• Title/Summary/Keyword: current standard

Search Result 3,825, Processing Time 0.033 seconds

Implementation of Demo Program for Visual Communication in Compliance with MPEG-21 Part 22: User Description (MPEG-UD 표준을 준수하는 비쥬얼 커뮤니케이션 데모 프로그램 개발)

  • Lim, Hea-Jin;Choi, Jang-Sik;Jeon, Jin-Young;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.297-301
    • /
    • 2016
  • ISO/IEC JTC1/SC29WG11 MPEG has been standardizing UD(user description) to give a user personalized recommendation services. Besides, CD(context description), service description(SD), and recommendation description(RD) are recently being standardized by UD Adhoc Group in MPEG with an advanced UD to cope with needs of current and upcoming services such as augmented reality and social network. The descriptions was reflected to MPEG-UD WD(Working Draft) at MPEG $107^{th}$ meeting and the document was finally approved as international standard by national bodies with standard number(ISO/IEC IS 21000-22 UD) at $114^{th}$ MPEG meeting. In addition, reference software WD to validate conformance of UD standard was approved at $113^{th}$ MPEG meeting. In this paper, we developed a demo program for visual communication according to guideline defined in reference software WD to validate the reference software as well as UD standard.

Improvement Direction on the Assignment of Safety Managers in the Construction Site (건설안전관리자 선임기준의 개선방향 연구)

  • Kim, Ho Min;Woo, In Sung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In consideration of current circumstances which management activities for safety performance on construction sites are mostly controlled by safety personnel, it is necessary to maintain qualified safety personnel those who are experienced and have adequate ability. This is a major factor in order to prevent any of work related incident in the construction site. However, the existing standard which enforces certain number of safety personnel in the construction site aligning with respective contract amount could lead to difficulties for proactive safety management. So, it is required to get improvement on the existing standard. In nominating the proper number of safety personnel, it would be more efficient to consider the level of risk for characteristic of work itself and the total number of manpower mobilized in respective construction work, rather than to follow the existing standard of manpower ratio as per the contract amount. Hence, this study aims to propose several plans which enable to improve the existing standard for assignment of safety personnel on construction sites.

A Study of the Long-term Fuel Mix with the Introduction of Renewable Portfolio Standard (RPS(Renewable Portflio Standard) 제도 도입에 따른 국내 장기 전원구성 변화에 관한 연구)

  • Lee, Jeong-In;Han, Seok-Man;Kim, Bal-Ho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.467-477
    • /
    • 2009
  • Renewable Portfolio Standard (RPS) is a regulatory policy that requires the generation companies to increase the proportion of renewable energy sources such as wind, solar, LFG, fuel cell, and small hydro. Recently, Korean government decided to increase the portion of renewable energy to 3% to total electricity generation by 2012 from the current level of 0.13%. To achieve this goal, an innovative plan for market competitiveness would be required in addition to the present Feed-In-Tariff (FIT). That is Korean government has taken it into consideration to introduce a Renewable Portfolio Standard (RPS) as an alternative to FIT. This paper reviews the impact of RPS on the long-term fuel mix in 2020. The studies have been carried out with the GATE-PRO (Generation And Transmission Expansion PROgram) program, a mixed-integer non-linear program developed by Hongik university and Korea Energy Economics Institute. Detailed studies on long-term fuel mix in Korea have been carried out with four RPS scenarios of 3%, 5%, 10% and 20%. The important findings and comments on the results are given to provide an insight on future regulatory policies.

A Study on the Bayes Estimation Application for Korean Standard-Quality Excellence Index(KS-QEI) (베이즈 추정방식의 품질우수성지수 적용 방안에 관한 연구)

  • Kim, Tai Kyoo;Kim, Myung Joon
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.4
    • /
    • pp.747-756
    • /
    • 2014
  • Purpose: The purpose of this study is to apply the Bayesian estimation methodology for producing 'Korean Standard -Quality Excellence Index' model and prove the effectiveness of the new approach based on survey data by comparing the current index with the new index produced by Bayesian estimation method. Methods: The 'Korean Standard -Quality Excellence Index' was produced through the collected survey data by Bayesian estimation method and comparing the deviation with two results for confirming the effectiveness of suggested application. Results: The statistical analysis result shows that suggested estimator, that is, empirical Bayes estimator improves the effectiveness of the index with regard to reduce the error under specific loss function, which is suggested for checking the goodness of fit. Conclusion: Considering the Bayesian techniques such as empirical Bayes estimator for producing the quality excellence index reduces the error for estimating the parameter of interest and furthermore various Bayesian perspective approaches seems to be meaningful for producing the corresponding index.

