A Trip Coil Fault Detection of Circuit Breaker (차단기 트립코일 이상감지 장치)

  • Youn, Ju-Houc;Lee, Jong-Hun;Park, Noh-Sik;Lee, Dong-Hea
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

Fast Scene Change Detection Algorithm in Compressed Video by a phased-approach Method (압축 비디오에서 단계적 접근방법에 의한 빠른 장면전환검출 알고리듬)

  • 이재승;천이진;윤정오
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.6 no.3
    • /
    • pp.115-122
    • /
    • 2001
  • A scene change detection is an important step for video indexing and retrieval. This paper proposes an algorithm by a phased algorithm for fast and accurate detection of abrupt scene changes in an MPEG compressed domain with minimal decoding requirements and computational effort. The proposed method compares two successive I-frames for locating a scene change occurring within the GOP and uses macroblock-coded type information contained in B-frames to detect the exact frame where the scene change occurred. The algorithm has the advantage of speed, simplicity and accuracy. In addition, it requires less amount of storage. The experiment results demonstrate that the proposed algorithm has better detection performance, such as precision and recall rate, than the existing method using all DC images.

  • PDF

The Value of Postoperative Serum Carcinoembryonic Antigen and Carbohydrate Antigen 19-9 Levels for the Early Detection of Gastric Cancer Recurrence after Curative Resection

  • Lee, Eung-Chang;Yang, Jun-Young;Lee, Kyung-Goo;Oh, Seung-Young;Suh, Yun-Suhk;Kong, Seong-Ho;Yang, Han-Kwang;Lee, Hyuk-Joon
    • Journal of Gastric Cancer
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 2014
  • Purpose: This study aimed to evaluate the value of serum carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA19-9) levels to detect gastric cancer recurrence. Materials and Methods: We retrospectively reviewed 154 patients who developed recurrence within 2 years after curative gastric cancer surgery and analyzed the relationship between postoperative CEA and CA19-9 levels and recurrence. We readjusted the cut-off values to improve the detection of recurrence. Subgroup analysis according to clinicopathologic variables was performed to further investigate the relationship between recurrence and CEA and CA19-9 levels. Results: The sensitivity and specificity for elevated CEA levels to detect recurrence were 40.6% and 89.5%, respectively, and those for CA19-9 were 34.2% and 93.6%, respectively. The sensitivity and specificity for elevation of either tumor marker were 54.3% and 84.0%, respectively; those for elevation of both tumor markers were 19.2% and 98.4%, respectively. By readjusting the cut-off values from 5.0 ng/ml to 5.2 ng/ml for CEA and from 37.00 U/ml to 30.0 U/ml for CA19-9, the sensitivity was increased from 34.2% to 40.2% for CA19-9, while there was no increase in sensitivity for CEA. In subgroup analysis, the sensitivity of CEA was higher in patients with elevated preoperative CEA levels than in patients with normal preoperative CEA levels (86.7% versus 33.7%; P<0.001). Furthermore, the sensitivity of CA19-9 was higher in patients with elevated preoperative CA19-9 levels than in patients with normal preoperative CA19-9 levels (82.61% versus 26.83%; P<0.001). Conclusions: CEA and/or CA19-9 measurement with the readjusted cut-off values allows for more effective detection of gastric cancer recurrence.

MPEG Video Segmentation using Two-stage Neural Networks and Hierarchical Frame Search (2단계 신경망과 계층적 프레임 탐색 방법을 이용한 MPEG 비디오 분할)

  • Kim, Joo-Min;Choi, Yeong-Woo;Chung, Ku-Sik
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.1_2
    • /
    • pp.114-125
    • /
    • 2002
  • In this paper, we are proposing a hierarchical segmentation method that first segments the video data into units of shots by detecting cut and dissolve, and then decides types of camera operations or object movements in each shot. In our previous work[1], each picture group is divided into one of the three detailed categories, Shot(in case of scene change), Move(in case of camera operation or object movement) and Static(in case of almost no change between images), by analysing DC(Direct Current) component of I(Intra) frame. In this process, we have designed two-stage hierarchical neural network with inputs of various multiple features combined. Then, the system detects the accurate shot position, types of camera operations or object movements by searching P(Predicted), B(Bi-directional) frames of the current picture group selectively and hierarchically. Also, the statistical distributions of macro block types in P or B frames are used for the accurate detection of cut position, and another neural network with inputs of macro block types and motion vectors method can reduce the processing time by using only DC coefficients of I frames without decoding and by searching P, B frames selectively and hierarchically. The proposed method classified the picture groups in the accuracy of 93.9-100.0% and the cuts in the accuracy of 96.1-100.0% with three different together is used to detect dissolve, types of camera operations and object movements. The proposed types of video data. Also, it classified the types of camera movements or object movements in the accuracy of 90.13% and 89.28% with two different types of video data.

