• Title/Summary/Keyword: curtain wall

Search Result 239, Processing Time 0.022 seconds

Study on Evaluation Analysis on Thermal Performance of Window Using A. S. Lab.(Artificial Solar Laboratory) (인공태양실험실(A. S. Lab.)을 활용한 창호의 열성능 평가에 관한 연구)

  • Kang, Ki-Nam;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.812-819
    • /
    • 2010
  • Recently residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. Along this the increased size and transparency of window as well as light surface caused by high stories lowers the heat shield efficiency of building. Since glass that constitutes building surface has low heat efficiency, it aggravates heat loss of all building considerably, thereby resulting in extreme heating load and cooling load in the country where temperature varies much in summer and winter. The research will check whether experiment can be effectively done by overcoming the limit of existing artificial solar laboratory constructed in the country and properly adjusting controlled variables with simplified function through construction of this experimental set.

Evaluation of Lighting Environment about the Characteristics of Shading Device (차양장치 특성에 따른 조명환경 평가)

  • Hong, Seong-Kwan;Lim, Ji-Sun;Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop;Kwun, Joon-Bum
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.153-156
    • /
    • 2008
  • According to the conversion of building into skyscraper, most buildings have curtain wall structures, so the shading device of building is required. The types of shading systems are a roller shade, venetian bind, and vatical blind and so on. A miler shade is mostly used among the shading systems. An experimental evaluation was verified whether there was an effect of shading materials(Perforated panel, Fabric) in each condition by an experiment with artificial lighting and daylight.

  • PDF

A Research on the Automatic Management System of Curtain Wall & Window Using Sensor (센서를 활용한 커튼&창문의 자동관리 시스템 연구)

  • Lee, Chang-uk;Lee, Sang-yoon;Lim, Seong-gyn;Kim, Geun-ho;Kim, dong-il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.410-412
    • /
    • 2017
  • The sensors can be operated and controlled anywhere, anytime, anywhere, via Arduino, an open source computing platform, through aduino, an open-source computing platform.

  • PDF

Experimental Study on the Evaluation of Heat Transfer Characteristics of Buildings' External Walls -Focusing on the winter heat transfer characteristics of four experimental model buildings in accordance with the location of insulation- (건물(建物) 외벽(外壁)의 전열특성(傳熱特性) 평가(評價)에 관한 실측(實測) 연구(硏究) - 단열재 위치에 따른 실험용 건물의 겨울철 열특성 평가를 중심으로 -)

  • Sohn, J.Y.;Yoon, D.W.;Park, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.228-234
    • /
    • 1989
  • This paper describes the experimental thermal performance results of four experimental model buildings insulated differently. For the purpose of examining the thermal characteristics of external walls and indoor thermal conditions, four experimental model buildings are constructed as externally insulated, internally insulated, non-insulated &light-weight curtain wall types with different K-values and heat capacities, respectively.
    Through the measurements of temperatures at various points and solar insolation, the effects of insulation and heat capacities are evaluated, and the evaluated effects of each experimental model buildings are compared. Hence, the characteristics of temperature profiles, time-lag effects and decrement factors are discovered.

  • PDF

A study on the Exterior materials of Super High Rise Housing in New York City (뉴욕시 초고층주거 외장재 연구)

  • 신수현
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.97-102
    • /
    • 2002
  • The Purpose of this study was to investigate the exterior materials of super high-rise housing more than 30 stories which were built in New York City between 1924 and 2004. The result of examining 153 buildings was as follows; Exterior materials of super high-rise housing which were used bricks, of the salt-glazed bricks, terra-cotta and ceramic tiles, jumbo bricks and bricks were preferred among them. The colour of bricks was yellow, yellow ochre, clear brown, brown, dark brown, orange, vermilion and red. Exterior materials of super high-rise hotel and hotel apartment were bricks and ceramic tiles in the early days but stones, curtain wall and glass(green glass, green-tinted glass, brown-tinted glass, black glass) after 1980s. The main colour of buildings extended gray, green, blue-tinted brown-tinted and black.

  • PDF

A Comparative Analysis of Energy Simulation Results and Actual Energy Consumption on Super High-rise Apartments (초고층 공동주택의 세대별 냉난방부하 시뮬레이션 결과 및 에너지 실사용량과의 비교 분석)

  • Suh, Hye-Soo;Kim, Byung-Seo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.34-40
    • /
    • 2011
  • Apartment Housing has been increasing steadily, particularly our current super high-rise apartment houses that represent the culture has become a trend in Korea. These super high-rise apartment houses' curtain wall system increases heating and cooling loads, it is expected to vary by each unit's thermal properties. In this study, measured indoor environment and energy simulation results were compared to actual energy consumption. As a result, the various factors that affect heating and cooling loads, such as direction, plan type and glazing area, influence each unit's load characteristic. In particular, according to the electricity costs savings behavior, the occupant's thermal discomfort is expected to be large in summer. Therefore, to reduce heating and cooling load for each unit requires a reasonable plan.