The Electrical Characterization of the Quantized Hall Device with GaAs/AlGaAs heterojunction structure (GaAs/AlGaAs 이종접합된 양자흘 소자의 전기적 특성)

  • 유광민;류제천;한권수;서경철;임국형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.334-337
    • /
    • 2002
  • The Quantum Hall Resistance(QHR) device which consists of GaAs/AlGaAs heterojunction structure is used for the realization of QHR Standard based on QHE. In order to characterize electrical contact resistances and dissipations of the device, it is slowly cooled down for eliminating thermal shock and unwanted noise. Then, the two properties are measured under 1.5 K and 5.15 T. Contact resistances are all within 1.2 Ω and longitudinal resistivities are all within 1 mΩ up to DC 90${\mu}$A. The results mean the device is operated well to realize the QHR Standard. To confirm it, the QHR Standard having the device is compared using a direct current comparator bridge with a 1 Ω resistance standard which the calibrated value is known from QHR standards maintained by other countries. The difference between them is agreed well within measurement uncertainty. It is thus considered that the properties of the device is estimated well and has good performance.

  • PDF

A study on Actual Quantity of Shotcrete Sprayed in a NATM tunnel (NATM 산악터널의 숏크리트 투입율에 관한 연구)

  • Lee, Cheol-Ju;Kim, Sung-Yun;Kim, Dong-Gun;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.57-64
    • /
    • 2009
  • This study has analysed actual overbreak, shotcrete rebound and the ratio between the actual quantity of shotcrete to designed shotcrete measured during a NATM tunnel construction. The measured shotcrete rebound was about 7.2% in average which was about half the allowable rebound (15%), showing shotcrete spraying was performed well. Based on the measurement of excavated tunnel shape, average overbreak was about 28.5cm after tunnel excavation by drill and blasting method. This was about 260% of allowable overbreak. In addition, due to the rebound and overbreak actual amount of shotcrete used in the tunnelling work was about 116.5 % of the designed value. According to the field measurement the ratio of actual shotcrete to designed value showed some relation with standard support pattern, but the size of overbreak did not show the correlation with standard support pattern. Hence current design specifications stating the size of overbreak based entirely on standard support pattern should perhaps be reestablished. The insight into the design guideline regarding overbreak and shotcrete.

  • PDF

The current status and strategies of livestock health control on national and international basis (국내.외 가축위생관리기준의 현황, 적용과 대책)

  • Ryu, Il-Sun
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.240-272
    • /
    • 2009
  • Recently, as Foot and Mouth disease(FMD) outbreaks in South-East Asia, Taiwan, China, we cannot loose our tense to sustain our FMD free country status. And we have increasing possibility of disease inflow because of continual outbreaks of FMD type A, O and Asia 1 in neighbored countries, foreign visitor and foreign workers. So we have to be urgently ready for strengthen surveillance, early-report and early-diagnosis. So the most important things in epidemic control of livestock are co-work between central and local epidemic control office and field epidemic control. However, potential risk for FMD recurrence and sporadic occurrence of epidemic disease still threaten our livestock farmhouse, so we have to be ready for bio-security against these threatening. For these reasons, I will introduce the concept, etiology and epidemiology of disease and investment/ analysis of health management standard of main animals like cattle and pig which is applied to the inside and outside of country. With these references, we have to manage livestock health management thoroughly by establishing livestock health management standard and notifying special veterinarian and livestock farmer of these standard. Later on, prevention and quarantine of epidemic outbreak and establishing livestock health management standard should be undertaken primarily for sustainable growth and stability of livestock farm industry.