Evaluation of measurement uncertainty for quantitative determination of chlorite and chlorate in fresh-cut vegetables using ion chromatography

  • Jung, Sungjin;Kim, Dasom;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Jung, Young Rim;Kim, Hekap
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.591-598
    • /
    • 2017
  • This study aimed to evaluate the measurement uncertainty for the quantitative determination of chlorite and chlorate in ready-to-eat fresh-cut vegetables using ion chromatography with a hydroxide-selective column. One gram of the homogenized sample in deionized water was sonicated and centrifuged at 8,500 rpm. The supernatant was purified by passing it through a Sep-Pak tC18 cartridge, followed by chromatographic determination using a Dionex IonPac AS27 column. The linearity of the calibration curves, recovery, repeatability, and reproducibility of the method were satisfactory. The method detection limit was estimated to be approximately 0.5 mg/kg. Each uncertainty component was evaluated separately, and the combined and expanded uncertainty values were calculated at the 95% confidence level. The measured concentrations for 3 mg/kg of chlorite and chlorate standard materials were $3.18{\pm}0.32$ and $3.10{\pm}0.42mg/kg$, respectively. These results confirmed the reliability of the developed method for measuring the two chlorine-based oxyanions in fresh-cut vegetables.

A Study on the Convergence Technique enhanced GrabCut Algorithm Using Color Histogram and modified Sharpening filter (칼라 히스토그램과 변형된 샤프닝 필터를 이용한 개선된 그랩컷 알고리즘에 관한 융합 기술 연구)

  • Park, Jong-Hun;Lee, Gang-Seong;Lee, Sang-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.1-8
    • /
    • 2015
  • In this paper, we proposed image enhancement method using sharpening filter for improving the accuracy of object detection using the existing Grabcut algorithm. GrabCut algorithm is the excellent performance extracting an object within a rectangular window range, but it has the drawback of the inferior performance in image with no clear distinction between background and objects. So, in this paper, reinforcing the brightness and clarity through histogram equalization, and tightening the border of the object using the sharpening filter look better than that extracted result of existing GrabCut algorithm in a similar image of the object and the background. Based on improved Grabcut algorithm, it is possible to obtain an improved result in the image processing convergence technique of character recognition, real-time object tracking and so on.

3D Conversion of 2D H.264 Video (2D H.264 동영상의 3D 입체 변환)

  • Hong, Ho-Ki;Baek, Yun-Ki;Lee, Seung-Hyun;Kim, Dong-Wook;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1208-1215
    • /
    • 2006
  • In this paper, we propose an algorithm that creates three-dimensional (3D) stereoscopic video from two-dimensional (2D) video encoded by H.264 instead of using the conventional stereo-camera process. Motion information of each frame can be obtained by the given motion vectors in most of videos encoded by MPEG standards. Especially, we have accurate motion vectors for H.264 streams because of the availability of a variety of block sizes. 2D/3D video conversion algorithm proposed in this paper can create the left and right images that correspond to the original image by using cut detection method, delay factors, motion types, and image types. We usually have consistent motion type na direction in a given cut because each frame in the same cut has high correlation. We show the improved performance of the proposed algorithm through experimental results.

Evaluation of Waist Circumference Cut-off Values as a Marker for Fatty Liver among Japanese Workers

  • Abe, Naomi;Honda, Sumihisa;Jahng, Doosub
    • Safety and Health at Work
    • /
    • v.3 no.4
    • /
    • pp.287-293
    • /
    • 2012
  • Objectives: Metabolic syndrome has received attention as a risk factor for cardiovascular disease, with particular importance attached to visceral fat accumulation, which is associated with lifestyle-related diseases and is strongly correlated with waist circumference. In this study, our aim is to propose waist circumference cut-off values that can be used as a marker for fatty liver based on a sample of workers receiving health checkups in Japan. Methods: This study was conducted in a total of 21,866 workers who underwent periodic health checkups between January 2007 and December 2007. The mean age of the subjects was 47.4 years for men (standard deviation [SD]: 8.0) and 44.7 years for women (SD: 6.9). Evaluation included abdominal ultrasound and measurement of waist circumference, body mass index, fasting blood glucose, triglycerides, high-density lipoprotein cholesterol, and blood pressure. Results: Based on receiver operating characteristic curve analysis, the optimal waist circumference cut-off values were shown as 85.0 cm (sensitivity 0.72, specificity 0.69) for men and 80.0 cm (sensitivity 0.75, specificity 0.78) for women. Conclusion: Abdominal ultrasound is the most efficient means of diagnosing fatty liver, but this examination seldom occurs because the test is not routinely performed at workers' health checkups. In people found to have a high risk of fatty liver, recommendations can be made for abdominal ultrasound based on the waist circumference cut-off values obtained in this study. That is, waist circumference can be used in high risk individuals as an effective marker for early detection of fatty liver.

