안정도 평가에 관한 연구)

  • 송길영;김세영;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Recently, much attention has been paid to problems which is concerned with voltage instability phenomena and much works on these phenomena have been made. In this paper, by substituting d $P_{k}$ d $e_{k}$ ( $v^{\rarw}$= e +j f) for $P_{k}$ in conventional load flow, direct method for finging the limit of voltage stability is proposed. Here, by using the fact that taylor se- ries expansion in .DELTA. $P_{k}$ and .DELTA. $Q_{k}$ is terminated at the second-order terms, constraint equation (d $P_{k}$ d $e_{k}$ =0) and power flow equations are formulated with new variables .DSLTA. e and .DELTA.f, so partial differentiations for constraint equation are precisely calculated. The fact that iteratively calculated equations are reformulated with new variables .DELTA.e and .DELTA.f means that limit of voltage stability can be traced precisely through recalculation of jacobian matrix at e+.DELTA.e and f+.DELTA.f state. Then, during iterative process divergence may be avoid. Also, as elements of Hessian mat rix are constant, its computations are required only once during iterative process. Results of application of the proposed method to sample systems are presented. (author). 13 refs., 11 figs., 4 tab.

  • PDF