  • PDF

A Study on the Characteristics of Domestic Vehicle on the Roof Crush Test Considering the Enhanced Safety Standard, FMVSS 216 (북미 법규 강화를 고려한 국내 자동차의 천정강도 시험특성에 관한 연구)

  • Kim, Eun-Hee;Lee, Jae-Kwang;Lee, Moon-Gu;Hong, Min-Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.348-354
    • /
    • 2009
  • In order to reduce the risk of roll over crash, one of the greatest risk events, National Highway Traffic Safety Administration(NHTSA) issued Notice of Proposed Rulemaking(NPRM) enhancing the safety standard on roof crush resistance, FMVSS No. 216 and changing some part of the test procedure. According to this NPRM, the boundary Gross Vehicle Weight Rating(GVWR) of the vehicles applied by this standard is extended from 2,722kg(6000 lb) to 4,536 kg(10000 lb) and the applied test force is increased from 1.5 times to 2.5 times of Unloaded Vehicle Weight (UVW). Also the current limit on the amount of roof crush, 127mm(5 inch), is replaced with a new requirement of maintaining enough headroom without touching the head of a seated 50% male dummy. In this paper, we carried out the rollover crash test on some domestic cars and investigated their safety due to the KMVSS No. 92 and the enhanced safety standard, FMVSS No. 216, respectively. The result shows that most of them can satisfy the new standards but further tests will be necessary, especially for heavier cars.

  • PDF

CURRENT RESEARCH AND DEVELOPMENT ACTIVITIES ON FISSION PRODUCTS AND HYDROGEN RISK AFTER THE ACCIDENT AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION

  • NISHIMURA, TAKESHI;HOSHI, HARUTAKA;HOTTA, AKITOSHI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • After the Fukushima Daiichi nuclear power plant (NPP) accident, new regulatory requirements were enforced in July 2013 and a backfit was required for all existing nuclear power plants. It is required to take measures to prevent severe accidents and mitigate their radiological consequences. The Regulatory Standard and Research Department, Secretariat of Nuclear Regulation Authority (S/NRA/R) has been conducting numerical studies and experimental studies on relevant severe accident phenomena and countermeasures. This article highlights fission product (FP) release and hydrogen risk as two major areas. Relevant activities in the S/NRA/R are briefly introduced, as follows: 1. For FP release: Identifying the source terms and leak mechanisms is a key issue from the viewpoint of understanding the progression of accident phenomena and planning effective countermeasures that take into account vulnerabilities of containment under severe accident conditions. To resolve these issues, the activities focus on wet well venting, pool scrubbing, iodine chemistry (in-vessel and ex-vessel), containment failure mode, and treatment of radioactive liquid effluent. 2. For hydrogen risk: because of three incidents of hydrogen explosion in reactor buildings, a comprehensive reinforcement of the hydrogen risk management has been a high priority topic. Therefore, the activities in evaluation methods focus on hydrogen generation, hydrogen distribution, and hydrogen combustion.

Circuit design of an RSFQ counter for voltage standard applications (전압 표준용 RSFQ counter회로의 설계)

  • 남두우;김규태;김진영;강준희
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.127-130
    • /
    • 2003
  • An RSFQ (Rapid Single Flux Quantum) counter can be used as a frequency divider that was an essential part of a programmable voltage standard chip. The voltage standard chip is composed of two circuit parts, a counter and an antenna Analog signal of tens to hundreds ㎓ may be applied to a finline antenna part. This analog signal can be converted to the stream of SFQ voltage pulses by a DC/SFQ circuit. The number of voltage pulses can be reduced by 2n times when they pass through a counter that is composed of n T Flip-Flops (Toggle Flip-Flop). Such a counter can be used not only as a frequency divider, but also to build a programmable voltage standard chip. So, its application range can be telecommunication, high speed RAM, microprocessor, etc. In this work, we have used Xic, WRspice, and L-meter to design an RSFQ counter. After circuit optimization, we could obtain the bias current margins of the T Flip-Flop circuit to be above 31% Our RSFQ counter circuit designs were based on the 1 ㎄/$\textrm{cm}^2$ niobium trilayer technology.

  • PDF