• 제목/요약/키워드: defect diagnosis

검색결과 450건 처리시간 0.022초

벨트 이송 시스템의 결함 진단을 위한 시뮬레이션 (Simulation for Defect Diagnosis in Belt Transport System)

  • 이남훈;유상헌;인용석;최연선;구자춘
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.366-371
    • /
    • 2006
  • As functional requirements of automatic office machines like printers, Automatic Tellex Machines(ATMs), copying machines are on a trend for the higher speed and precision, extensive technical advances are being developed and implemented in the industry. Media transport system is a device to convey a sheet of paper in ATMs and printers. The stability of media transport system is a matter of concern as their operating throughput rapidly increases. And defects of belts or rollers in a transport system directly affect the level of stability of the system. Therefore an automatic diagnostic system for predicting various defects is necessary for the stable operation of the media transport system. A simulation based on multi-body dynamics has been done for a feasibility study of a system design for the defect anticipation.

Neonatal Mitochondrial Respiratory Chain Defect and Vaginal Embryonal Rhabdomyosarcoma: Possibility of Oncogenesis?

  • ;;;;;이영목
    • 대한유전성대사질환학회지
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 2015
  • Mitochondrial disorders are rare metabolic diseases. They often present during neonatal period but with nonspecific clinical features such as feeding difficulties, failure to thrive, and seizures. Mitochondrial defects have also known to be associated with neurological disorders, as well as cancers. We report the first case of neonatal mitochondrial respiratory chain defect with sarcoma botryoides confirmed by pathologic diagnosis, suggesting another possible link between mitochondrial dysfunction and cancer.

유연매체 이송 시스템의 고장 진단을 위한 Simulation (Simulation for Automatic Diagnosis of Defect in Media Transport System)

  • 이남훈;유상헌;구자춘;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.564-568
    • /
    • 2005
  • As functional requirements of automatic office machines like printers, ATMs, copying machines are on a trend for the higher speed and precision, extensive technical advances are being developed and implemented in the industry. Media transport system is a device to convey a sheet of paper in ATMs and printers. The stability of media transport system is a matter of concern as their operating throughput rapidly increases. And defects of belts or rollers in a transport system directly affect the level of stability of the system. Therefore an automatic diagnostic system for predicting various defects is necessary for the stable operation of the media transport system. A simulation based on multi-body dynamics has been done for a feasibility study of a system design for the defect anticipation.

  • PDF

은닉 마르코프 모델을 이용한 질량 편심이 있는 회전기기의 상태진단 (Condition Monitoring Of Rotating Machine With Mass Unbalance Using Hidden Markov Model)

  • 고정민;최찬규;강토;한순우;박진호;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.833-834
    • /
    • 2014
  • In recent years, a pattern recognition method has been widely used by researchers for fault diagnoses of mechanical systems. A pattern recognition method determines the soundness of a mechanical system by detecting variations in the system's vibration characteristics. Hidden Markov model has recently been used as pattern recognition methods in various fields. In this study, a HMM method for the fault diagnosis of a mechanical system is introduced, and a rotating machine with mass unbalance is selected for fault diagnosis. Moreover, a diagnosis procedure to identity the size of a defect is proposed in this study.

  • PDF

유전성 대사질환의 착상전 유전진단 (Preimplantation Genetic Diagnosis in Inborn Error Metabolic Disorders)

  • 강인수
    • 대한유전성대사질환학회지
    • /
    • 제5권1호
    • /
    • pp.94-107
    • /
    • 2005
  • Prenatal diagnosis (PND) such as amniocentesis or chorionic villi sampling has been widely used in order to prevent the birth of babies with defects especially in families with single gene disorderor chromosomal abnormalities. Preimplantation genetic diagnosis (PGD) has already become an alternative to traditional PND. Indications for PGD have expanded beyond those practices in PND (chromosomal abnormalities, single gene defects), such as late-onset diseases with genetic predisposition, and HLA typing for stem cell transplantation to affected sibling. After in vitro fertilization, the biopsied blastomere from the embryo is analyzed for single gene defect or chromosomal abnormality. The unaffected embryos are selected for transfer to the uterine cavity. Therefore, PGD has an advantage over PND as it can avoid the risk of pregnancy termination. In this review, PGD will be introduced and application of PGD in inborn error metabolic disorder will be discussed.

  • PDF

차량탑재형 HFPD의 개발 (The Development of HFPD System for Mibile-loading Vehicles)

  • 김덕근;임장섭;여인선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

인가 스트레스에 따른 HFPD의 통계적 패턴해석 (Statistic Pattern Analysis of HFPD According to Applied Stress)

  • 김덕근;이은석;정영일;임장섭;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.18-22
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

PD 측정과 HFPD의 감도특성에 관한 연구 (A Study on the Sensitivities Characteristics in a PD and a HFPD)

  • 임장섭;김덕근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.29-32
    • /
    • 2000
  • The partial discharge testing is widely used in insulation property measurement because it gives low stress to high voltage equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power transformer that requires on-line & on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and PD/HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

회음부 괴사성 근막염후 발생한 요도 결손의 치료를 위한 음낭피부 종축관피판을 이용한 요도성형술 (Urethroplasty of Urethral Defect with Longitudinal Tubed Flap of Scrotal Skin after Fournier's Gangrene (Necrotizing Fascitis))

  • 민희준;노태석;김지예;김석원
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.667-670
    • /
    • 2010
  • Purpose: The management of urethral defect represents one of the most challenging clinical problems in uroplastic surgery. Especially for defect after Fournier's Gangrene, optimal management is still a hard problem. During extensive urethral reconstruction, to overcome the poor vascularity due to periurethral scarred tissue and limitation of the choice of local flap, we report our experience with one-stage reconstruction of urethral defect using a longitudinal tubed flap of scrotal skin. Methods: A 72-year-old man with several years of diabetes mellitus history visited for swelling and pain of scrotal area. After diagnosis of Fournier's Gangrene, radical debridement was performed and 6 cm of urethral defect on border of penile-scrotal ventral area was made. Rectangular scrotal skin flap ($6{\times}2.5\;cm$) based on external spermatic fascia was elevated and tubed longitudinally. After transfer the flap to the defect area, end-to-end anastomosis was performed bilaterally. Results: 4 weeks after the operation, the patient started voiding him-self and urethrography showed good fluence of contrast agent. Long term evaluation reveals stable performance characteristics without any complications. Conclusion: We suggest a one-stage reconstruction of extensive urethral defect using a longitudinal tubed flap of scrotal skin. Advantages of this procedures are simple, one-stage reconstruction with the reliable scrotal skin flap based on external spermatic fascial vasculature, and no donor morbidity.