• 제목/요약/키워드: dead load

검색결과 345건 처리시간 0.029초

강철도교에 대한 외부 후긴장 보강공법의 적용에 관한 연구 (A study on the Steel Plate Girder Railway bridge in the applying External Post-tensioning Method)

  • 최정열;박용걸;변종걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1034-1039
    • /
    • 2004
  • The major objective of this study is to investigate the effects and application of reinforcement for steel plate girder railway bridge by the external prestressing method. It analyzed the mechanical behaviors of non-ballasted railway bridge with ballast reinforced and external post-tensioning reinforced on the finite clement analysis for the static and dynamic behavior. As a result, the reinforcement of ballasted railway bridge the external prestressing method are obviously effective for the additional dead force which is ballast. The analytical study are carried out to investigate the post-tension force decrease bending behavior and deflection in composite bridge for serviceability. To develop two type FEM model which reflect well the post-tension force transverse distribution behavior of servicing bridge. With the comparing the results of railway bridge with ballast which carried out before the post-tensioning with the results of railway bridge with ballast which carried out after post-tensioning, It is investigated that the additional dead load decrease effect and bending behavior of servicing bridge is effect by the post-tensioning. The reinforcement by using the external tendon can be reducing that structure of a degradation phenomenon by unusual stresses due to additional dead load and other problems.

  • PDF

긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어 (Digital variable structure control of a hot-water heating control system with long dead time)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

유도전동기의 강인 속도 제어기에 관한 연구 (A Study on the Robust Speed Controller of Induction Motor)

  • 변황우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.612-615
    • /
    • 1997
  • In this paper, a robust speed controller considering the effect of uncertainty (plant parameter variation. external load disturbance. unmodeled and nonlinear dynamics etc..) for induction motor is proposed. Firstly. the dynamic model at nominal case of induction motor is estimated. Based on the estimated model. the IPSC ( Integral - Proportional Speed Controller) is designed. Then a DTRC (Dead-time Robust Controller) combining DTC ( Dead-time Compensator) & SRC (Simple Robust Controller) is designed to reduce the effects of parameter variation and external disturbance. Some simulated results are provided to demonstrate the effectiveness of the proposed controller.

  • PDF

사하중에 의한 정적 처짐을 고려한 보의 자유진동 (Free Vibrations of Beams with Static Deflections due to Dead Loads)

  • 이병구;박광규;오상진;모정만
    • 소음진동
    • /
    • 제4권4호
    • /
    • pp.451-457
    • /
    • 1994
  • A numerical method is presented to obtain natural frequencies and mode shapes of uniform elastic beams with static deflections due to dead loads. The differential equation governing the free vibration of beam taken into account the static deflection due to deal loads is derived and solved numerically. The hinged-hinged, clamped-clamped and clamped-hinged end constraints are applied in the numerical examples. As the numerical results, the lowest three nondimensional frequency parameters are reported as functions of nondimensional system parameters; the load parameters, and the slenderness rations. And some typical mode shapes of free vibrations are also presented in figures.

  • PDF

Efficiency Improvement of Synchronous Boost Converter with Dead Time Control for Fuel Cell-Battery Hybrid System

  • Kim, Do-Yun;Won, Il-Kuen;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1891-1901
    • /
    • 2017
  • In this paper, optimal control of the fuel cell and design of a high-efficiency power converter is implemented to build a high-priced fuel cell system with minimum capacity. Conventional power converter devices use a non-isolated boost converter for high efficiency while the battery is charged, and reduce its conduction loss by using MOSFETs instead of diodes. However, the efficiency of the boost converter decreases, since overshoot occurs because there is a moment when the body diode of the MOSFET is conducted during the dead time and huge loss occurs when the dead time for the maximum-power-flowing state is used in the low-power-flowing state. The method proposed in this paper is to adjust the dead time of boost and rectifier switches by predicting the power flow to meet the maximum efficiency in every load condition. After analyzing parasite components, the stability and efficiency of the high-efficiency boost converter is improved by predictive compensation of the delay component of each part, and it is proven by simulation and experience. The variation in switching delay times of each switch of the full-bridge converter is compensated by falling time compensation, a control method of PWM, and it is also proven by simulation and experience.

SVPWM 방식의 3상 인버터에 대한 간단한 데드타임 보상 알고리즘 (Dead Time Compensation Algorithm for the 3-Phase Inverter using SVPWM)

