Discussions on the Cause of Mixed Gas Cylinder Rupture (혼합가스용기폭발 원인에 대한 고찰)

  • Yoon, Jae-Kun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.51-56
    • /
    • 2011
  • Mixed gas cylinder(80% Ar, 20% $O_2$) exploded three years ago. But the cause of cylinder rupture was not identified and the case was finished. This paper is the discussions on the cause of cylinder explosion with the investigation report by the police and the similar accident cases. The cause of explosion is the chemical reaction in the cylinder. This accident is similar with the explosion of pressurized oxygen cylinder.

Experiment and Simulation of Diffusion of Gas Released from the Relief Valve of a Gas Cylinder for a Portable Gas Range (압력 방출밸브를 장착한 이동식 부탄연소기용 부탄캔의 분출가스 확산 실험 및 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • In the last five years, 91 accidents from portable gas ranges and non-refillable metallic gas cartridges have occurred. The gas cylinder installed with a relief valve was developed to prevent an explosive accident from the gas cartridge. In this study it was carried out to evaluate the safety of a gas cylinder mounted with a relief valve which can prevent an explosion. Under the real using condition and the extreme condition the gas cylinder is heated with an electric heater. Simultaneously, the operating pressure is checked and the suitability of releasing flux is evaluated. And the possibility of fire or explosion was tested when the gas was released from the relief valve at the real using condition. Using a numerical simulation method, the diffusion of butane gas released from a relief valve was visualized.

A Study on Improving the Enhanced Durability of Cylinder Liner according to Cavitation Influence of Combat Equipment Engine (전투장비 엔진의 캐비테이션 영향에 따른 실린더 라이너의 내구성 강화 방안에 관한 연구)

  • Kim, Daeun;Lee, Kijung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.1-8
    • /
    • 2021
  • Cylinder liners used in diesel engines of combat equipment are prone to cavitation due to wet cooling. The damage caused by erosion and corrosion due to cavitation has a fatal effect on the performance and lifespan of a diesel engine. Therefore, a study was conducted to improve the durability of cylinder liners. Two surface treatment techniques were proposed: nitriding and chrome plating. It was observed that the amount of erosion on the surface of nitride-treated cylinder liners was high because the surface-treated part eroded due to its weak impact resistance against the bubble explosion generated by cavitation. In contrast, the chrome-plated cylinder liner had a lower amount of erosion among the specimens subjected to the accelerated test. These results verified that the resistance of chrome-plated liners against cavitation is high. Therefore, it can withstand the impact of bubble explosion. If the chrome plating thickness is set with reference to the KS standard, an exceptional durability of abrasion, wear resistance, and corrosion resistance can be obtained. If the thickness is set between 120~250㎛, it is expected that the durability of the cylinder liner can be improved. Although a recovery method for corroded cylinder liners is suggested, the proposed method has an inherent risk of crack generation. Therefore, further research is required to solve this problem.

High Vibration Phenomena due to Cylinder Explosion Pressure of Low-speed Diesel Engine with 7 Cylinders installed on Land (육상에 설치된 저속 7실린더 디젤엔진의 폭발 기진력 및 고진동 현상)

  • Kim, Yeon-Wahn;Bae, Yong-Chae;Bae, Chun-Hee;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.826-834
    • /
    • 2007
  • A 7K60MC-S low speed diesel engine in a power plant has frequently experienced high vibration since the unit completed construction works. Up to date, no fundamental vibration solutions were reached. Hence, several vibration tests and analyses were conducted to identify the root cause of this high vibration and to suggest the optimal countermeasures for diesel engine. The 9.25 Hz and 25.4 Hz vibrations have been observed on main body during operation. The magnitude of engine upper structural vibration is generally similar in horizontal transverse direction. However, differences in the 'Fore' and 'After' vibration magnitude with the same vibration phase angle at 9.25 Hz occur due to the explosion pulsations of 7 cylinders and the Inertia momentum added by the SCR (selective catalytic reduction) duct system. It was analyzed that the excess structural vibration occurred when the natural frequency of engine body is affected by the exciting sources due to the explosion pressure and the discharge pulsation of the seven cylinders in resonance range.

Underwater Explosion Experiments using Pentolite (펜톨라이트를 이용한 수중폭발 실험)

  • Choi, Gulgi;Jung, Keunwan;Jung, Son Soo;Kim, Jong-Chul;Lee, Phill-Seung
    • Explosives and Blasting
    • /
    • v.35 no.3
    • /
    • pp.21-30
    • /
    • 2017
  • When explosives explode in water, the effect of post-explosion gas after explosion should be considered, unlike explosion in the air. During explosion in water, the propagation velocity of the explosion pressure is faster than when the explosion occurs in the air. The generated gas is diffused and trapped in the form of bubbles by water before the energy is dissipated. At this time, the bubble expands and contracts, creating a shock wave. In order to investigate this series of phenomena, a cylinder type steel water tank capable of observing the interior was fabricated and explosion experiments were conducted. In this study, a small amount of shell-free pentolite was exploded in water. Experiments were performed to observe the behavior of the generated gas bubble as well as to measure the shock wave generated. We designed the experimental method of underwater explosion and examined the results.