Efficiency Improvement for Building Integrated Photovoltaic Applied to High-rise Building (고층 빌딩에 적용되는 빌딩통합형 태양광패널 효율성 개선방안)

  • Lee, Do-Hyun;Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2022
  • With the advent of cutting-edge technology, renewable energy is significantly considered as alternative resources to supply electric power. However, many barriers such as energy intermittency, high initial installation cost, and low-efficiency generation challenged building new infrastructure with clean energy. Efforts reducing greenhouse gas emissions and reliance on fossil fuels resulted in the decentralization of power generation like distributed energy resource (DER). This paper is to introduce and evaluate the feasibility of building-integrated photovoltaics (BIPV) in a high-rise building in Ulsan. To optimize BIPV, a variety of methods to minimize efficiency decrease and maximize electric power generation after installing BIPV on the building's facade are suggested. The variables causing power losses are analyzed. By utilizing System Advisor Model (SAM), actual power generated from solar panels is measured by Thin-film PV, Mono-crystalline PV, and Poly-crystalline PV.

The Sensitivity Analysis of Thermal Expansion Breakage of Multi-layer Glazing in Building Envelope (건물 외피에 적용된 복층창의 열팽창 파손에 대한 민감도 분석 연구)

  • Yoon, Jong-Ho;Kim, Seung-Chul;Im, Kyung-Up;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.93-97
    • /
    • 2014
  • Curtain wall system of office buildings has recently become very common in Korea. As the multi-layer curtain glazing is exposed to outdoor environment, it is very subjected to direct environmental impact. Consequently, breakage and cracks of glazing due to heat expansion is frequently observed. This study explores various causes and aspects for destruction of multi-layer glazing. A sensitivity analysis was performed on the basis that thermal changes causes damage to the multi-layer glazing. Air temperature in air cavity within the multi-layer glazing was examined to find its effect on multi-layer glazing breakage. Analysis showed high deflection to depth ratio of 1:1.8 and that higher the aspect ratio, smaller is the deflection. Allowable pressure showed that the weakest value is for aspect ratio of 1:2.9. Sensitivity analysis by the area of the glazing showed that as area of glazing becomes higher, allowable pressure and deflection-depth ratio becomes smaller. For allowable pressure and allowable deflection-depth within air cavity, the glazing breakage occurred at least $107^{\circ}C$. The results from glazing breakage by thermal factor shows that it is hard to break the glazing with only an increase in air cavity temperature in multi-layer glazing applied in buildings.

Reflection and Transmission of Regular Waves by Multiple-Row Curtainwall-Pile Breakwaters (다열 커튼월-파일 방파제에 의한 규칙파의 반사 및 투과)

  • Suh, Kyung-Duck;Ji, Chang-Hwan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.2
    • /
    • pp.97-111
    • /
    • 2006
  • Using the eigenfunction expansion method, a mathematical model has been developed to calculate the reflection and transmission of regular waves from a multiple-row curtainwall-pile breakwater. In addition, hydraulic model experiments have been conducted with different values of porosities between the piles, drafts of the curtain walls, and distances between the rows of the breakwater. It is found that the reflection and transmission coefficients decrease and increase, respectively, with decreasing relative water depth, but they bounce to increase and decrease, respectively, as the relative water depth decreases further. When either the porosity between the piles or the draft of the curtain wall is changed with other parameters fixed, the relative magnitudes of the reflection and transmission coefficients have been changed, but the general trend remained the same. When the wavelength is the same as the distance between the rows of the breakwater, a rapid change was observed for the reflection and transmission coefficients. A good agreement between the measurement and prediction was also founded for three-row breakwaters.

Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(II) -Effects of the Thermal Curtain on Energy Preservation and Review of its Application- (간역잠실(簡易蠶室)의 난방부하특성(暖房負荷特性) 및 보온(保溫)커튼 설치(設置)효과에 관한 연구(硏究)(II) -보온(保溫)커튼의 열(熱) 절감(節減) 효과(効果) 및 적응성(適應性) 검토(檢討)-)

  • Choe, K.J.;Jung, D.H.;Park, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 1991
  • One of the most serious problems in Korean sericulture farms is to improve the adiabatic conditions for the simple silkworm rearing houses which has been widely adapted since early 1980'. Thus, this study is aimed to solve the problems by selecting the thermal screen material and by finding the method of its instalation. For the study, 4 kinds of materials which are (1) TE005,(2) NW60, (3) NW300 and (4) AL110 are selected and 4 different types of methods which are surrounding boundary of rearing bed(type A), surrounding inside of wall and ceiling (type B), installing on inside of wal ony (type C) and installing on ceiling Inly (type D) are installed. Decision criteria of the best combination of screen material and installation methods is made by calculating the heating load coefficients and by testing the application at the simple silkworm rearing houses. The obtained results are summarized as follows ; 1. The effect of thermal screen on reducing the thermal energy is remarkable. It saves energy more 50% than unscreened simple silkworm rearing houses. 2. From a stand point of a good screed material on thermal energy reduction, the NW300, AL110 and PE005 are recommanded materials. However, NW60 and PE005 are regarded as desirable materials from the practical point view. 3. Also, the effect on thermal energy reduction is largely affected by the method of thermal screen installation. The surrounding boundary of the silkworm rearing bed(type A) is the most desirable method to reduce the energy, which saves 56.6% of it. 4. In the practical application, NW60 and type A is considered to be the best combination of material and installation method. By this combination, the level of maximum heating load can be reduced at the rate of 43% for spring season and 40% for autumn season. 5. Another heating method, comparted heating, can be recommended to save the energy.

  • PDF