Determination of dichloroacetic acid and trichloroacetic acid in fresh-cut salads using gas chromatography-mass spectrometry (GC-MS를 이용한 신선편의 샐러드 중 dichloroacetic acid와 trichloroacetic acid의 분석)

  • Kim, Hekap;Lee, Seong-gyun;Yun, A-hyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.1
    • /
    • pp.12-17
    • /
    • 2019
  • Dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in fresh-cut salads available from the market were determined by gas chromatography-mass spectrometry (GC-MS). The target compounds in 3 g of acidified homogenates were extracted with 20 mL of methyl t-butyl ether (MTBE). The extract was concentrated to 1 mL and heated for 1 h at $55^{\circ}C$. The analytes were separated using a DB-1701 column and detected with a mass spectrometer. The method detection limit was approximately $6{\mu}g/kg$, and both analytical accuracy and precision were found to be satisfactory. The linearity of the calibration curves expressed as the coefficients of determination was >0.996. The analysis of seven samples using the established method showed that the four samples contained considerable amounts of analytes ($25.4-31.2{\mu}g/kg$ of DCAA and $18.8-46.1{\mu}g/kg$ of TCAA). These results raised a concern about the impact of fresh-cut salad consumption on human health.

Comparison of pooled Versus Individual Sera in Avian Infectious Bronchitis Virus Seroprevalence Study (닭 전염성 기관지염 바이러스의 혈청 유병률 연구에서 개별혈청과 합병혈청의 비교)

  • Kim, Sa-Rim;Kwon, Hyuk-Moo;Sung, Haan-Woo;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.416-420
    • /
    • 2006
  • Compare to testing sera individually, pooled-serum testing has considered as a cost-effective method, particularly on a large population-based seroprevalence studies. This study was to determine the relationship between individual sera and pooled sera titers for detection of avian infectious bronchitis virus (IBV) and to evaluate suitability of pooled sera by comparing prevalences estimated from both samples. A total of 5,000 individual samples were collected from 500 flocks in Chungcheong, Gyunsgi, and Kangwon provinces between January 2005 and February 2006. Ten samples were randomly selected from each flock. Five-hundred pooled sera were prepared by mixing equal amount of each 10 individual serum from the original samples. IBV antibody titers were measured by hemagglutination inhibition (HI) test. The least squares regression analysis was performed to construct equation between pooled and mean individual titers. To determine whether the flock is infected 4 arbitrary criteria were used: detection of at least 1 chicken with HI titer ${\ge}$ 9 (criterion 1), detection of at least 2 samples with HI titer ${\ge}$9 (criterion 2), detection of at least 1 sample with HI titer ${\ge}$ 10 (criterion 3), and filially detection of at least 1 sample with HI titer ${\ge}$ 11 (criterion 4). The receiver operating characteristic (ROC) curve was used to examine the cut-off points of pooled titers showing optimal diagnostic accuracy. The area under the curve (AUC), sensitivities (Se), specificities (Sp), and positive (PPV) and negative (NPV) predictive values were calculated. The regression equation between pooled titers (pool) and mean individual titers (mean) was: $pool= 1.2498+0.8952{\times}mean$, with coefficient of determination of 87% (p< 0.0001). The optimal cut-off points of pooled titers were titer 8 for criterion 1 (AUC=0.975, Se=0.883, Sp=0.959, PPV=0.985, NPV=0.728), titer 8 for criterion 2 (AUC=0.969, Se=0.954, Sp=0.855, PPV=0.926, NPV=0.907), titer 9 for criterion 3 (AUC=0.970, Se=0.836, Sp=0.967, PPV=0.978, NPV=0.772), and titer 9 for criterion 4 (AUC= 0.946, Se=0.928, Sp=0.843, PPV=0.857, NPV=0.921). The difference of 'prevalence estimated by individual and pooled sample showed a minimum of 2% for criteria 2 and a maximum of 9.1:% for criteria 3. These results indicate that the use of pooled sera in HI test for screening IBV infection in laying hen flocks is considered as a cost-effective method of testing large numbers of samples with high diagnostic accuracy.