Effect of Fluid Mesh Modeling on Surface Ship Shock Response under Underwater Explosion

  • Lee, Sang-Gab;Kwon, Jeong-Il;Chung, Jung-Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.351-358
    • /
    • 2001
  • In this study, for the investigation of effects of several parameters, such as fluid mesh boundary size, cylinder or block shape, dimensions of depth, breadth and length at free suface, and fluid mesh element size to the depth direction on a reliable shock response of finite element model under underwater explosion with consideration of the bulk cavitation analysis of a simplified surface ship was carried out using the LS-DYNA3D/USA code. The shock responses were not much affected by the fluid mesh parameters. The computational time was greatly dependent on the number of DAA boundary segments. It is desirable to reduce the DAA boundary segments in the fluid mesh model, and it is not necessary to cover the fluid mesh boundary to or beyond the bulk cavitation zone just for the concerns about an initial shock wave response. It is also the better way to prefer cylinder type of the fluid mesh model to the block one.

  • PDF

Analysis on the Explosion Risk Characteristic of Hydrogen blended Natural Gas (HCNG 혼합연료의 폭발 위험 특성 분석)

  • Kang, Seung-Kyu;Kim, Young-Gu;Kwon, Jeong-Rak
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2014
  • This study investigated the explosion characteristics of HCNG fuel using a simulation tool. The damage caused by the storage container explosion and vapor cloud explosion in a gas station was predicted. In case of an vapor cloud explosion in the HCNG station, 50~200kPa explosion pressure was predicted inside the station. When the cylinder explosion was occurred, in case of hydrogen, the measured influential distance of overpressure was 59m and radiant heat was 75m. In case of CNG, influential distance of overpressure was 89m and radiant heat was 144m would be estimated. In case of 30% HCNG that was blended with hydrogen and CNG, influential distance of overpressure was 81m and radiant heat was 130m were measured. The damage distance that explosive overpressure and radiant heat influenced CNG was seen as the highest. HCNG that was placed between CNG and hydrogen tended to be seen as more similar with CNG.

Development of the Safety Cabinet for Respiratory High-Pressure cylinder according to Consequence Analysis of Physical Explosion Damage (호흡용 고압용기 파열 피해영향 분석에 따른 안전충전함 개발)

  • Jang, Kap Man;Kim, Jeong Hwan;Jang, Yu Ri;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.80-88
    • /
    • 2016
  • A fire station and scuba have operated filling facilities for respiratory high-pressure cylinder without getting authority or reporting according to High-Pressure Gas Safety Control Act. They need facility improvement and special management to make provision for the time of accident during filling process. The Government have strived to correct illegal operations and suggested an alternative, establishing and operating the safety cabinet. It insures a safety being distance from danger caused by overpressure and a safety provoked by the protective wall equals or superiors. The safety cabinet is required to have an internal structure that smoothly distribute overpressure at the time of rupture. Plus, it needs to minimize fragments. It is also equipped with the performance of protective wall that makes overpressure to outside vent on the place where there is no person (top or bottom). This study calculated the consequence of physical explosion damage and built a prototype of safety cabinet. In addition, through the gas burst test, it derives for the ways to mitigate the physical explosion damage.

A Study for the Safety on the Flame Exposure of the Propane Cylinder (소형 프로판 용기의 화염 노출에 대한 안전성 연구)

  • Yim, Sang-Sik;Jang, Kap-Man;Lee, Jin-Han;Park, Gi-Dong;Kim, Ki-Bum
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.36-40
    • /
    • 2015
  • To evaluate the safety of propane cylinder, the flame test was performed by the flame exposure scenario of propane cylinder. The cylinder which was exposed in a flame was rapidly occurred to increase the internal pressure by liquid expansion, if so it cause of physical explosion. Therefore, the cylinder which was applied with thermal pressure relief device sholud be not bursted and the propane should be discharged to outside safely. The flame average temperature that was around of cylinder is $600^{\circ}C$, and then it increased $700^{\circ}C$ by discharged propane. The result of flame test, the cylinder was deformed, but it was not bursted. The regulations of flame exposure test for propane cylinder were not restricted, this paper can be applied to restrict the flame test if the cylinder is possible to expose the flame. Also, the results is expected as reference for estimation of the pressure cylinder performance.