  • 김홍민;추영배;이동희
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.610-617
    • /
    • 2011
  • 본 논문은 공간벡터펄스 변조법(SVPWM, Space Vector Pulse Width Modulation)을 사용하는 3상 인버터의 새로운 데드타임 직접 보상 방법을 제안한다. 제안된 데드타임 보상방식은 인버터에 인가되는 데드타임을 중간상 전류의 방향에 따라, 유효전압이 인가되는 유효전압벡터 인가시간에서 직접 보상하는 방식이다. 3상 인버터에서 각상에 인가되는 전압의 크기는 유효전압이 인가되는 시간에 의해 결정되고, 데드타임의 영향에 따라, 실제로 유효전압이 인가되는 스위칭 시간은 전류의 방향에 따라 손실이 발생하게 된다. 제안된 방식에서는 실제로 전류의 방향에 따라 손실이 발생하는 유효전압벡터의 인가시간에 직접적으로 손실 시간을 더하여 유효전압벡터의 인가시간을 계산하는 방식으로 별도의 전압오차를 보상하기 위한 제어기와 복잡한 d-q 변환을 필요로 하지 않는 장점이 있다. 제안된 방식은 3상 R-L 부하에 대하여 컴퓨터 모의해석과 실험을 통하여 제안된 방식의 데드타임 보상을 검증하였다.

도로교 설계기준 및 AASHTO LRFD 설계기준에 근거한 U-채널 교량측보의 차량충돌의 영향 (Effect of Car-Crash at Edge Beam of U-Channel Bridge based on Korean Highway Bridge Specifications and AASHTO LRFD Bridge Design Specifications)

  • 최동호;나호성;이광원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.490-494
    • /
    • 2008
  • U-Channel Bridge is effective bridge type, because its edge beam performs role of barrier and enables to reduce additional dead loads. Although it is effective to reduce additional dead loads, there is possibility of bridge collapse under impact load due to car crash. Also, edge beam must have ability to induce safe driving and prevent falling accidents. Therefore, it requires behavior analysis and property investigation through the vehicle impact crashing edge beam. This study presents method of structural analysis of U-channel bridge and investigates design specifications for the effect of the edge beam under the vehicle impact. Also, it carries out stability investigation of behavior of edge beam and slab, based on Korean Highway Bridge Design Specifications and AASHTO LRFD Bridge Design Specification.

  • PDF

공진회로를 이용한 유도가열용 PWM 사이크로콘버터에 대한 고찰 (A Consideration of the PWM Cycloconverter with a Resonant Circuit for Induction Heating)

  • 김현중;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.509-511
    • /
    • 1994
  • Cycloconverters can be classified into two types by the main circuit configuration. One is the non- circulating current type required the dead time the other is circulating current type which has the circulating current reactors. The switching devices were highly stressed by the load voltages during dead time on non-circulating current type operation and the circulating currents on circulating current type operation. The overcome those problems, this paper proposes the switching patterns for the partial and the non circulation current type. The PWM methods, which are saw wave comparing method and load current integrating value comparing method, are presented.

  • PDF

교량부재의 사하중효과 및 저항의 확률적 특성 (Probabilistic Characteristics of Dead Load Effect and Resistance Variables for Bridge Members)

  • 정철헌;오병환
    • 콘크리트학회지
    • /
    • 제5권3호
    • /
    • pp.142-151
    • /
    • 1993
  • 교량 구조물의 안전성(신뢰성) 평가는 중요한 작업으로서, 교량 구조물의 안전성은 부재 단면의 저항과부재에 작용하는 외부하중에 의해서 결정된다. 부재의 강도는 부재를 구성하는 재료의 강도, 부재의 치수 및 단면으 저항을 계산하는 산정식등에 내재하는 오차등으로 인해서 공칭저항과 실제값과는 많은 차이가 발생하며, 교량 구조물에서 발생하는 사하중 모멘트는 해석변수와 단면 자중에 의한 하중변수에 의해서 영향을 받는다. 본 연구에서는 사하중효과의 부재 저항의 확률특성을 결정하기 위한 신뢰성 연구를 수행하기 위해서 이들 기본변수들에 대한 확률특성을 실측 및 실험자료를 통해서 우선적으로 평가하였다. 이들을 구성하는 각 기본변수들의 확률특성은 기존 연구결과 및 본 연구의 현장 실측 자료를 hd해서 결정하였다. 본 연구의 교량의 안전도 평가 및 교량의 신뢰성 해석을 합리적으로 수행할 수 있는 유용한 토대를 제공하는 것으로 사료된다.

저속 장행정 박용디젤기관의 속도제어에 관한 연구 (A STUDY ON THE SPEED CONTROL OF A LOW SPEED-LONG STROKE MARINE DIESEL ENGINE)

  • 유영호;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.26-36
    • /
    • 1989
  • Recently digital governor system is commonly adapted for the speed control of the marine diesel engine because of too much fluctuation of rpm resulted by the low speed, long stroke, high efficiency and a small number of cylinder of it, and versatile studies on the development of digital governor system are progressed. On this subject the new control method in which the fuel is controlled by feedforwarding the change of load as well as the feedback of angular velocity in case of disregarding the engine dead time and influence of scavenging air was proposed by the authors, and found the method has shown quite a good control performance in comparision to the conventional control method by the simulation using a digital computer for various load change. In this paper the speed control system of a diesel engine is simulated in case of regarding the engine dead time by the proposed method, and also confirm a good control performance of it under even more realistically simulated environment.

  • PDF